24 <br /> MC CABLE co <br /> a <br /> 0 ELECTRICAL NOTES: <br /> WIRE WAY w 1. ALL RECEPTACLES SERVED FROM PANEL"S" SHALL BE OF THE ISOLATED <br /> 3 POLE-100A p GROUND TYPE.ALL CIRCUITS SHALL CONTAIN A HOT, NEUTRAL, GROUND <br /> CONTACTOR (CEILING AND ISOLATED GROUND CONDUCTOR. <br /> 2. AMPACITY OF ALL CONDUCTOR SIZES SHOWN ON PLANS IS BASED ON 75°C i <br /> TO WIRE RATED TERMINATIONS AND CONDUCTOR INSULATION. CONTRACTOR SHALL <br /> WAY EMT CONDUIT FIELD VERIFY EQUIPMENT TEMPERATURE RATINGS OF ALL TERMINATIONS <br /> WEMS U U <br /> 0 LL L AND ADJUST CONDUCTOR SIZES PER CEC 110.14(C) <br /> Lu > U) > <br /> Lu CP-1 SPD U 3. ALL WIRING IS COPPER. REFER TO ELECTRICAL SPECIFICATIONS <br /> O w w CONDUIT PENETRATION CONDUIT AT CEILING PENETRATION FOR FURTHER INFORMATION. <br /> Of Q z SEALED WITH SILICONE FILLED WITH SEALANT 5865 Owens Drive <br /> 4. ALL WALL MOUNTED RECEPTACLES SHALL BE 18"A.F.F ON <br /> METER O O SEALANT CONDUIT AND WIRING TO PANEL CENTER. UNLESS NOTED OTHERWISE. Pleasanton, CA 94588 <br /> PANEL ~ U WIRE WAY CONDUIT AND WIRING TO FURNISHED BY OWNER, INSTALLED BY G.C. 5. FURNISH AND INSTALL CORD AND CAP FOR ALL EQUIPMENT 925-251-7200 <br /> MDP Q PNL PNL PNL PNL PNL PNL NEXT JUNCTION BOX ON COOLER/FREEZER BOX CEILING CONNECTED TO NEMA L-14R RECEPTACLE. <br /> O CT a A B S L C F SAME SYSTEM <br /> CABINET DBOX �, 6. G.C. TO COORDINATE POWER REQUIREMENTS FOR EXTERIOR SIGNAGE. <br /> CEILING MOUNTED WP JUNCTION BOX <br /> SIR WITH THREADED HUBS AND GASKETED 7. THE UNGROUNDED AND GROUNDED CONDUCTORS OF EACH MULTIWIRE <br /> r ID , COVERPLATE BRANCH CIRCUIT SHALL BE GROUPED BY WIRE TIES OR SIMILAR MEANS IN <br /> DD DD ID - � IR I TYPICAL COIL AT LEAST ONE LOCATION WITHIN THE PANELBOARD OR OTHER POINT OF <br /> �� ORIGINATION. REF 2011 CEC (210.4(D)) <br /> LIGHTING [=ff= PROVIDE CEILING MOUNTED MANUALWIREWAY WIRE WAY CONTACTOR WIRE WAY TWO-POLE SWITCH IN WEATHERPROOF 8. EACH MULTIWIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS <br /> ENCLOSURE. THAT WILL SIMULTANEOUSLY DISCONCECT ALL UNGROUNDED <br /> S�Li6� CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUITS ORIGINATES. <br /> _ __� 2 REF 2011 CEC (210.4) <br /> >_ a co (1) a 2i cn cn co W 0 0 m FLOOR 9. CONDUITS THAT ARE EXPOSED TO WIDELY DIFFERENT TEMPERATURES, <br /> � w 0 0 a Of wp I­_ I­_ z a Q Of 0- <br /> 2i _ _ w w U) v _j J C� O > w 2i LIQUID TIGHT FLEX CONDUIT TO SUCH AS COOLERS, FREEZERS OR SERVICE ENTRANCE CONDUCTORS, <br /> D a0 Of I� z z w w � 0 OJ a z 0- KNOCKOUT ON UNIT. FINAL SHALL BE SEALED TO PREVENT CIRCULATION OF AIR AND/OR MOISTURE. <br /> O I W LuLu W 0- P � O >- a Q Lu O CONCECTION TO COIL BY GC REF 2011 CEC (300.7 (A)) <br /> Z_ z w O CONSULTANT <br /> 10. CONDUIT AND WIRING IN AREAS WHERE EXPOSED SHALL BE ROUTED AT 90 <br /> LLI z O O 0 U O DEGREE ANGLES PERPENDICULAR OR PARALLEL TO JOISTS. COORDINATE <br /> D O <br /> ~ ~ ~ NOTE: DO NOT LOCATE WP JUNCTION BOX DIRECTLY IN FRONT OF DISCHARGE FAN, OFFSET TO SIDE. PAINTING OF CONDUIT WITH ARCHITECTURAL FINISHES. <br /> 3 PANELBOARD ELEVATION 2 EVAPORATOR COIL WIRING <br /> N.T.S. N.T.S. <br /> Ego <br /> KEYNOTES - POWER E L <br /> ��� <br /> EXHAUST FAN. SWITCH FAN WITH RESTROOM LIGHTS,TYP. <br /> DEVICES SHALL BE NEMA 5-20 UNLESS NOTED OTHERWISE.TYP OF <br /> 120V-20A CIRCUITS. <br /> EXTERIOR SIGNAGE J-BOX. COORDINATE FINAL LOCATION WITH <br /> SIGNAGE CONTRACTOR AND CONSTRUCTION MANAGER. RUN <br /> EXTERIOR BUILDING SIGNS THROUGH PHOTOCELL DRIVEN <br /> CT CABINET MAIN DIST. CONTACTOR. PROVIDE PAD-LOCKABLE BREAKER FOR MAINTENANCE. <br /> UTILITY CO. PANEL 'MDP' ENERGY MANAGEMENT ENCLOSURE PROVIDED BY OTHERS, PROVIDE <br /> METER 120V DEDICATED CIRCUIT ONLY. <br /> _ ❑ RECEPTACLE FOR ATM SIGN.VERIFY LOCATION WITH CONSTRUCTION <br /> MANAGER PRIOR TO COMMENCEMENT OF WORK. <br /> 17 [6] WINDOW RECEPTACLES. MOUNT FLUSH IN CEILING, MOUNT <br /> ABOVE WINDOW HEADER IN OPEN CEILING AREA, PER CEC <br /> ,45 BUMS- 14 - J — — — TELEPHONE BOARD:4'X4'X3/4" PLYWOOD WITH (1)#6 CU. <br /> C-12,14 -1 B-6,8 -9,11 - 19, 1 B-42 C-1° 1 PANELBOARD 'F' GROUND FOR FUTURE USE MOUNTED ABOVE 4'X4'X3/4" <br /> L6-30 4 ' L6-30 14-50 L14-5 6-3 +42" PANELBOARD 'C' PLYWOOD WITH (1)#6 CU. GROUND PER TELE. CO. <br /> II I o REQUIREMENTS. MOUNT RECEPTACLE ADJACENT TO OR <br /> + +42 42 I PAN OARD 'L' ABOVE TELEPHONE BOARD, DO NOT MOUNT BELOW. <br /> _ _ 0 _ B-2 ELBOARD 'S' <br /> 11 GFCI PAN BOARD 'B' 8 PROVIDE PAD-LOCKABLE BREAKER FOR MAINTENANCE PER N.E.C. <br /> B-33 B-29 25 +24" �-- _ PANELBOARD 'A' � 422.31(B). COORDINATE EXACT LOCATION OF ELECTRICAL OUTLET WITH w <br /> 2 +42" B-23 B-17 B-2 w <br /> — B-35 B-53 CONSTRUCTION MANAGER PRIOR TO ROUGH-IN. <br /> +42" B-31 B-25,27 +42 GFCI GFCI ❑ REFER TO EVAPORATOR COIL WIRING DETAIL, RE: 2/E1.0,TYP. 0 I� <br /> I 25 B-37 +42" L6-30 42 8 �F-1 B-3 9 <br /> L5-20 +42" J B-4 F-3 10 VEEDER ROOT: COORDINATE INSTALLATION WITH FUELING PLANS. U) <br /> B-53 B-17 +84" B-34 J INSTALL IN ACCESSIBLE LOCATION. MOUNT AT 48"A.F.F. TO BOTTOM. z <br /> GFCI GFCI 11 RECEPTACLE FOR MOTION SENSOR FAUCET. REFER TO J _ Q <br /> I O O 5 ARCHITECTURAL SHEETS FOR EXACT ROUGH-IN LOCATIONS, TYP. Q U <br /> 4—S-10 12 RECEPTACLE FOR WATER FILTRATION BOOSTER PUMP, E.C.TO INSTALL <br /> _ WATER-RESISTANT, "WHILE-IN-USE"COVER. z <br /> o 2 E.C. TO PROVIDE WIRING FOR COOLER AND/OR FREEZER DOOR <br /> 15 _ _ w <br /> 9 I I B-36,38 � � � ° 15 2 19 � 13 SUPPL EDJUDNCTOION BOX ES AND CONCECT TO MANUFACTURER � O <br /> �C-41 C-31 I ( ) z <br /> C-35,37 �- — L6-20 - - 6-10,12 +93 E.C.TO INSTALL WEATHERPROOF J-BOX FOR RAYCHEM HEAT TRACE <br /> 6-20 14 WHICH SUPPLIES FREEZE PROTECTION FOR FREEZER CONDENSATE U <br /> C_3 C-15,17 C_39 J11 111 A 1)111 111 1 <br /> I LINES. FURNISH HEATTRACE AND PROVIDE GFI-EPD CIRCUIT BREAKER � j O <br /> ° 0 6-30 B_2 I AND INSTALL PER MANUFACTURER'S REQUIREMENTS. REF. (�� <br /> 15 C8,30 <br /> 15 B-18,20 r + CI `� z U) <br /> ELECTRICAL SPECIFICATIONS. <br /> B-24,267BB-14,16 6-20 C 9 +72 ROUTE CIRCUITRY FOR EQUIPMENT UNDER SLAB, RE: 1/E1.26-20 6 6-20 \ \ G I GFCI GFCI 15 O <br /> _ 15 / C- 1, +24" 11 C� I 16 SERVICE RECEPTACLE,WEATHERPROOF GFCI. O J <br /> CLG S-21 C 3 GFCI 17 REFER TO DETAIL#5 ON GAS PLANS SHEET G10 FOR PANEL'F' CONDUIT <br /> I _ MTD 5-15R G I 1 C-6 ROUTING. <br /> — ® +84° ❑ ❑ 18 EMERGENCY GAS SHUT-OFF @ 48"A.F.F. Z <br /> C-25,27 - TRANSMITTER RECEPTACLE, G.C. TO PROVIDE. MR. CHIME ENTRANCE <br /> I 6-30 — — 1 19 ALERT TRANSMITTER(DA4TAC). CONTACT MR. CHIME AT 877-672-4463. <br /> L-27 <br /> +42' d-4 _ — _j RECEIVER RECEPTACLE, G.C. TO PROVIDE. MR. CHIME RECEIVER(DARD). <br /> _ 20 <br /> +24" <br /> RECESSED <br /> CLG S-19 l INSTALL WEATHERPROOF SPEAKER, G.C.TO PROVIDE MR. CHIME <br /> 2 I I CLOCK OUTLET MTD 5D-15R _ 21 <br /> 10 SPEAKER(SPK).MOUNT ON WALL IN WALK IN COOLER AND CONCECT TO <br /> 9 P S-27 ❑ NEAREST RECEIVER OUTSIDE OF COOLER. <br /> C-35,37 15 GFCI \ 20 + ° ® 22 ISOLATED GROUND (IG)20 AMP CIRCUIT FOR ATM, FLUSH MOUNT <br /> 36" <br /> I +42" C-31� 2 El FACE PLATE WITH ORANGE RECEPTACLE. <br /> — B-40 C-11 +93�� 1 +�4" 23 E.C.TO MAINTAIN <br /> MACHINE. <br /> 2 SPACING BETWEEN RECEPTACLES FOR STAND UP <br /> — GFCI <br /> 4 1.6 24 WIREWAY TO COMPLY WITH WIREWAY SIZE, NUMBER OF CONTACTORS, <br /> AND REDUCTION FACTOR PER NEC 376.22 (A)&(B). <br /> — E1.6 25 RECEPTACLE O SPEAKER BE FLUSH MOUNTED <br /> SPEAKER. VERIFYEXACT HEIGHT DIRECTLY IBLDG DEPT. 10.11 .19 <br /> TAND LOCATION WITH ARCHITECTURAL <br /> O ° DRAWINGS. INSTALLER TO HIDE POWER CABLE BEHIND THE SPEAKER <br /> USING CABLE TIES. <br /> — REVISIONS <br /> 3 I 13 I ❑ m U) <br /> L-15 CLG S-19 <br /> -CIRC I��' 2 PR#2 01.06.20 <br /> C-33(�J MTD 5-15R � RE pump <br /> A <br /> 9 S-3 (TYP.) C- 3 <br /> -35,37 25 S-5 - 11 <br /> B-53 -31 5 S-7 15 S-13 2 S-25 M o A-13,15,17 <br /> 20 93" 22 L-23 6 S-9 S-15 NEMA 1 <br /> 21 23 +-25 L-19 S-11 6 E1.6 7 — — 60/3/NF <br /> +96" <br /> SPKFS-] S_ 3 L-21 +93" <br /> 3193.. S _j9AI1 \4r L moi j <br /> ® ° L- 9 <br /> 19 — _L_ <br /> D�O HBL-4792 B-48 <br /> WP/GFCI <br /> ® 3 NOTE: MONEY ORDER AND NEMA 3R D O 12 <br /> 16 L_7 LOTTO CORDS TO BE RAN 18 16 3MA 3R L-29 <br /> A-21 IN SAME GROMMET. <br /> A- 3 A-21 2 WP/GFCI <br /> WP/GFCI — — — — — — — — — — — — — — — — — J WP/GFCI +42" <br /> 18 NOTE: THERE SHALL BE NO <br /> A-23 RECEPTACLES INSTALLED <br /> UNDER THE LOTTO SCRATCH <br /> UP AREA. <br /> D 0 0 0 0 0 0 C O 0 0 0 O B 0 A <br /> 11/15/19 <br /> SEAL/SIGNATURE <br /> JOB NO. 1497.009 <br /> DRAWN RB <br /> CHECK AR <br /> ELECTRICAL POWER <br /> PLAN <br /> 1 ELECTRICAL POWER PLAN SHEET <br /> SCALE: 1/4" = V-0" <br /> 1 2 4 8 <br /> SCALE: 1/4"= 1'-0" PROJECT <br /> NORTH <br />