My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Introduction <br /> The purpose of this manual is to guide installers,operators, and store owners with setting up their INCON Vapor Recovery <br /> Monitoring (VRM)system.The VRM system has been tested and approved by the California Air Resource Board as an <br /> In-Station Diagnostics(ISD)system per CP-201.This manual introduces the user interface then proceeds to setup and <br /> lastly, maintaining your VRM system. <br /> For installation of the TS-550,TS-5000,TS-EMS and its components please refer to the TS-5xxx Series Installation Guide <br /> (p/n 000-2150). <br /> Certified Contractor Requirements <br /> Please read this entire manual carefully. Failure to follow the instructions in this manual may result in faulty operation, <br /> equipment damage, injury or death. <br /> Contractor Certification Levels <br /> •LEVEL I-Automatic Tank Gauge Installer Certification Training <br /> *LEVEL II-Automatic Tank Monitor Start-Up and Service/Warranty Certification Training <br /> ,LEVEL III-LLD Installer/Service/Warranty Certification Training <br /> •LEVEL IV-TS-STS Operation/Repair Test <br /> •LEVEL V-Vapor Recovery Monitoring Installation/Operation <br /> Certified Programmer/Service Person: Only an INCON certified VRM Technician or service person is allowed to make <br /> setup changes, clear alarms, and access areas internal to the Console.A certified contractor needs to have completed <br /> training levels I, II,and V. <br /> Station Owner/Operator: The station owner or operator of the console is only allowed to print reports and re-enable <br /> dispensers. Making setup changes, clearing alarms, and accessing areas internal to the console is strictly prohibited. <br /> Definitions and Acronyms <br /> A/L—Air over Liquid ratio,this ratio is calculated at the end of the day for each fueling point. <br /> ATG—Automatic Tank Gauge <br /> CARB—California Air Resources Board <br /> DTU -Data Transfer Unit. Device used to transmit VFM and VPS data over existing power lines <br /> EVR—Enhanced Vapor Recovery <br /> GDF—Gasoline Dispensing Facility <br /> ISD—In-Station Diagnostics.This refers to the whole system as defined in CP-201. <br /> ISP—Internet Service Provider <br /> LLD—Line Leak Detector <br /> Modules—These are the different plug-in cards within the T5 series console enclosure.They are the inputs and outputs <br /> for all the field wiring. <br /> Console—The console is the physical box installed on the wall.The system console holds the entire electronic slide in <br /> modules and runs the general operating system.The VRM application is available in the TS-550/EMS/5000 models of the <br /> console. <br /> PLC-Power Line Communication.This refers to the technology of transferring digital data over AC power lines <br /> TS-VFM—Vapor Flow Meter <br /> TS-VPS—Vapor Pressure Sensor <br /> TSA—Tank Sentinel Anyware is the web-based interface to the console. <br /> VRM—Vapor Recovery Monitoring is the application that runs on the console and performs In-Station Diagnostics. <br /> Related Documents <br /> 000-2144, TS-VFM Installation Guide <br /> 000-2143, TS-VPS Installation Guide <br /> 000-2150, TS-5xxx Installation Guide for TS-5, TS-550, TS-5000, and TS-EMS <br /> 000-2142, TS-5xxx Programmer's Guide for TS-5, TS-550, TS-500, and TS-EMS <br /> 000-2151, TS-5xxx Operator's Guide <br /> CP-201, Certification Procedure for Vapor Recovery Systems at Gasoline Dispensing Facilities <br /> TP-201.3, Determination of a 2"Static Pressure Performance of Vapor Recovery Systems of Dispensing Facilities <br /> TP-201.5,Air to Liquid Volume Ratio <br /> II-5 <br /> CANB Approved IN 11-INCON Vapor Recovery Monitoring(VRM)-Executive Order VR-202 <br />
The URL can be used to link to this page
Your browser does not support the video tag.