HCD SPCM FQQO PREPARATION UNIT CHECKLIST G-- —L , Kra Cite <br /> No <br /> FOR REFERNCE DPILY HSC Part 7 <br /> 2 T25 CCR J Yes _ <br /> MECHANICAL HOODS–CCR T24 CMC§508 <br /> •Are hoods installed all: • Mechanical exhaust ventilation <br /> Deep fat fryers;broilers;fry grills;steam- equipment provided over all cooking §114149.1(a) <br /> Hoods jacketed kettles;hot-top ranges;ovens; CMC§508.1 equipment?As required to effectively §114149.1(b) <br /> B80s;rotisseries;dishwashing machines; remove: §114149.1(c) <br /> and,similar equipment in a food-processing Cooking odors;smoke;steam;grease; §114149.1(4) <br /> establishment? heat;and,vapors. <br /> MECHANICAL HOODS SEAMS/JOINTS–CCR T24 CMC§808 <br /> • Seams,joints,and penetrations of the hood <br /> enclosure–Do they have a fiquid-tight CMC§508.2 <br /> continuous external weld to the hood's lower INFPA 95:5.1.21 <br /> outermostperimeter? <br /> • Seams,joints,and penetrations–Permitted <br /> to be internally welded;is the weld is formed CMC 5508.21 <br /> smooth or ground smooth,so it doesn't trap INFPAW5.1.31 <br /> cease,and is cleanable? <br /> •Are the internal hood joints,seams,fitter <br /> support frames,and appurtenances CMC§508.22 <br /> attached inside the hood sealed or grease- INFPA95:&IA1 <br /> fight? <br /> •Are the penetrations are sealed by devices <br /> that are listed for such use and whose CMC 5508.23 <br /> presence does not detract from structural tWPA9e5.1.51 •All seams in the duct completely tight <br /> integrity? to prevent the accumulation of grease? <br /> •Are the listed exhaust hoods,with or without • Construction joints/seams tightly fitted <br /> exhaust dampers constructed of materials CMC§508.24 1 sealed so as to be easily cleanable. <br /> required by the listing? <br /> p1FPA9a51.q Silicone sealant or equivalent <br /> •Are the fisted exhaust hoods assembled in CMC§508.2.5 waterproof compounds are acceptable, <br /> accordance with the listing requirements? INFPA 96:&1.71 provided that the gap is smaller than <br /> •Are the eyebrow-type hoods over gas/ W and applied smooth so as to §114149.2(1) <br /> electric ovens(when permitted)have a duct prevent the entrance of liquid waste or §114301(2) <br /> Seams t constructed as required in§510.0 from the CMC§508.2.6 vermin §114149.2(1) <br /> flue(s)connected to the hood canopy p1FPA9a5.isil . All seams in the duct completely light §114301(2) <br /> Joints oven <br /> upstream lue of the exhaust? to prevent the accumulation of grease? <br /> • Construction joints!seams tightly fitted <br /> • Is the duct connecting the oven Bue(s)to the CMC§508.2.7 !sealed so as to be easily cleanable. <br /> hood canopy connected with continuous 09FRA9a5.1.d21 Silicone sealant or equivalent <br /> weld or have a duct-to-duct connection? waterproof compounds are acceptable, <br /> • Does the insulation materials other than provided that the gap is smaller than <br /> electrical insulation shall have aflame 1/0 and applied smooth so as to <br /> spread rating of 25 or less when tested in CMC§508.2.8 prevent the entrance of liquid waste or <br /> accordance with UL 723,Standard for Test INFPA95:5.1.91 vermin <br /> for Surface Burning Characteristics of <br /> Building Materials? <br /> . Does the adhesives or cements used in the <br /> insta0ation U insulating materials comply CMC§508.29 <br /> with the requirements of§508.2.8,when INFPA9e51.1aJ <br /> tested with the specific insulating material? <br /> •Are the penetrations sealed with rated CMC§506.2.10 <br /> devices in accordance with the J MC§508.2.1J <br /> requirements of 508.2.117 <br /> Are the devices that require penetration of .27 <br /> 5061 <br /> the hood listed in accordance with UL 1978, pCMC C 508.11 1 <br /> Standard for Grease Ducts? <br /> EQUIPMENT ON ROOFS–CCR T24 CMC§903.8/304.0 <br /> Roof Access ' Equipment/appliances located on roofs or CMC§304.1 <br /> elevated locations are accessible? PNPPA5f:.9A3.11 WA WA <br /> Roof Support • Roofs with equipment are capable of CMC 303.8.12 WA WA <br /> supporting the additional load? <br /> . Is there a minimum of 6between any part <br /> Guards or of the equipment and the edge of the roof? CMC 303.8.1.5 WA WA <br /> Rails If not–Is there a guard or a tail a min of 42' <br /> tall on the exposed side? <br /> . If building height is more than 15'–Is roof CMC§304.1.2 NIA WA <br /> access from the inside? <br /> Inside • Is there a minimum of 6'between any part <br /> Access of the equipment and the edge of the root? 122 WA WA <br /> If not–Is there a guard or a rail a minimum §304.1.22 <br /> §304.19.4 <br /> of 42•tall on the exposed side? <br /> • Equipment has at least 30'working CMC <br /> Work Area Uearance in front of the service panel? §303.8.1.1 NIA WA <br /> Page 6 of 10 <br />