Laserfiche WebLink
4" 112"MIN. BASE OF UNIT EXTENDS 112"MIN. <br /> PREFAB.ROOF SCUTTLE WI WD. G.S.M.FLASHING FLANGE BEYOND&OVER TOP OF CURB <br /> NAILER AT PREFAB CURB,SEE SOLDER ALL SEAMS <br /> SPECIFICATIONS o SLOPE TOP 118"PER 12" 4° MECHANICAL UNIT,S.M.D. <br /> CONTINUOUS ISOLATOR PAD/SEAL <br /> G.S.M.FLASHING COLLAR,SEE SPECIFIC 2 PIECE SPRINGLOK COUNTER- <br /> APPLICATION DETAIL FOR FURTHER INFO. <br /> ° FASTENERS AT 12"O.C. <br /> 11 FIBER CANT FLASHING FIN AT WOOD MEMBERS,SEE 1 <br /> o c STRIP SPECIFIC APPLICATION DETAIL / 2 X 4 NAILER <br /> A9.3 <br /> SIM. G.S.M.COUNTER FLASHING WI PREFAB.UNIT MOUNTING CURB,S.M.D. <br /> FASTENERS AT 8"O.C. PVC SPEPVCC.00F,SEE <br /> _7o INSULATION <br /> ACCESS LADDER SEE _ \ M ' // \\ = BONDING ADHESIVE <br /> DETAIL(23/A9.3) °° RECTANGULAR , _ <br /> Y SINGLE PLY ROOFING 5865 Owens Drive <br /> - - DRIP/INTERLOCK 4„ M Pleasanton, CA 94588 <br /> 925-251-7200 <br /> 1 X 4 AROUND <br /> OPENING q G.S.M.FLASHING FLANGE 4„ CONTINUOUS WELD,1 112"MIN. <br /> 114"X 3"W BENT FOR SOLDER ALL SEAMS CUT-EDGE SEALANT <br /> PLATE FRAMING <br /> S.S.D. G.S.M.FLASHING COLLAR,SEE SPECIFIC <br /> FOR FINISH SEE APPLICATION DETAIL FOR FURTHER INFO. <br /> Z ELEV.Lu <br /> ROUND LINE OF ROOF DECKING MATERIAL SEE ROOF PLAN <br /> FOR MORE INFORMATION <br /> 0 <br /> SEE PLANS FOR SPECIFIC PENETRATION SIZE <br /> SCALE: 1"=1'-0" SCALE: 1"=V-0" SCALE: 3"=1'-0" FOR FRAMING,S.S.D. <br /> ROOF HATCH 15 TYP. PENETRATION FLASHING 10 PREFAB. MECH. UNIT CURB 5 CONSULTANT <br /> FACTORY SWAGE FOR LAP ELASTOMERIC SEALANT <br /> BY ADJACENT LENGTH 6„ <br /> OF REGLET LAP WALL GRADE'D'WEATHER- DUCT,S.M.D. <br /> RESISTIVE BARRIER 01 G.S.M.WALL 22 GA.,MIN.,G.S.M.COUNTERFLASHING <br /> MTL REGLET- 60" FLASHING BOOT <br /> FACTORY FABRICATED 22 GA.,MIN.,G.S.M.FLASHING - <br /> (V <br /> OUTSIDE CORNER BY SOLDER ALL SEAMS HIGH DOMED,CAPPED,GASKETED <br /> FRY REGLET W7— <br /> SLOPE _ <br /> LAP SELF-ADHERED W.P.MEMBRANE OVER FASTENERS AT 18"O.C. <br /> ADJACENT COUNTERFLASHING LAPPED G.S.M.FLASHING BOOT,AT WALL/PARAPET REMOVEABLE,22 GA.MIN., ELEVEn <br /> BY LEGS OF OUTSIDE CORNER 6" INTERSECTION G.S.M.COUNTERFLASHING <br /> FASTENERS AT 8"O.C. <br /> MTL FLASHING EXTEND LEG TO TOP OF CANT STRIP OR 12" <br /> FACTORY-FABRICATED MIN.,&01 WALL FELTS 0.045 EPDM,COVER TOP EDGE <br /> OUTSIDE CORNER BY OF FLASHING <br /> FRY REGLET(EXTENT <br /> SHOWN DASHED) 6" PARAPET AT WALL RIPPED 2 X z 7-11 #1043581 <br /> FACTORY NOTCH TO ACCEPT 6" FASTENER WI PLATE,12"O.C. <br /> DRIP FLANGE OF LAPPING 6" -LAP ROOF FELT 01 G.S.M.WALL °° <br /> COUNTERFLAS FLASHING BOOT CONTINUOUS WELD,1 1/2"MIN. <br /> NOTE: SOLDER ALL SEAMS CUT-EDGE SEALANT <br /> 1. SEE PLANS FOR ACTUAL REGLET \ <br /> TYPE. TYPE SURFACE-MOUNT(SM) \ LAP SELF-ADHERED W.P.MEMBRANE SINGLE-PLY ROOFING <br /> SHOWN FOR CLARITY OVER G.S.M.FLASHING BOOT,AT WALL/ <br /> 2. REGLETS SHALL BE BY FRY PARAPET INTERSECTION <br /> REFERS TO <br /> REGLET,U.O.N. 07075504 <br /> SCALE: 3"=1'0" PARAPET AT ROOF SEE PLANS FOR FRAMING w <br /> SCALE: 1"=1'-0" SCALE: 3"=1'-0" <br /> w <br /> REGLET - OUTSIDE CORNER 14 PARAPET FLASHING BOOT 9 DUCT PENETRATION 4 0 1- <br /> PATHWAME. 0707s007.dwg U) <br /> 6" r LAP WALL GRADED WEATHER-RESISTIVE <br /> 3". 1' <br /> 6 BARRIER OIWALL FLASHING MTL REGLET- CCQ U <br /> 318"DIA.LAG SCREWS OR MACHINE BOLTS 6 � <br /> FACTORY-FABRICATED PRE-MOLDED OUTSIDE CORNER G z <br /> 6 INSIDE CORNER BY FRY BEFORE INSTALLATION w <br /> 1/4"X 3"BENT STEEL PLATE AT 4'-0"O.C.MAX. SOLDER ALL SEAMS REGLET O <br /> 3/4"DIA.STEEL RUNGS WI NON SLIP FINISH AT PLAN 6" SNAP ON G.S.M.COPING FACTORY SWAGE FOR LAP BY L�� �� WATER CUT-OFF MASTIC z V <br /> 12"O.C.WELDED TO 1/4"PLATE OIEND CAP FLASHING WI 318 - ADJACENT LENGTH OF REGLET e� < STAINLESS STEEL CLAMPING U <br /> x 1116 BUTYL WATER RING 0 <br /> J BARRIER STRIPS <br /> 114"X 3"STEEL PLATE GRAVEL STOP WITH CLEAT TO CLIP MTL FLASHING- OUTSIDE CORNER MFR'S PRE MOLDED ^I <br /> < <br /> � PIPE FLASHING ` V <br /> 4X SOLID BLOCKING AT WOOD OVER FLASHING - \ FACTORY-FABRICATED Z <br /> EXTEND LEG TO TOP OF CANT <br /> INSIDE CORNER BY FRY CONTINUOUS WELD,1 112"MIN. 06 0 <br /> STUDS OR 4"X18 GA.STAP AT \ REGLET(EXTENT SHOWN BEYOND FASTENING PLATES (n <br /> METAL STUDS STRIP OR 12"MIN. \ DASHED) J <br /> FOR FRAMING S.S.D. Q <br /> PARAPET AT WALL EAVE FLASHING SINGLE PLY ROOFING <br /> FOR FINISH SEE ELEVATION 6 ,F ADJACENT COUNTERFLASHING <br /> 1/4"X 3"STEEL PLATE \6, AT WALL LAPS LEGS OF INSIDE CORNER STRUCTURAL ROOF <br /> 314"DIA.STEEL RUNGS WI NON q LAP ROOF FELT 01 ROOF z <br /> SLIP FINISH AT 12"O.C.WELDED `0i FLASHING FACTORY NOTCH ACCEPT <br /> )� DRIP FLANGE OF LAPPING <br /> TO 1/4"PLATE SOLDER ALL SEAMS COUNTERFLASHING BLOCKING <br /> I <br /> 318"DIA.X 4"EXPANSION -— - - INSTALL OUTSIDE CORNERS PER DIAGRAM CONTINUOUS PIPE, <br /> ANCHOR NOTE: ABOVE 314"MIN.-8"MAX., <br /> S.P.D.&S.E.D. <br /> SNAP ON G.S.M.COPING O/END CAP 1. SEE PLANS FOR EXACT REGLET TYPE. USE ONE CONTINUOUS SHEET OF SINGLE-PLY <br /> SOLID SLAB NG 3 o FLASHING W/3/8"X 1116"BUTYL TYPE SURFACE-MOUNT(SM)SHOWN FOR ROOFING TO WRAP AROUND CURB <br /> SOLID BEARING WATER BARRIER STRIPS <br /> CLARITY <br /> SL 2. REGLETS BY FRY REGLET(U.O.N.) USE MANUFACTURER'S JOINT COVER AT <br /> FRONT a SIDE PARAPET AT ROOF FUORTHERENFO AIL(9/ 9. ) OR <br /> A 3 F INTERSECTIONS BETWEEN SPLICES <br /> SCALE: 1"=V-0" — - SCALE: 1"=V-0' SCALE: 3"=1'-0" SCALE: 3"=V-0" SCALE: 3"=1'-0" <br /> ROOF ACCESS LADDER 23 PARAPET 18 REGLET-INSIDE CORNER 13 TYPICAL ROOF FLASHING OUTSIDE CORNER 8 ROOF PENETRATION 3 <br /> 0707s034.dwg yzeng 0707s006.dwg 10/18/2006 3:58 PK I PR#2 01 .06.2020 <br /> 318"X 1116"BUTYL WATER BARRIER i EXTERIOR FINISH PER WALL SECTION "SM"REGLET WATER CUT-OFF MASTIC <br /> WALL FRAMING,S.S.D. 24tij N, 1 i <br /> STRIPS EACH SIDE OF JOINT GRADE D WATER RESISTIVE BARRIER STAINLESS STEEL CLAMPING <br /> ` i i 1"LAP JOINT RING <br /> 2X BLKG. CONCEALED JOINT COVER AT 10'0"MAX. SHEATHING WHERE OCCURS SEALANT (REGLET) q s� a MFR'S PRE MOLDED REVISIONS <br /> STRUCTURAL COLUMN WHERE i 2 X 4 SOLID BLK'G.AT WOOD STUDS OR Q PIPE FLASHING <br /> OCCURS,S.S.D. SNAP ON G.S.M.COPING ��\ 4"X 18 GA.STRAP AT METAL STUDS EXPANSION COUNTER- N o <br /> SLOT FLASHING U- CONTINUOUS WELD,1 112 MIN. <br /> 2-PIECE SPRINGLOK COUNTERFLASHING o BEYOND FASTENING PLATES <br /> PARAPET COPING SEAM SYSTEM TYPE ST,BY FRY REGLET <br /> (818)237-9773,OR EQUAL 3"LAP JOINT ® CUT EDGE SEALANT <br /> 112"GYP.BD.FIRE BLOCK,OR i (COUNTER <br /> OTHER APPROVED MATERIAL AS MITER PARAPET COPING AT �. FLASHING) SINGLE-PLY ROOFING <br /> CORNERS&SOLDER JOINTS 518"CDX PLYWD.SPACER <br /> PER C.B.C.SECTION 717.2.1 tie i ��,� <br /> 318"X 1116"BUTYL WATER BARRIER <br /> STRIPS TOP&BOTTOM ' <br /> FIRE-SAFE JOINTS AS i 6"�YBLOCKING <br /> u:) BASE FLASHING <br /> REQUIRED TO FILL JOINTSN¢ <br /> (TYP•) STRUCTURAL ROOF <br /> y ¢w G.S.M. ROOF MEMBRANE <br /> 2X4 JSTS.MIN.,AT '`n FLASHING <br /> 24"O.C.MAX. SHEATHING S.S.D.I Z CONTINUOUS PIPE <br /> CONT.2X4 AT RIM — — — — — — — NOTE: <br /> N — � 1. SEE PLANS FOR __1KICKER S.S.D. ACTUAL REGLET TYPE. — <br /> NOTE:ALL CONSTRUCTION SHALL COMPLY WITH 2010 C.B.C.SECTIONS 709.4 AND 717 �) REGLET TYPE"SM" <br /> SOFFITS AND OTHER SIMILAR CAVITIES SHALL BE OF SIMILAR CONSTRUCTION. SHOWN FOR CLARITY. PRE-MOLDED PIPE FLASHING <br /> FIRESTOP SHALL OCCUR AT 10'-0"INTERVALS BOTH HORZONTALLLY&VERTICALLY AT SOLDER ALL SEAMS Q OTHER REGLETS SIM. <br /> CEILING AND FLOOR LEVELS,BETWEEN FLOORS,&AT WALL TO ROOF CONDITIONS. "ro 2. REGLETS BY FRY <br /> ALTERNATIVE MATERIALS AND METHODS OF FIRESTOPPING MAY BE USED WHEN PARAPET AT � \ REGLET,U.O.N. WELD ENTIRE WIDTH OF FLASHING — <br /> APPROVED BY THE LOCAL CODE AUTHORITY. OVERLAP <br /> PARAPET AT CORNER VERTICAL CHANGE <br /> SCALE: 1"=1'-0" SCALE: 1"=1'-0" \ SCALE: 1"=1'-0" SCALE: 3"=V-0" <br /> TYP. CAVITY FIRE BLOCK 22 PARAPET COPING 17 \ PVC ROOFING REGLET LAP JOINT 7 ROOF PENETRATION 2 <br /> APPLICATION NOTES FOR LOW SLOPE,3:12 TO LESS THAN 4:12: <br /> 1. START WI 1-19"WIDE SHEET OF FELT ALONG EAVE WI 318"OVERHANG. 6" OPTIONAL FLANGE LOCATION, THE HOLE IN THE MEMBRANE SHALL EXCEED THE DIAMETER OF <br /> 2. TROWEL A CONTINOUS LAYER OF ROOFING CEMENT(AT A RATE OF 2 GALLONS PER 100 SQ.FT.)ON TO THE FELT. 1 VERIFY WALL WIDTH 1 THE DRAIN PIPE,BUT SHALL BE NO LESS THAN 112"FROM THE R.D. = ROOF DRAIN <br /> 3. PRESS 1-36"WIDE SHEET OF FELT FIRMLY ONTO THE CEMENT,&NAIL DOWN WITH GALV.ROOFING NAILS AT 12"O.C. 6" ATTACHMENT POINTS OF THE DRAIN CLAMPING RING. <br /> ALONG A LINE 18"ABOVE THE BTM.EDGE OF THE FELT. 6" 2 \ O.F. = OVERFLOW DRAIN <br /> 4. APPLY ROOFING CEMENT TO THE UPPER 19"OF THE EXPOSED FELT. 2 <br /> 5. COVER THE CEMENTED PORTION WI THE NEXT SHEET OF FELT&NAIL. ALL BOLTS OR CLAMPS MUST BE IN PLACE TO PROVIDE CONSTANT <br /> 6. REPEAT PROCESS UNTIL 24"INSIDE THE INTERIOR WALL LINE. 6" COMPRESSION ON WATER CUT-OFF MASTIC. <br /> 7. COVER THE REMAINING ROOF WI DBL.LAYERS OF FELT,W/O CEMENT,UP TO THE RIDGE. J <br /> 6"OVERLAP AT VALLEYS.INTERLACE ALL PILES,CROSSING FOR FULL COVERAGE. HIPS SIM. STRUCTURAL ROOF <br /> FULL 36"WIDE FELT DOWN CENTER OF VALLEY OVER FELT UNDERLAYMENT <br /> 4 <br /> ——————— ———————— <br /> WALL LINE SEAL/SIGNATURE <br /> — — —— <br /> 6"MIN END LAP 3 6 2X6 BLOCKING BETWEEN (t' STRAINER +0"EL 2"EL o <br /> FACE OF FINISH 2"MIN HEAD LAP TRUSSES CLAMPING RING TAPERED EDGE STRIPS - JOB NO. 1497.009 <br /> SLEEVE AT SCREW ATTACHMENT FILLROOF DECK 3 R.D. <br /> SOLID WI SEALANT PRIOR TO _ <br /> INSTALLATION OF SCREW FELT UNDERLAYMENT �. 6 SINGLE PLY ROOFING o <br /> .1' <br /> 6"OVERLAP -: ; . �-. OVERFLOW DRAIN j <br /> - DRAWN JK <br /> �\ LIGHTWEIGHT <br /> WHERE OCCURS PERFORMED CANT o l'-9"U.O.N. CHECK GM <br /> GSM DOWNSPOUT AT RIDGE j 4 2 \ INSULATING CONCRETE - <br /> �' \'V <br /> HANGERS w - N z o - <br /> l." <br /> GSM DOWNSOUT <br /> METAL SIDE DRIP �: :`, 1Y LAP WALL HE I TIVE b '� � � O.F ARCHITECTURAL <br /> 1 <br /> 9 � <br /> EDGE OVER FELT �. GRADE'D'WEAT R-RES S BARRIER 01 Q DRAINAGE SUMP <br /> WALL FLASHING " DETAILS - ROO F <br /> G.S.M.FLASHING WI DRIP N <br /> GSM DOWNSPOUTS SEE SMACNA GUIDE SECTION 1.76 FIGURE 1-35 EDGE OR GUTTER WING .. 2. SOLDER ALL SEAMS NOTES: - <br /> 3. SNAP ON G.S.M.COPING OIEND CAP FLASHING W/3/8"X 1. LAP ADJACENT LENGTHS OF WATER CUT OFF n O.F. <br /> ROOFING NAILS 1116"BUTYL WATER BARRIER STRIPS <br /> MASTICI <br /> C <br /> - � <br /> EP INSULATION BOARD <br /> "ST REGLET 1 . <br /> cam ; %, 4. EXTEND LEG TO TOP OF CANT STRIP OR 12"MIN. 2. LAP ADJACENT LENGTHS OF <br /> EAVE METAL EDGE UNDER FELT ROOF SHEATHING <br /> N / �,� 5. SEE DETAIL (9/A9.3)R FURTHER INFO. 2 COUNTERFLASHING 3"' 2X4 PLAN VIEW OF DRAIN <br /> o DETAIL SIM.AT ROOF WI 2X �� <br /> N BOOSTER AT EAVE ; <br /> DECK CLAMP SUMP SHEET <br /> O318"OVERHANG AT EAVE SEE PLANS FOR OTHER INFO. ROOF DRAIN <br /> SCALE: 3"=1'-0" SCALE: 11/2" 0-1- SCALE: 1"=V-0" SCALE: 3"=1' "=1'-0" <br /> 0 <br /> N <br /> DOWNSPOUT 20 FELT UNDERLAYMENT1 21 PARAPET COPING/FLASHING AT WALL 16 REGLET 11 ROOF DRAIN & OVERFLOW W/ SUMP 1 <br /> 0704S901 0707s035.dwg <br />