Laserfiche WebLink
S h N�I O n QU <br /> IN Environmental Health Department <br /> !iICV OJU 1Ni TYE+1 <br /> 15. Entrance door must be self-closing (114303) <br /> 16. Second exit opposite main exit door, or roof, or rear, with at least 24" x 36" of unobstructed <br /> passage. Exit shall be labeled "Safety Exit" in letters at least 1 inch high. (114323(f)) <br /> 17. Clear unobstructed height over aisle way at least 74 inches from floor to ceiling, and <br /> unobstructed horizontal aisle space at least 30 inches during operation hours. (114321) <br /> 18. Sink, warewash, 3-compartment, at least 12"x12"x10" deep, or 10"x14"x10" deep <br /> (114313(a)) <br /> 19. Sinks warewash, are stainless steel with mixed hot/cold faucets and swivel spigot capable <br /> of serving all compartments. (114313(c) <br /> 20. Sink warewash drainboards, both sides with slope of 1/8" per foot, and size at least one of <br /> the sink compartment. (114313(b)) <br /> 21. Sink, handwash, at least 9"x9"x5 deep (114311(a)). <br /> 22. Sink, handwash, separated from warewash sink by metal splashguard at least 6" from back <br /> edge of drainboard to front edge, unless they are separated by 24" or more. (114311(b)) <br /> 23. Coffee urns, deep fat fryers, steam tables, and similar equipment shall have positive closing <br /> lids with secure latch mechanism that will prevent excessive spillage. (114323(b)) <br /> 24. Floors, walls, and ceilings of all enclosed food preparation areas shall have impervious, <br /> smooth, and easily cleanable surfaces. (114301(g)) <br /> 25. Floor and wall junction shall be coved with 3/8" minimum radius caving, and floor surface <br /> extends up at least 4 inches. (114301(g)) <br /> 26. Floor mounted equipment sealed to floor or at least 6" off the floor on easily cleanable legs <br /> and feet. (114301(g)). <br /> 27. Equipment sealed together, or spaced a minimum of 4" apart from each other. (114301 (g)) <br /> 28. Equipment joints and seams shall be tightly fitted and sealed; silicone sealant or waterproof <br /> compounds if gap is smaller than % inch. (114301(b)) <br /> 29. No exposed threads, nuts, or rivets that interfere with proper cleaning. (114301(g)) <br /> 30. Gas-fired appliances shall be insulated to prevent excessive heat buildup and injury. <br /> (1 14323(g)) <br /> 31. 10 BC-rated fire extinguisher (114323(c)) <br /> 32. tight bulbs and tubes enclosed in plastic safety shield or equivalent. (114323(c)) <br /> 33. Pass through windows shall be limited to 216 square inches (or limited to 432 square <br /> inches if equipped with air curtain, shall be no closer than 18 inches from each other. <br /> 34. Each opening shall be equipped with self-closing solid windows or screens (screen shall be <br /> at least 16 mesh/ inch 114259.2). <br /> 35. Obtain a State Mobile Food Preparation Unit "Insignia" if necessary. Contact State Housing <br /> and Community Development for approval of your commercial coach at (916) 255-2501. <br /> The EHD must be kept informed of the construction progress. A final inspection must be performed, <br /> operating permit fees paid, and approval to operate granted prior to opening for business. All equipment <br /> must be installed and thorough cleaning completed prior to the final inspection. Inspections must be <br /> scheduled at least 48 hours in advance. Charges for additional inspections, re-inspections and/or <br /> consultations may be assessed at the EHD hourly rate of $152 per hour. <br /> Any item(s) inadvertently overlooked in the plan check process, which is not in compliance with <br /> applicable State laws, and/or city or county ordinance codes, shall be constructed or reconstructed upon <br /> request of the EHD. Inferior workmanship, equipment, or materials will not be accepted for the <br /> 2of3 <br />