Laserfiche WebLink
have been made tight,all appliance valves are turned <br /> off,and any unconnected outlets are capped. <br /> After turning on gas,teal gas piping and connections to <br /> appliances forleakage with soapy water or bubble solution,and light all pilots. <br /> The appropriate BTUH input rating shall be marked by the manufacturer. <br /> Note:See Article 1,Section 4031 for label size and type of material. <br /> (h)An anti-siphon bap vent device shall be permitted for use only as a secondary vent in accordance with the following: <br /> (t)Installation of an anti-siphon trap vent device shall be in accordance with the terms of its listing. <br /> (2)An anti-siphon trap vent device shall be installed in an accessible location that provides a free flow of air for the device. <br /> (3)An anti-siphon trap vent device shall not serve more than two(2)futures. <br /> (4)An anti-siphon trap vent device shall not be used for more than two(2)consecutive fixtures before being vented to outside <br /> atmosphere. <br /> (5)An antiphon bap vent device that protects two(2)fixtures shall be drained,at a minimum,by a common 1.5 inch(38.1 mm) <br /> diameter drain. <br /> (6)An ant-siphon bap vent device shall not serve as a primary vent for toilets or holding tanks. <br /> (7)A fixture drain or main drain that bypasses a holding tank shall be vented by a primary vent in accordance with Chapter 9 of <br /> the California Code of Regulations,Tide 24,Part 5,California Plumbing Code(CPC). <br /> AUTHORRY: <br /> Nola:Authority cited:Sections 18825 and 18828,Health end Safety Code.Reference:SedlDns 18025 and 18028,Health and Safety Code. <br /> Manufactured Housing Regulations Page 4 Updated October 22,2012 <br /> Title 25,Chapter 3,Subchapter 2 <br />