Operation Reports <br /> Table 4 summarizes additional alarms that may be posted by ISD related equipment.These alarms are not critical <br /> to vapor recovery functionality, but could indicate erroneous setup or equipment malfunction. NOTE: Additional <br /> TLS console alarms listed in the TLS-3XX Operator's manual may be posted and may lead to an ISD shutdown <br /> alarm if persistent (see ISD Troubleshooting Manual for details). <br /> Table 4. Other Alarms <br /> Light <br /> Displayed Message Indicator Set Condition Clear Condition <br /> MISSING RELAY SETUP Red One or more required shutdown Setup required shutdown alarms. <br /> alarms have not been assigned to a <br /> relay. <br /> MISSING TANK SETUP Red There are no vapor recovery(gaso- Complete gasoline tank setup. <br /> line)tanks defined or a gasoline <br /> pump has not been assigned to a <br /> control (shut down) device in at <br /> least one tank. <br /> MISSING HOSE SETUP Red There are no product meters Assign at least 1 product meter to a <br /> assigned to a hose. hose. <br /> hnn:VPRFLOW MTR SETUP Red Incoming transaction from a hose Configure Vapor Flow Meter(Smart <br /> with an unavailable Vapor Flow Sensor)and enable it in ISD. <br /> Meter. <br /> MISSING VAPOR PRES SEN Red There is no Vapor Pressure Sensor Complete Vapor Pressure Sensor <br /> setup or detected. setup. <br /> MISSING VAPOR FLOW MTR Red There is no Vapor Flow Meter setup Complete Vapor Flow Meter setup. <br /> or detected. <br /> fnn:CHK VAPOR FLOW MTR Red Failure of volume measure test- Volume measure test passes or vapor <br /> possible problem vapor flow meter. flow meter deconfigured,or test <br /> cleared. <br /> Table 5.Wireless Related Sensor Alarms <br /> Light <br /> Fault Message Device Indicator Cause Suggested Troubleshooting <br /> BATTERY WARNING Vapor Flow Yellow Device transmitter reports battery Remove and replace battery. <br /> Meter, Pres- status as'Replace'for 24 hours <br /> sure Sensor <br /> Reports <br /> There are two main reports (CP-201 required) that are stored by the ISD system: the Monthly Status Report, <br /> stored for 12-months, and the Daily Status Report, stored for 365 days.A third report discussed in this section is <br /> the ISD Status Report. You can print out ISD reports from the TLS console front panel as shown in Figure 21. <br /> • The monthly report includes: <br /> -The Warning Log <br /> The Failure Log <br /> 10-29 <br /> CARO Approved IOM 10 -Veeder Root ISD Install,Setup,8 Operation Manual-Executive Order VR-202 <br />