COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pressure Sensor Installation Under Dispenser Installation Steps <br /> vapor return line. NOTE: In ISD installations,the pressure port used must be below the vapor flow <br /> meter outlet. <br /> 4. Install one of the 68CA-4-4 male connectors (item 2 in Table 1) from the kit into the tapped hole. <br /> 5. Install Pressure Sensor (item 1 in Table 1) vertically to the dispenser frame or piping using the 2-inch conduit <br /> clamp, rubber shim, and necessary bolts, nuts, and washers from the included Universal Sensor Mounting kit. <br /> Wrap the rubber shim (item 10 in Table 1) around the sensor before inserting it into the clamp. Also make <br /> sure the sensor cable outlet is facing up and the pressure sensing port tube in the base of the sensor is <br /> facing down. <br /> 6. Attach one end of the 62CA-4 union (item 3 in Table 1) to the pressure sensing port in the base of the <br /> Pressure Sensor. <br /> 7. Install the remaining 68CA-4-4 male connectors (item 2 in Table 1) from the kit into each of the three ports in <br /> the 3-way calibration valve (item 13 in Table 1). <br /> 8. Measure,fabricate, and install a 1/4" OD copper tube (item 12 in Table 1) that runs between the 62CA-4 <br /> union in the base of the sensor and the center port of the 3-way calibration valve. <br /> 9. Measure,fabricate, and install a 1/4" OD copper tube that runs between the 1/4"tube end of the male <br /> connector fitting installed beneath the shear valve mechanism and the right port on the 3-way valve, being <br /> careful not to create any potential liquid traps (Note 3-way valve orientation in Figure 6). <br /> 10. Screw the 59CA-4 plug, item 4, from the kit onto the left port's male connector. Make sure the valve's handle <br /> is set to connect the sensor to the vapor return line and not to the capped (ambient) port. <br /> Important!All plumbing's pitch to drain should be 1/4" vertical per 12" horizontal to eliminate liquid traps. <br /> 11. Route the cable from Pressure Sensor to the Pressure Sensor junction box in the dispenser. Observing <br /> polarity, connect the sensor wiring to the field wiring from console and cap with wire nuts (see Figure 7) - OR <br /> -terminate the wiring in the TLS RF transmitter (W2). In wireless installations, the wiring is not sealed and <br /> does not run back to the TLS console and Steps 12, 13 and 14 ARE NOT REQUIRED. <br /> 12. Seal wire nuts in epoxy sealant following the instructions in Figure 8. <br /> 13. Push the epoxy sealed bag into the junction box. Replace and tighten the junction box cover. <br /> 14. Terminate field wiring into TLS Console and connect to Smart Sensor Module (TLS-3XX- Figure 9). Note: <br /> observe polarity! The cable length between the console and sensor must not exceed the distance stated in <br /> the TLS-3XX Site Prep manual (P/N 576013-879). <br /> Note: Intrinsically safe devices must be installed in accordance with Article 504 of the National Electrical <br /> Code, ANSI/NFPA 70, for installation in the United States, or Section 18 of the Canadian Electrical Code for <br /> installations in Canada. <br /> This intrinsically safe Pressure Sensor P/N 331946-001, has only been evaluated for connection to a UL list- <br /> ed TLS-3XX Liquid Level Gauge/ Leak Detector. <br /> Conductors of different intrinsically safe circuits run in the same cable/conduit must have at least 0.01 inch <br /> (0.25 mm) of insulation. <br /> 15. After the Pressure Sensor is installed, pressurize the tank ullage space and vapor piping to at least 2 inches <br /> WC and test for leaks using leak detection solution. <br /> 16. Replace lower dispenser sheet metal doors onto dispensers. <br /> 10-6 <br /> CARB Approved IOM 10-Veeder Root Pressure Sensor-Executive Order VR-202 <br />