Laserfiche WebLink
I I <br /> STOREFRONT VERTICAL STOREFRONT HORIZONTAL <br /> MULLION MULLION <br /> 5865 Owens Drive <br /> Pleasanton, CA 94588 <br /> 925-251-7200 <br /> GLAZING <br /> GLAZING— n�x <br /> SCALE: 3"=1'-0" SCALE: 3"=1'-0" <br /> TYPICAL STOREFRONT VERTICAL MULLION 10 TYPICAL STOREFRONT HORIZONTAL MULLION 5 CONSULTANT <br /> GYP.BD.M U MOLDING,PAINT <br /> BACKER ROD&SEALANT,TYP. <br /> STOREFRONTJAMB <br /> CEMENT PLASTER- PLASTER <br /> SEE SPEC. SCREED ELEvEn <br /> 0 <br /> FOR FRAMING S.S.D. SEALANT <br /> TYPE X GYP.BD. METAL FRAME <br /> SHEATHING <br /> AT JAMB <br /> STOREFRONT VERTICAL GLAZING <br /> FRAME TO J MOLD <br /> LAP BARRIER o/GSM <br /> DOOR FLASHING AT HEAD(WRAP 7-11 #1043581 <br /> ti <br /> GLAZING FELT INTO JAMB) <br /> Lul I <br /> �i <br /> CEMENT PLASTER W/J-MOLD SEALANT <br /> METAL FRAME PRIMED&PAINTED- N <br /> 2 LAYERS BLDG PAPER SEE DOOR SCHEDULE A7.1 SERIES <br /> HM DOOR-SEE DOOR VARIES <br /> PLYWOOD SHEATHING SCHEDULE A7.1 SERIES <br /> WEATHERSTRIPPING <br /> 115/16"AT13/4"DOORS NOTE: SEE DETAIL(11 /A9.2) <br /> 19/16"AT 13/8"DOORS FOR TYPICAL OPENING <br /> SCALE: 3"=1'-0" SCALE: 3"=1'-0" SCALE: 3"=1'-0" AT HEAD FLASHING z w <br /> w <br /> TYP EXT SF JAMB @ CEMENT PLASTER 14 TYPICAL EXTERIOR STOREFRONT DOOR @ JAMB 9 EXT HM DOOR FRAME @ HEAD & JAMB_1 HR WALL. 4 O <br /> Cn c/' <br /> GYP.BD. <br /> GYP.BD. <br /> PLYWOOD SHEATHING 06 <br /> PLYWOOD SHEATHING DOOR SEE DOOR SCHEDULE z <br /> 2 LAYERS WEATHER RESISTANCE BARRIERFLOOR FINISH PER PLANS Q U <br /> ,. 2 LAYERS BLDG.PAPER 0 <br /> 1 i THRESHOLD,SET IN BED OF SEALANT <br /> THIN BRICK VENEER — i PROVIDE COMPLETE SEPARATION BETWEEN CNz <br /> CEMENT PLASTER WI J MOLD i CONC.&THRESHOLD <br /> 06 0 <br /> DRIP WHERE INDICATED <br /> FRAMING,SEE A2.1, "; i <br /> S.S.D. <br /> FRAMING,SEE A2.1, EXPANSION JOINT O J <br /> i S.S.D. XX <br /> N Q <br /> i SLOPE: <br /> DRIP CREED i i i 118"11T MIN Z <br /> �" a <br /> Ld <br /> - - - - - - - - - - - - - �' RECESSED SLAB WHERE - ° d <br /> GAV.BRAKE METAL.PAINT TO MATCH )O� O(( - INDICATED cn <br /> o <br /> THIN BRICK BRK-1 COLOR <br /> BACKER ROD&SEALANT ° ° <br /> SHEET MEMBRANE FLASHING )O (( a EXTERIOR ° INTERIOR od <br /> HARDSCAPE SLAB,-' <br /> STOREFRONT HEAD . <br /> BACKER ROD&SEALANT,TYP.EA.SIDE <br /> CONC SLAB-SSD <br /> STOREFRONT HEAD GLAZING <br /> GLAZING <br /> SCALE: 3"=1'-0" SCALE: 3"=V-0" SCALE: 3"=1'-0" <br /> S.F. HEAD AT THIN BRICK 13 TYP EXT STOREFRONT HEAD 8 TYPICAL EXTERIOR HM DOOR THRESHOLD 3 <br /> P R#2 01 .06.2020 <br /> SQUARE&LEVEL <br /> FRAMING <br /> GLAZING <br /> WALL SHEATHING HEADER HEADER X REVISIONS <br /> (WHERE OCCURS) <br /> STOREFRONT SILL _ SHALL HAVE EDGES ROUGH IN <br /> GLAZING FLUSH WIFRAME OPENING JAMB FLASHING <br /> BACKER ROD&SEALANT OPENING OPENING SILL FLASHING <br /> EXTEND JAMB <br /> GSM PAN FLASHING,PAINT TO FLASHING <br /> MATCH THINK BRICK BRK-1 COLOR - - - - - - - - - - - - SILL FLASHING BEYOND SILL <br /> BACKER ROD&SEALANT i STOREFRONT DOOR FLASHING <br /> i HEAD O FIGURE A FIGURE B HEAD FLASHING <br /> SHAPED TOP PLATE UNDER BUILDING <br /> i PAPER <br /> I _ <br /> THIN BRICK VENEER i DOOR HEADER EXTEND JAMB <br /> i JAMB FLASHING FLASHING <br /> 2 LAYERS WEATHER i ❑ APPLY CONTINOUS OPENING % / BEYOND SILL <br /> RESISTIVE BARRIER i SEALANT BEAD TO / WDW.' FLASHING <br /> i PERIMETER OF SILL FLASHING / FRAME <br /> PLYWOOD SHEATHING, - OPENING _ / APPLY CONTINOUS <br /> SEALANT BEAD <br /> i <br /> WHERE OCCURS GLAZING,SEE ALONG TOP <br /> - <br /> i SCHEDULE MOUNTING FLANGE <br /> GYP.BD.WI METAL i FIGURE C SILL FLASHING OVER FIGURED OR G.S.M.FLASHING. <br /> CLOSURE,PAINT i BUILDING PAPER EMBED HEAD <br /> FLASHING INTO <br /> FLASHING:GRACE VYCOR PLUS OR SEALANT <br /> FRAMING,S.S.D. i APPROVED EQUAL <br /> i FLASHING OF EXTERIOR WALL OPENINGS <br /> SCALE: 3"=1'-0" SCALE: 3"=1'-0" <br /> INDIVIDUALLY FLASH ALL EXTERIOR OPENINGS FOR FIXTURES SUCH AS WINDOWS,DOORS,AND VENTS TO MAKE THEM WATER <br /> TIGHT.PENETRATION FLASHING MATERIAL SHALL BE COATEDUR MIN. <br /> S.F. SILL AT THIN BRICK 12 TYPICAL STOREFRONT DOOR HEAD @ TRANSOM 7 PROTECTION FROM WATER PENETRATIIONWHENTESTEDRIER INAC ORDANCEIWITTNFOHASTDMD-779.SEALANNTAND SHALLISDHALILOCOMPLY TOFFTT- <br /> S-1657. IN HIGH WIND AREAS A WATERPROOF SHEET MEMBRANE SHALL BE USED OVER SOLID BACKING. <br /> FOR NAIL-ON-FLANGE TYPE FIXTURES A STRIP OF APPROVED FLASHING MATERIAL SHOULD BE AT LEAST 9"WIDE. FLASHING <br /> SHALL BE APPLIED IN A WEATHERBOARD FASHION AROUND THE FULL PERIMETER OF THE OPENING. <br /> APPLY THE FIRST STRIP HORIZONTALLY IMMEDIATELY BELOW THE SILL,CUT IT SUFFICIENTLY LONG TO EXTEND PAST EACH SIDE <br /> OF THE WINDOW,SO THAT IT PROJECTS BEYOND THE VERTICAL FLASHING TO BE APPLIED LATER. FASTEN THE TOP EDGE OF <br /> THE SILL FLASHING TO THE FRAMING,BUT DO NOT FASTEN THE LOWER EDGE,SO THE WEATHER-RESISTIVE BARRIER APPLIED <br /> GLAZING STOREFRONT DOOR,SEE LATER MAY BE SLIPPED UP AND UNDERNEATH THE FLASHING IN WEATHERBOARD FASHION. (SEE FIGURE A) <br /> SCHEDULE,A7.1 SERIES <br /> NEXT,FASTEN STRIPS OF FLASHING AT EACH VERTICAL EDGE(JAMB)OF THE OPENING.RUN THIS FLASHING BEYOND THE SILL <br /> FLASHING AND ABOVE WHERE THE HEAD FLASHING WILL INTERSECT.(SEE FIGURE B) <br /> APPLY A CONTINUOUS SEAL TO THE BACKSIDE(INTERIOR)OF THE MOUNTING FLANGE NEAR THE OUTER EDGE OR A SEAL/SIGNATURE <br /> CONTINUOUS SEAL TO THE PERIMETER OF THE OPENING AT A POINT TO ASSURE CONTACT WITH THE BACKSIDE(INTERIOR)OF <br /> MTL.THRESHOLD SET IN 3 BEADS OF THE MOUNTING FLANGE.(SEE FIGURE C) JOB NO. 1497.009 <br /> SEALANT PROVIDE COMPLETE <br /> STOREFRONT SILL SEPARATION BETWEEN CONC.& FOR FIXTURES WITH OUT A NAIL-ON-FLANGE THE FLASHING SHALL BE 12"MIN.WIDE AND EXTEND INTO THE ROUGH FRAME AT <br /> THRESHOLD 1 THE SILL AND JAMB IN A WEATHERBOARD FASHION. DRAWN J K <br /> BACKER ROD&SEALANT <br /> _ _ _ THE FIXTURE SHALL THEN BE INSTALLED. CHECK GM <br /> 030 ALUM PAN SILL,PAINT TO ° ° SLOPE: `s <br /> ° °`= = 118"112"MIN. NEXT,APPLY A CONTINUOUS SEAL AT THE TOP(HEAD)MOUNTING FLANGE OR G.S.M.HEAD FLASHING AND EMBED THE BOTTOM <br /> MATCH SF <br /> ° . _-° a - , - d' _ a_a, , ; '•.° ° d - d' a ° " , OF THE HEAD FLASHING OVER THE SEALANT AND THE MOUNTING FLANGE OR G.S.M.FLASHING.CUT THIS FLASHING ARCHITECTURAL�+ <br /> SILL SET IN 3 CONT.BEADS OF a - °;' °" ° , b °° �, ° - SUFFICIENTLY LONG SO THAT IT WILL EXTEND BEYOND EACH JAMB FLASHING. FASTEN IN PLACE.(SEE FIGURE D) DETAILS - EXTERIOR <br /> SEALANT AT BUILDING SLAB N d <br /> 4,d °;-d o a ° ao- ° ; APPLY REMAINING WEATHER-RESISTIVE BARRIER IN A WEATHERBOARD FASHION WITH THE SILL FLASHING LAPPING OVER THE STOREFRONT AND <br /> a HARDSCAPE SLAB CONC SLAB° b - TOP,AND THE HEAD AND JAMB FLASHING BELOW. <br /> °.,4 <br /> 00 a4 <br /> ° OPENNINGS <br /> � � :4 <br /> ° ° • BASED UPON INDUSTRY STANDARDS APPROVED BY THE CALIFORNIA ASSOCIATION OF WINDOW MANUFACTURERS,(CAWM). <br /> N <br /> - SHEET <br /> SCALE: 3"=1'-0" SCALE: 3"=1'-0" <br /> 0 <br /> N <br /> co TYPICAL EXTERIOR STOREFRONT SILL 11 TYPICAL EXTERIOR STOREFRONT DOOR SILL 6 FLASH IN AT EXTERIOR WALL OPENINGS 1 A 02 <br />