<br /> Table 10: SSJID SCWSP Supply Available Under Normal and Dry Year Conditions
<br /> Estimated Supply and Demand AFY
<br /> 2020 2025 2030 2035 20401
<br /> Normal Year
<br /> Total SCWSP Projected 30,969 31,203 31,442 31,684 31,684
<br /> Supply
<br /> Total SCWSP Projected 31,552 31,552 31,552 31,552 31,552
<br /> Demand
<br /> Surplus or Deficit -583 -349 -110 132 132
<br /> Percent Shortfall 1.8% 1.1% 0.3% -- --
<br /> Single-Dry Year
<br /> Total SCWSP Projected 23,226 23,403 23,581 23,763 23,763
<br /> Supply
<br /> Total SCWSP Projected 31,552 31,552 31,552 31,552 31,552
<br /> Demand
<br /> Surplus or Deficit -8,326 -8,149 -7,971 -7,789 -7,789
<br /> Percent Shortfall 26% 26% 25% 25% 25%
<br /> Multiple-Dry Year-First Year
<br /> Total SCWSP Projected 26,839 27,043 27,250 27,459 27,459
<br /> Supply
<br /> Total SCWSP Projected 31,552 31,552 31,552 31,552 31,552
<br /> Demand
<br /> Surplus or Deficit -4,713 -4,509 -4,302 -4,093 -4,093
<br /> Percent Shortfall 15% 14% 14% 13% 13%
<br /> Multiple-Dry Year-Second Year
<br /> Total SCWSP Projected 27,614 27,823 28,036 28,251 28,251
<br /> Supply
<br /> Total SCWSP Projected 31,552 31,552 31,552 31,552 31,552
<br /> Demand
<br /> Surplus or Deficit -3,938 -3,729 -3,516 -3,301 -3,301
<br /> Percent Shortfall 12% 12% 11% 10% 10%
<br /> Multiple-Dry Year-Third Year
<br /> Total SCWSP Projected 26,086 26,284 26,484 26,688 26,688
<br /> Supply
<br /> Total SCWSP Projected 31,552 31,552 31,552 31,552 31,552
<br /> Demand
<br /> Surplus or Deficit -5,466 -5,268 -5,068 -4,864 -4,864
<br /> Percent Shortfall 17% 17% 16% 15% 15%
<br /> Source:City of Lathrop 2019 WSMP,Table 5-6(EKI,2019)
<br /> Note:
<br /> 1. It is assumed that 2040 projected supplies and demand are consistent with 2035 estimates. :In summer 2018,the City completed a
<br /> Phase 2 Expansion of the facility to a total capacity of 2.5 MGD ADWF to accommodate future growth in the Mossdale,Central
<br /> Lathrop,and River Islands development areas.The Lathrop CTF is permitted for a maximum capacity of up to 6.0 MGD with
<br /> additional expansions.
<br /> Califia(0011533.00) 26 Woodard&Curran, Inc.
<br /> River Islands Phase 2 Development Water Supply Assessment September 2020