Laserfiche WebLink
River Islands Development at Lathrop January 2021 <br /> Final River Islands Potable Water Technical Report—Rev 3 #6520 <br /> Table 2-4: River Islands— Phase I and II Maximum Day Demands (Peaking Factor= 1.7) <br /> MDD Demand MDD <br /> Phase I &II ADD Demand Factor MDD (GPM) <br /> (Total) Factor (GPD per DU or (GPD) W/5% <br /> No.of Units (GPD per DU or Acre) Acre) W/5%Loss Loss <br /> Land Use or Acreage W/5%Loss Factor W/5%Loss Factor Factor Factor <br /> Low Density Residential (per DU) 7,191 330.8 562.3 4,043,320 2,808 <br /> Medium Density Residential (per DU) 3,636 246.8 419.5 1,525,211 1,059 <br /> High Density Residential (per DU) 4,183 141.8 241.0 1,007,998 700 <br /> Commercial (per acre) 287.2 903.0 1,535.1 440,858 306 <br /> Industrial (per acre) 0.0 1,260.0 2,142.0 0 0 <br /> Parks(per acre) 65.1 2,572.0 4,373.3 284,830 198 <br /> Schools/Institutional (per acre 61.8 1,575.0 2,677.5 165,470 115 <br /> Subtotal 7,467,686 5,186 <br /> Table 2-5: River Islands— Phase I and II Peak Hour Demands (Peaking Factor= 3.4) <br /> PHD Demand PHD <br /> Phase I &II ADD Demand Factor PHD (GPM) <br /> (Total) Factor (GPD per DU or (GPD) W/5% <br /> No. of Units (GPD per DU or Acre) Acre) W/5%Loss Loss <br /> Land Use or Acreage W/5%Loss Factor W/5%Loss Factor Factor Factor <br /> Low Density Residential (per DU) 7,191 330.8 1,124.6 8,086,639 5,616 <br /> Medium Density Residential (per DU) 3,636 246.8 839.0 3,050,422 2,118 <br /> High Density Residential (per DU) 4,183 141.8 482.0 2,015,997 1,400 <br /> Commercial (per acre) 287.2 903.0 3,070.2 881,715 612 <br /> Industrial (per acre) 0.0 1,260.0 4,284.0 0 0 <br /> Parks(per acre) 65.1 2,572.0 8,746.5 569,660 396 <br /> Schools/Institutional (per acre 61.8 1,575.0 5,355.0 330,939 230 <br /> Subtotal 14,935,372 105372 <br /> 2.4 Fire Flow Requirements <br /> Fire flows are required to meet the Lathrop-Manteca Fire Protection District(LMFPD) requirements and as <br /> outlined in Table 4-2 in the City's Standards (see Appendix D &Table 2-6). The required fire flows must <br /> be provided in conjunction with MDDs for a minimum 2-hour duration, while maintaining a system-wide <br /> residual pressure of 20 psi (including at the flowing hydrant). <br /> Table 2-6: Fire Flow Requirements <br /> Fire Flow Required <br /> Land Use (GPM) <br /> Low Density Residential 1,250 <br /> Medium Density Residential 1,250 <br /> High Density Residential 2,000 <br /> Commercial 3,000 <br /> Industrial 4,000 <br /> 10 <br />