My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1515
>
1600 - Food Program
>
PR0546273
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2021 8:53:41 AM
Creation date
2/17/2021 4:21:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546273
PE
1615
FACILITY_ID
FA0026203
FACILITY_NAME
7 ELEVEN 38877A
STREET_NUMBER
1515
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1515 E MAIN ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
257
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL GENERAL NOTES: ELECTRICAL LEGEND <br /> 1. DO NOT SCALE THESE DRAWINGS; REFER TO LARGEST SCALE SYMBOL DESCRIPTION ABBREVIATIONS <br /> ARCHITECTURAL PLANS. $ SINGLE POLE WALL SWITCH <br /> 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE NOT INTENDED TO 2 A AMP <br /> SHOW MINOR DETAILS AND EXACT LOCATIONS. DESIGN ADJUSTMENTS $ WALL SWITCH - DESIGNATIONS AS FOLLOWS: AC ABOVE COUNTER <br /> SHALL BE ANTICIPATED BY THE CONTRACTOR TO PROVIDE A COMPLETE 2=2 POLE 4=4-WAY AFF ABOVE FINISHED FLOOR <br /> AND OPERATIONAL SYSTEM. 3=3-WAY P=PILOT LIGHT AFC AVAILABLE FAULT CURRENT <br /> 3. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH M=MOTOR RATED SWITCH H=LIGHTED HANDLE AFG ABOVE FINISHED GRADE <br /> CEC/NFPA 70. CONTRACTOR SHALL NOTIFY ENGINEER REGARDING ANY DM=DIMMER T=TIMER (REFER TO PLANS) AIC AMPS INTERRUPTING CURRENT <br /> CODE DISCREPANCIES SHOWN ON PLAN. ANY PERMIT OR INSPECTION BRKR BREAKER <br /> FEES ARE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. OS WALL TYPE OCCUPANCY SENSOR - LEVITON MODEL#OSSMT-MDW C CONDUIT <br /> 4. CONTRACTOR SHALL INSTALL GROUND AND BOND SYSTEM PER NEC. EC ELECTRICAL CONTRACTOR 5865 Owens Drive <br /> 5. CONTRACTOR SHALL COORDINATE TELEPHONE AND DATA OUTLETS OS CEILING TYPE OCCUPANCY SENSOR EM,EMER EMERGENCY Pleasanton, CA 94588 <br /> REQUIRED WITH OWNER PRIOR TO GYP BOARD BEING INSTALLED. EXIST,EX EXISTING 925-251-7200 <br /> 6. CONDUCTORS SHALL BE TYPE THHN, THWN, OR THW. BRANCH CIRCUIT SIMPLEX RECEPTACLE - NEMA 5-20R UNLESS NOTED OTHERWISE G GROUND <br /> CONDUCTORS SHALL NOT BE SMALLER THAN#12 AWG IN 3/4"C EXCEPT GFCI GROUND FAULT CIRCUIT INTERRUPTER <br /> WHERE SPECIFICALLY NOTED OTHERWISE. HOME RUNS ORIGINATING DUPLEX RECEPTACLE - NEMA 5-20R UNLESS NOTED OTHERWISE IG ISOLATED GROUND <br /> MORE THAN 80'AT 120V FROM PANEL LOCATION SHALL BE#10 AWG K KELVIN <br /> MINIMUM. WIRE#10 AWG AND SMALLER SHALL BE SOLID; WIRES#8 AWG 4 DOUBLE-DUPLEX RECEPTACLE - NEMA 5-20R UNLESS NOTED OTHERWISE NL NIGHT LIGHT <br /> AND LARGER SHALL BE STRANDED. PROVISIONS OF WIRE COLOR CODE GFCI MCB MAIN CIRCUIT BREAKER <br /> SECTION OF NEC SHALL BE STRICTLY COMPLIED WITH AND BE d RECEPTACLE DESIGNATIONS AS FOLLOWS: MLO MAIN LUG ONLY <br /> CONSISTENT THROUGHOUT ENTIRE SYSTEM. GFCI=GROUND FAULT INTERRUPTER WP=WEATHERPROOF P POLE <br /> 7. ALL CIRCUITS SHALL BE PROVIDED WITH AN INSULATED EQUIPMENT S=SWITCHED E=EMERGENCY POWER PART PARTIAL CIRCUIT <br /> GROUND CONDUCTOR SIZED IN ACCORDANCE WITH CEC. RACEWAY IG=ISOLATED GROUND AC=ABOVE COUNTER PC PHOTOCELL <br /> SHALL NOT BE USED AS EQUIPMENT GROUND. H=HORIZONTALLY MOUNTED PNLBD PANELBOARD <br /> 8. IN ADDITION TO MECHANICAL FASTENING TO CEILING TRACK, SUPPORT d HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED ON PLANS. RCPT RECEPTACLE <br /> LIGHT FIXTURES AT EACH CORNER INDEPENDENTLY OF SUSPENDED RTU ROOF TOP UNIT <br /> CEILING WITH 12 GAUGE WIRE. CONNECT TO STRUCTURAL SYSTEM OF FLOOR MOUNTED DUPLEX RECEPTACLE TS TIMESWITCH <br /> BUILDING. INSTALLATION SHALL MEET OR EXCEED SEISMIC TFX TRANSFORMER <br /> REQUIREMENTS OF LOCAL AND NATIONAL CODES. CEILING MOUNTED DUPLEX RECEPTACLE TYP TYPICAL CONSULTANT <br /> 9. ALL CONDUIT SHALL BE CONCEALED UNLESS OTHERWISE NOTED. ALL QUAD RECEPTACLE LINO UNLESS NOTED OTHERWISE <br /> EMPTY CONDUIT SHALL HAVE A PULL WIRE. V VOLT <br /> 10. ALL JUNCTION OR DEVICE BOXES SHALL HAVE A COVER. q) SPECIAL PURPOSE RECEPTACLE. REFER TO PLANS FOR VA VOLT/AMPERE <br /> 11. EACH PIECE OF ELECTRICAL GEAR, EQUIPMENT, ETC., SHALL BEAR A"UL" MORE INFORMATION. W WIRE <br /> LABEL. 6"ABOVE COUNTER DUPLEX RECEPTACLE - NEMA 5-20R UNLESS WP WEATHERPROOF <br /> 12. ALL EMERGENCY AND EXIT LIGHTS SHALL BE CONNECTED TO THE CIRCUIT NOTED OTHERWISE <br /> INDICATED IN THE PANEL SCHEDULES AHEAD OF SWITCHING MEANS ORJQ J JUNCTION BOX <br /> CONTACTORS. <br /> 13. PROVIDE ENGRAVED PHENOLIC LABELS ON ALL ELECTRICAL GEAR, CONNECTION POINT <br /> DISCONNECTS, ETC. V TELEPHONE OUTLET <br /> EL <br /> ��� <br /> 14. EC SHALL INSTALL HEAVY DUTY NEMA-1 DISCONNECTS AT ALL INTERIOR V TELEPHONE/DATA OUTLET <br /> LOCATIONS INDICATED AND HEAVY DUTY NEMA-3R DISCONNECTS AT ALL <br /> EXTERIOR LOCATIONS INDICATED ON THESE DRAWINGS. V DATA OUTLET <br /> 15. LIGHTING SWITCHES, RECEPTACLES AND/OR DATA OUTLETS SHALL NOT FLOOR MOUNTED DATA OUTLET <br /> BE MOUNTED BACK TO BACK IN ANY WALL. <br /> 16. ELECTRICAL DEVICE MOUNTING HEIGHTS (UNO): ELECTRICAL PANELBOARD- SURFACE AND RECESSED MOUNTED <br /> PANELBOARDS 6-6"AFF TO TOP PLYWOOD TELEPHONE TERMINAL BOARD (4'x8'x3/4" UNO) <br /> TOGGLE SWITCH 4'-0"AFF TO TOP OF BOX <br /> RECEPTACLES V-6"CENTERLINE <br /> WIRELESS ACCESS POINT <br /> VOICE/DATA OUTLETS 1'-6"CENTERLINE <br /> EMERGENCY LIGHT 12" BELOW FINISHED CEILING <br /> DISCONNECT SWITCH <br /> 17. PROVIDE TYPE-WRITTEN PANELBOARD SCHEDULES FOR ALL ELECTRICAL CI <br /> 60/3/NF = 60 AMP SWITCH, 3 POLE, NON-FUSED <br /> PANELBOARDS. <br /> 18. ALL 120 VOLT OUTDOOR RECEPTACLES TO HAVE"WET LOCATION - IN USE" 60/3/40= 60 AMP SWITCH, 3 POLE, 40 AMP FUSE <br /> COVERS. TS# TIME SWITCH <br /> C# CONTACTOR <br /> PC PHOTO CELL <br /> Lij <br /> LIGHT FIXTURE - REFER TO LIGHT FIXTURE SCHEDULE z W <br /> FFOR MORE INFORMATION <br /> Oa a - INDICATES SWITCHING SCHEME. CONNECT LIGHT FIXTURE TO O <br /> SWITCH <br /> .,a.,. U) <br /> EXIT SIGN -CEILING/WALL MOUNTED, ARROWS AS INDICATED - REFER J z <br /> TO Q <br /> LIGHT FIXTURE SCHEDULE FOR MORE INFORMATION Q U <br /> EMERGENCY BATTERY PACK LIGHT FIXTURE - REFER TO LIGHT <br /> FIXTURE z <br /> Lu SCHEDULE FOR MORE INFORMATION O <br /> LOW VOLTAGE WIRING z 0 <br /> O CEILING MOUNTED OCCUPANCY SENSOR- SENSOR SWITCH CM-9-R Q U <br /> C� O <br /> N <br /> \�A-1 CONDUIT RUNS ARE SHOWN ON POWER PLANS FOR CLARITY. O <br /> 06 CIRCUIT DESIGNATIONS AS FOLLOWS: <br /> A-1 SINGLE PHASE CIRCUIT. CONNECT TO PANELBOARD#1 WITH (1) O J <br /> HOT/SWITCH LEG, (1) NEUTRAL AND (1) GROUND.* j <br /> � S <br /> A-3,5 TWO PHASE CIRCUIT. CONNECT TO PANELBOARD A, #3,5 WITH <br /> (2) CONDUCTORS AND (1) EQUIPMENT GROUND. PROVIDE z <br /> NEUTRAL AS REQUIRED PER EQUIPMENT. <br /> A-7,9,11 THREE PHASE CIRCUIT. CONNECT TO PANELBOARD CIRCUIT# <br /> 7,9,11 WITH (3)CONDUCTORS AND (1) GROUND. PROVIDE <br /> NEUTRAL AS REQUIRED PER EQUIPMENT. <br /> REFERENCE PANELBOARD SCHEDULES FOR WIRE SIZES ALL CONDUIT <br /> SHALL HAVE EQUIPMENT GROUND WIRE. PROVIDE ISOLATED GROUND <br /> WIRE WHERE INDICATED. <br /> *3-WAY AND 4-WAY SWITCHING REQUIRES ADDITIONAL CONDUCTORS FOR <br /> PROPER OPERATION. PROVIDE AS REQUIRED FOR A COMPLETE WORKING <br /> LIGHTING CONTROL SYSTEM. PROVIDE UN-SWITCHED HOT TO ALL <br /> EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS. <br /> BLDG DEPT. 10. 11 . 19 <br /> REVISIONS <br /> 11/15/19 <br /> SEAL/SIGNATURE <br /> JOB NO. 1497.009 <br /> DRAWN RB <br /> CHECK AR <br /> ELECTRICAL NOTES, <br /> SYMBOLS & <br /> ABBREVIATIONS <br /> SHEET <br />