Vapor Pressure Containment Warnings and Failures <br /> A Weekly or Monthly Ullage Pressure warning or failure occurs when the vapor pressure exceeds the operating threshold. <br /> The VRM system makes both a weekly and monthly assessment on the amount of time the vapor containment pressure <br /> exceeds a threshold over a specific period of time. If the containment pressure rises above the overpressure limits for <br /> either the weekly or monthly thresholds, then the VRM will issue a warning.A second consecutive period of exceeding the <br /> overpressure threshold will result in a failure alarm and a shutdown of all dispensers. <br /> A Weekly Ullage Pressure Leak Test warning or failure is an indication that the containment space(vapor space) is leaking <br /> vapors beyond the allowable limit.This assessment is performed on a weekly basis. If a vapor containment is leaking, the <br /> VRM will issue a warning at the end of the first week and if it is not fixed by the end of the second week then all dispenser will <br /> become disabled. <br /> See Appendix A for the Alarm Code description and possible solution, or the Vapor Recovery Monitoring Troubleshooting <br /> and Diagnostics Guide available on the Franklin Fueling Systems Web site: www.franklinfueling.com. <br /> Re-enabling Dispenser(s) <br /> Dispensers can be re-enabled by the following method. Note that this procedure does not clear any warnings or failures, it <br /> only re-enables dispensing. <br /> The Failed fueling point requires immediate attention and should be bagged so it is not used until <br /> Warning® the problem has been fixed by a certified Service Technician. Continuous use of a failed Fueling <br /> Point will result in another shutdown. <br /> WarningA Refer to local districts before putting a shutdown dispenser back into operation. <br /> From the LCD: <br /> 1. Go to the VRM»Dispensers menu (see Figure 5a &5b and Figure 6a & 6b). <br /> 2. Press the dispenser showing "Shutdown". <br /> 3. Press "Yes" on the confirmation box. <br /> From the Web Browser: <br /> 1. Go to the VRM»Status page. <br /> 2. Press the red "Shutdown"for each dispenser showing shutdown. <br /> 3. Press "Yes"to enable the dispenser or all dispensers. <br /> Franklin Fueling 6yatemts VRM <br /> Home System FMS 'VFM Setup Preferences <br /> Status Alarms Control Reports <br /> Dispenser Dispenser Status TS-VFM <br /> 1 Idle OperaSonal MkroiOl Internet Explore <br /> 2 Idle Operational Z) Do you re*wart to enkle DspKW4 <br /> Carxd <br /> 3 Idle O a <br /> 4 Shutdown Operational <br /> 5 Idle Operational <br /> 6 Idle Operational <br /> Common <br /> Pressure Sensor <br /> Ullaae Pressure <br /> Note: If a dispenser shutdown was caused by poor vapor collection, you will only be able to enable one dispenser at a <br /> time. If the shutdown was caused by a pressure failure, you will be able to enable all dispensers at the same time <br /> by pressing any dispenser. <br /> II-23 <br /> GARB Approved IBM 11-INCBN Vapor Recovery Monitoring(VRM)-Executive Order VR-202 <br />