My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pressure Sensor Installation Vapor Vent Stack Installation Step <br /> 27. Terminate field wiring into TLS Console and connect to Smart Sensor Module (TLS console - Figure 9). Note: <br /> observe polarity! The cable length between the console and sensor must not exceed the distance stated in <br /> the TLS-3XX Site Prep manual (P/N 576013-879). <br /> Note: Intrinsically safe devices must be installed in accordance with Article 504 of the National Electrical <br /> Code, ANSI/N FPA 70, for installation in the United States, or Section 18 of the Canadian Electrical Code for <br /> installations in Canada. <br /> This intrinsically safe Pressure Sensor (P/N 331946-001), has only been evaluated for connection to a UL <br /> listed TLS-3XX Liquid Level Gauge/ Leak Detector. <br /> Conductors of different intrinsically safe circuits run in the same cable/conduit must have at least 0.01 inch <br /> (0.25 mm) of insulation. <br /> 28. After the Pressure Sensor is installed, pressurize the tank ullage space and vapor piping to at least 2 inches <br /> WC and test for leaks using leak detection solution. <br /> 29. Close the enclosure door and secure by threading the tamper-resistant screws into the enclosure body using <br /> a Torx bit for tamper-resistant screws. <br /> 30. Affix the eVRgreen label (item 30 in Table 2) to the enclosure door as desired. <br /> 10-17 <br /> CARB Approved IOM 10-Veeder Root Pressure Sensor-Executive Order VR-202 <br />
The URL can be used to link to this page
Your browser does not support the video tag.