Laserfiche WebLink
(c)Special purpose commercial modulars designed as bathrooms or shower room facilities only,may be provided with at least one <br /> (1)exterior door In each bathroom or shower room.This door shall not be used for any purpose that interferes with Its function as a <br /> means of egress. <br /> (d)Special purpose commercial modular units subject to the federa?motor vehicle safety standards as vehicles, shall be designed <br /> and constructed with an alternate or second exit.The alternate or second exit shag provide a clear unobstructed path of travel. Any <br /> equipment or fixtures shall not obstruct the alternate exit either inside or outside the unit required by Subsection(a). <br /> (e)The alternate exit shall be located either. <br /> (1)Jr.an area opposite the main exit door or in the rear of the special purpose commercial modular,with a net clear openable area <br /> of 5.7 square feet(0.53 m2).The minimum net clear operable height dimension shall be twenty-four(24)Inches(610 mm).The <br /> minimum net clear operable width dimension shall be twenty(20)inches(508 mm). <br /> (2)In the roof of the special purpose commercial modular,with unobstructed passage to a 24 x 24 inches(61 cm x 61 cm) <br /> minimum opening to the outside. <br /> (1)The bottom of the attemate or second exit required by Subsection(a)of this section shall not be more than four(4)feet(1.22 m) <br /> either above the floor of the special purpose commercial modular or above a readily accessible horizontal surface capable of supporting <br /> a weight of 300 pounds(136 kg). <br /> (g)The latch mechanism of any means of exit shall be operable by hand,and shall not require the use of a key or special tool for <br /> operation from the inside. <br /> (h)If an alternate or second exit is other than a standard door,it shall be labeled with the word°EXW wi0t one(1)inch(2.54 cm) <br /> minimum letters on a conhaisfing background. <br /> AUTHORITY: <br /> Noe:Authority died:Sedan 18015,Hea.Mh and Sa*Code.Reference:Sections 18025 and 18028,Heats mtl Set*Code. <br /> §4529.Coiling Height. <br /> (a) Each special purpose commercial modular shall have a minimum ceiling height of seventy-four(74)inches (188 cm)over the <br /> inside aisle-way portion of the unit. <br /> (b)Ught furfures are allowed to protrude a maximum of three(3)inches(7.62 cm)into minimum ceiling height <br /> AUTHORITY: <br /> Nnk:Aulhodty rived:Section 18015,Health and Safety Code.Reference:Sectim 18025 and 18028,Heats end Safety Cade. <br /> §4530.Room Dimensions and Construction. <br /> (a)There shall be a clear, unobstructed height over the aisle-way portion of the unit of at least 74 inches(188 cm)from Boor to <br /> ceiing,and a minimum of 30 inches(76 cm)of unobstructed horizontal aisle space. <br /> (b)Special purpose commercial modulars designed for public accommodation shall comply with the accessibility,provisions of the <br /> Cal'domia Code of Regulations,Title 24,Part 2,California Building Code(CBC),Chapter 11 B. <br /> AUTHORITY: <br /> Note:Auliorrty dfed:Secton 18015,Health and Safety Code.Reference:Sections 18025 and 18028,Health and Safety Code. <br /> §4531.Glass and Glazed Openings. <br /> The provisions of Chapter 24 of the California Code of Regulations,Title 24,Pad 2,California Building Code (CBC)shall apply to <br /> glass and glazing in all special purpose commercial modulars riot subject to the federal standards under the National Traffic and Motor <br /> Vehicle Safety Act of 1966. <br /> AUTHORITY: <br /> Note:Authority pied:Sedan 18015,HeaIM and Safety Code.Reference:Sections 18025 and 18028.Heath and Safety Code. <br /> §4532.Electrical. <br /> (a)Except as provided in Subsection(b),the provisions of Article 3,Subarticle 3,of this subchapter,and the following shall apply to <br /> electrical equipment and installations of all special purpose commercial modulars. <br /> (b)Each special purpose commercial modular shall have an appropriately rated branch circuit panelboard.The panelboard shall be <br /> installed so that its bottom is at least twenty-four(24)inches(61 cm)above the Boor,unless the panelboard is lusted for installation in <br /> wet locations. <br /> AUTHORITY: <br /> Note:Authacity cried:Sectimi 18015,Heath and Safety Code.Reference:Sections 18025 and 18028,Haab and Safety Cade. <br /> §4533.Mechanical. <br /> (a) Except as provided in Subsections (b) and (c), the provisions of Article 3, SubAde 4, of this subchapter, shall apply to <br /> mechanical equipment and installations of all special purpose commercial modulars. <br /> Manufactured Housing Regulations Page 2 Updated October 22,2012 <br /> Title 25,Chapter 3,Subchapter 2 <br />