Laserfiche WebLink
River Islands Development at Lathrop November 2020 <br /> Final Phase 2 Sewer Technical Report Rev 1 #6520 <br /> 7. River Islands Sewer Collection System Model — Phase I Results <br /> 7.1 Sewer Collection Area Al <br /> 7.1.1 Sewer Collection Area Al —Land Uses,Average Dry Weather Flows, and Peak Wet Weather Flows <br /> Sewer Collection Area Al is located in the western portion of Phase I and is comprised of development <br /> Stages 2A and 2B of Phase 1. Area Al encompasses approximately 785 acres composed of low and <br /> medium density residential units as well as parks, a K-8 school, and a high school. The calculated ADWF <br /> from collection area Al is 603,302 GPD as shown in Table 7-1. At full buildout and under normal operating <br /> conditions, the proposed LS-C2 will discharge sewage into Al's collection system along River Islands <br /> Parkway. ADWF from collection areas C1+C2 and Al produces a PWWF of 2,306,068 GPD to Al lift <br /> station (previously referred to as Stage 2A lift station). <br /> Table 7-1: Sewer Collection Area Al — Land Uses, ADWF, and PWWF <br /> Land Use <br /> Area Al Sewer Flow Average Dry <br /> Total No of DU Factor Weather Flow <br /> Land Use or Acres GPD/du or ac GPD <br /> Low Density Residential (per DU) 1,998 200 399,600 <br /> Medium Density Residential (per DU) 723 180 130,140 <br /> High Density Residential (per DU) 312 170 53,040 <br /> Commercial (per acre) 0.0 590 0 <br /> Industrial (per acre) 0.0 355 0 <br /> Parks (per acre) 88.0 55 4,842 <br /> Schools/ Institutional per acre 64.0 1 245 15,680 <br /> Total Area Al Average Dry Weather Flow 603,302 <br /> From Collection Area C1 + C2 Average Dry Weather Flow 509,409 <br /> Total Average Dry Weather Flow 1,112,710 <br /> Peaking Factor 2.07 <br /> Peak Wet Weather Flow' 2,306,068 <br /> Notes: <br /> 1. PWWF shown is based on the ADWF from areas C1+C2 and Al conveyed to the LS-A1 <br /> 7.1.2 Sewer Collection Area Al — Pipe Capacity Under PWWF <br /> Figure 7-1 shows the PWWFs of all the pipes within Area Al and the corresponding pipe capacities in <br /> accordance with the City's Standards. None of the pipes exceeded the maximum capacity(Depth/diameter <br /> ratio) requirement described in Section 4.1.1. <br /> 7.1.3 Sewer Collection Area Al — Pipe Velocities Under PWWF <br /> Figure 7-2 shows the velocity of each pipe within Area Al under PWWFs. None of the pipes exceed the <br /> maximum allowable velocity list in the City Standards. <br /> As shown in Figure 7-2, 6 segments of pipe are estimated to have a velocity less than 2 feet per second <br /> with the line being at least half full under PWWF conditions. All 6 of these pipes are located along or in <br /> close proximity to the eastern trunk line. Phase I infrastructure was design in accordance with the City's <br /> 2014 Standards which utilized higher sewer generation rates than the 2019 City Standards, reflecting <br /> historical trends seen in the City. The few segments in which the model determined low sewer velocities <br /> may occur, can be attributed to the reduction in sewer generation rates as required by the 2019 City <br /> 26 <br />