My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Operation Alarms <br /> seven days'time period. When a test first fails, a warning is posted and a warning event is logged. If this condition <br /> persists for seven more consecutive days, an alarm is posted, a failure alarm event is logged and the site is <br /> shutdown. If the condition continues, additional failure events are logged and the site will continue to be shutdown <br /> each day. <br /> ISD ALARM SUMMARY <br /> Table 3 summarizes the ISD Alarms-Alarms with footnote 2 will result in a site shutdown. <br /> Table 3.SD Alarm Summary <br /> ISD Monitoring Light Suggested <br /> Displayed Message Category Indicator Cause Troubleshooting' <br /> ISD VAPOR LEAKAGE WARN Containment Yellow Vapor Leakage Detection -Exhibit 7 Nozzle Bag Test <br /> test warning -Exhibit 9/10 Operability Test <br /> •T.P.201.1 E-PW Test <br /> ISD VAPOR LEAKAGE FAIL2 Containment Red Vapor Leakage Detection .Exhibit 4 Clean Air Separa- <br /> test-8th consecutive failure for Test <br /> •TP-201.3 <br /> ISD GROSS PRESSURE WARN Containment Yellow Gross Over Pressure test -Are ball valves for the clean <br /> warning air separator in the correct <br /> position? <br /> ISD GROSS PRESSURE FAIL2 Containment Red Gross Over Pressure test- -Is the ball valve near the <br /> 8th consecutive failure pressure sensor in the cor- <br /> rect position? <br /> ISD DEGRD PRESSURE WARN Containment Yellow Degradation Over-Pressure -Exhibit 7 Bag Test <br /> test warning •T.P.201.1 E-PVV Test <br /> •T.P.201.3 <br /> ISD DEGRD PRESSURE FAIL2 Containment Red Degradation Over-Pressure -Look for problems using one <br /> test-30th consecutive fail- or more of the following VR- <br /> ure 202 procedures/tests:Dis- <br /> penser Integrity Test B-3(i.e. <br /> 'Pumbing Tightness'test), <br /> Exhibit 4,Exhibit 5,Exhibit 9 <br /> (pressure sensor only)or <br /> Flow Rate Verification per <br /> section 1.2.3. <br /> Hnn:GROSS COLLECT WARN Collection Yellow 1-Day Gross A/L Test warn- <br /> ing <br /> Hnn:GROSS COLLECT FAIL2 Collection Red 1-Day Gross A/L Test failure -Visually inspect hanging <br /> -2nd consecutive failure hardware at the affected fuel- <br /> ing point <br /> Hnn:DEGRD COLLECT WARN Collection Yellow 7-Day Degradation A/L Test -Exhibit 7 Nozzle Bag Test <br /> warning -VR-202 Exhibit 5 <br /> Hnn:DEGRD COLLECT FAIL2 Collection Red 7-Day Degradation A/L Test <br /> -consecutive failure <br /> ISD SENSOR OUT WARN Self-Test Yellow ISD Sensor Out Self-Test <br /> warning Confirm ISD sensor&mod- <br /> ule installation/communica- <br /> ISD SENSOR OUT FAIL2 Self-Test Red ISD Sensor Out Self-Test- tion per section 2. <br /> 8th consecutive failure <br /> ISD SETUP WARN Self-Test Yellow System Setup Self-Test <br /> warning Confirm EVR/ISD program- <br /> ISD SETUP FAIL2 Self-Test Red System Setup Self-Test fail- ing per section 3. <br /> ure-8th consecutive failure <br /> See ISD Troubleshooting Manual P/N 577013-819 for a complete list of suggestions. <br /> 2 ISD Shutdown Alarms-see"Site Reenable"on page 26. <br /> IB-28 <br /> GARB Approved IBM 10 -Veeder Root ISO Install,Setup,9 Operation Manual-Executive Order VR-262 <br />
The URL can be used to link to this page
Your browser does not support the video tag.