NOTE NOTE
<br /> rte.
<br /> WALKS & SIDEWALK NOTES 1, FLOOR(S) OR LANDINGS) ARE NOT MORE THAN 1/2' LOWER THAN THE
<br /> A, MINIMUM 30' X 48' CLEAR SPACE IS PROVIDED IN FRONT OF SINK
<br /> A. WALKS AND SIDEWALKS SHALL HAVE A C❑NTINU❑US COMMON SURFACE N❑T60" MIN THAT ALLOWS FORWARD APPROACH, TOP OF THE THRESHOLD AT DOORWAY.
<br /> INTERUPTED BY STEPS OR ABRUPT CHANGES IN LEVEL OF THE FLOOR, SIDEWALK
<br /> OR WORKING SURFACE, lo
<br /> B. REQUIRED CLEAR SPACE ADJ❑INS OR OVERLAPS AN ACCESSIBLE 2, CHANGE IN LEVEL BETWEEN 1/4" AND 1/2' IS BEVELLED AT A
<br /> NOTE LEVEL CHANGES OF 1/4' OR LESS MAY BE VERTICAL, ROUTE AND EXTENDS 19' MAX, UNDER LAVATORY, GRADIENT OF 112, NOTE, A 1/4' MAXIMUM VERTICAL EDGE IS ALLOWABLE C�
<br /> AT THRESH❑LDS,
<br /> B. SLOPE IN THE DIRECTI❑N OF TRAVEL DOES NOT EXCEED 120 (5,0%) GRADIENT, Li Li C, LAVAT❑RIES ADJACENT TO SIDEWALL SHALL HAVE 18' MIN, FROM
<br /> C. CROSS SLOPE DOES NOT EXCEED 1150 GRADIENT (2,0%) w 3, DOORMATS ARE SECURELY ATTACHED (ANCHORED OR RECESSED,)
<br /> WALL TO CENTER OF LAVATORY, Q 0
<br /> D. 48' MINIMUM WIDTH OF WALKWAYS, � 0 0 � cu
<br /> E. NO GRATINGS (IF GRATINGS ARE NECESSARY, GRID OPENINGS AREA A. � 4, MAXIMUM HEIGHT ❑F DOORMATS IS 1/2', ALL GENDER
<br /> F. WALKS WITH C❑NTINU❑US GRADIENTS SHALL HAVE LEVEL AREAS OAT LEAST 5' Q z Q D, SINK IS A MAXIMUM OF 6-1/2' DEEP, MEN Drawn:
<br /> IN LENGTH EVERY 400', z � z Li w WOMEN RESTROOM
<br /> z u ZERTUCHE
<br /> G, ACCESSIBLE ROUTES WITH LESS THAN 60' X 60' AT LEAST EVERY 200' o � Q oE, KNEE CLEARANCE UNDER SINK IS A MINIMUM ❑F 27" HIGH AND 30' 5, GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN� m: u� DRAFTING & DESIGN
<br /> c� WIDE AND PR❑VIDES AN ABSOLUTE DEPTH OF 19' UNDERNEATH THE ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS, WALKS, RAMPS,
<br /> NOTE AT INTERSECTION ❑F TWO CORRIDORS ❑R WALKS IS AN ACCEPTABEL o' xoRACIO zERTucxE
<br /> o z STAIRS AND CURB RAMPS ARE STABLE, FIRM AND SLIP RESISTANT,
<br /> PASSING SPACE, o _j LD 1050 N.CARPENTER,SUITE-J
<br /> z °_����� MODESTO,CA95351
<br /> H, SURFACE IS SLIP RESISTENT, 3 F, DRAIN AND HOT WATER PIPING IS INSULATED OR CONFIGURED TO TYPICAL f�ETI�CO��M ���� I�NQ�E 6, CARPETS ❑R CARPET TILES ARE SECURELY ATTACHED AND HAVE A (209)507-6036
<br /> I. LEVEL CHANGES BETWEEN 1/4"-1/2' ARE BEVELED A MINIMUM OF 112, � j PREFENT BURNING USER, LEVEL LOOP, TEXTURED LOOP, LEVEL-CUT PILE OR LEVEL-CUT/UNCUT horacio@zertuchedrafting.com
<br /> HAZARDS AND PR❑TRUDING OBJECTS D PILE WITH PILE NOT EXCEEDING 1/2' HEIGHT,
<br /> z G, THERE ARE NO SHARP OR ABRASIVE ELEMENTS UNDER SINK, NOTES: DOOR-MOUNTED
<br /> 1. ABRUPT CHANGES IN LEVELS, EXCEPTED BETWEEN A WALK OR SIDEWALK AND <I 7, EXPOSED EDGES OF CARPET ARE FASTENED TO FLOOR SURFACES AND 1,-ON DOORWAYS LEADING TO SIGNAGE s-=/
<br /> AN ADJACENT STREET OR DRIVEWAY, EXCEEDING FOUR INCHES (4') IN VERTICALIN H, FAUCETS ARE LEVER TYPE, ELECT❑NICALLY ACTIVATED OR HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE, SANITARY FACILITIES THE APPROPRIATE TO
<br /> HEIGHT, SUCH AS PLANTERS OR FOUNTAINS, LOCATED IN OR ADJACENT TO WALKS, SYMBOLS TO BE PROVIDED
<br /> SIDEWALKS OR OTHER PEDESTRIAN WAYS, REQUIRE WARNING CURBS A MINIMUM OF SIDE DOOR SWING APPROVED SELF CLOSING VALVES (MIN 10 SECOND OPEN FLOW) ARE 12" EQUILATERAL ROOM USE, o°o
<br /> 6' IN HEIGHT ABVE THE WALKWAY SURFACE, DOORS IN ANY P❑SITI❑N MAY OUT, 8, GRATINGS LOCATED IN WALKING SURFACES HAVE GRID ❑PENIGS A TRIANGLE FOR MEN OR 12'
<br /> ENCROACH INT❑ THE 60' DIAMETER I, FAUCETS ARE OPERABLE WITH ONE HAND AND D❑ NOT REQUIRE MAXIMUM OF 1/2 WIDE IN ONE DIRECTI❑N, DIAMETER CIRCLE FOR L�
<br /> A. ANY OBSTRUCTION THAT OVERHANGS A PEDESTRIAN WAY SHALL BEAAMAX12' CLEARANCE TIGHT GRASPING PINCHING ❑R TWISTING ❑F THE WRISTWOMEN, 1/4' THICK
<br /> , , Q
<br /> MINIMUM ❑F 80' ABOVE THE WALKING SURFACE (MEASURED FROM THE BOTTOM OF 9, WHEN GRATINGS HAVE ELONGATED OPENINGS THEY SHALL BE PLACED CENTERED ❑N DOOR Ln
<br /> THE OBSTRUCTION) SO THAT THE LONG DIMENSION IS PERPEDICULAR TO THE DOMINENT 58'-60' AF, a o 0
<br /> B. IF VERTICAL CLEARANCE OF AN AREA ADJ❑INING AN ACCESSIBLE ROUTE IS J. 5 LB, MAXIMUM FORCE REQUIRED TO ACTIVATE C❑NTR❑LS, CONTRASTING COLOR WITH �
<br /> REDUCED TO LESS THAN 80', A BARRIER TO WARN BLIND OR VISUALLY IMPAIRED DIRECTI❑N OF TRAVEL, DOOR, ,I
<br /> PERSONS IS PR❑VIDED, K. MIRR❑R SHALL BE MOUNTED S❑ BOTTOM EDGE IS NO HIGHER THAN Ln�
<br /> C. SIDWALKS/WALKS SHALL BE CLEAR OF HAZARDS, ADA W.C. CLEARANCE 40' TO FL❑❑R, l n V
<br /> 2, OBJECTS PROJECTING FROM WALLS WHOSE LEADING EDGES ARE BETWEEN 27' SCALE:NTS ( J
<br /> AND 80' ABOVE THE FINISHED FLOOR D❑ NOT PROTRUDE MORE THAN 4' INT❑ MAT CARPETING MUST CONSIST ❑Fi
<br /> WALKS, HALLS, C❑RRID❑RS, PASSAGEWAYS OR AISLES, (OBJECTS WHOSE LEADING - LEVEL LOOP
<br /> EDGESARE AT OR BELOW 27' ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY - TEXTURED LOOP
<br /> - LEVEL CUT PILE OR l J
<br /> A. PR❑TRUDING AB❑JECTS MAY NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN - LEVEL CUT / UNCUT PILE WHITE SYMBOLS AND LETTERS ON A l J
<br /> ACCESSIBLE ROUTE OR MANEUVERING SPACE, BLUE BACKGROUND, TYPICAL,
<br /> B. FREE STANDING OBJECTS MOUNTED ON POST OR PYLONS OVERHANG 12'
<br /> MAXIMUM FROM 27' TO 80' ABOVE THE FINISHED FL❑❑R, NOTE C, WALKS, HALLS, C❑RRID❑RS, PASSAGEWAYS, AISLES OR OTHER CIRCULATI❑N 1/2' MAX, PILE THICKNESS CD
<br /> SPACES SHALL HAVE A MINIMUM OF 80' CLEAR HEAD RO❑M,
<br /> D. IF VERTICAL CLEARANCE OF AN AREA ADJ❑INING AN ACCESSIBLE ROUTE IS 1, GRAB BARS AT WATER DOORMAT MUST BE D �� �� MEN
<br /> REDUCED TO LESS THAN 80', A BARRIER TO WARN THE BLIND R VISSUALLY
<br /> CLOSET. ONE AT SIDE 42' IF PILE HEIGHT SECURELY ANCHORED a
<br /> IMPAIRED SHALL BE PR❑VIDED, LONG EXTENDING 24' IN 1-1/4' TO x EXCEEDS 1/4' OR RECESSED INTO cu MEN WOMEN LL GENDE RESTROOMS RESTROOMS a
<br /> DOORS AND DOOR HARDWARE FRONT OF WATER CLOSET 1-112' 1-1/2' DIA GRAB Tr I i x THEN EDGES MUST DOOR LANDING
<br /> 1, MINIMUM OF 3' IN WIDTH, 6'-8' IN HEIGHT, OR AT REAR OF WATER MIN BAR z z HAVE BEVELED TRIM 6
<br /> 2, OPENS A MINIMUM OF 90 DEGREES, CLOSET 36' LONG BOTH CLEAR z z o CORRESPONDING GRADE II
<br /> 3, CLEAR WIDTH OF THE DOORWAY IS 32' MINIMUM, MOUNTED 33'-36' A.F.F. FIRM PA MEN •• BRAILLE
<br /> 4, DOUBLE D❑ORS/AUTOMATIC DOORS - AT LEAST ONE DOOR MUST COMPLY WITH TO TOP OF GRIPPING SURFACE, OBSTRUCTIONS
<br /> A, B, C ABOVE.
<br /> - - -
<br /> 5, BOTTOM 10' OF DOOR HAS A SMOOTH, UNINTERRUPTED SURFACE (KICK PLATE) 12' MIN, a_ TYPICAL RESTROOM WALL SIGNAGE
<br /> 6, EFFORT TO OPERATE DOORS IS WITHIN PRESSURES ALL❑WED, 2, BARS SHALL BE 1-1/4"
<br /> A. INTERI❑R DOORS - 5 POUNDS MAXIMUM PRESSURE TO OPERATE, TO 1-1/2' IN DIAMETER TOP ❑F BAR CLEAR, X � o
<br /> B. EXTERI❑R DOORS - 5 POUNDS MAXIMUM PRESSURE TO OPERATE, WITH 1-1/2' CLEARANCE T❑ 8" MIN KNEE z WALL MOUNTED TACTILE SIGN TO
<br /> C. FIRE DOORS - 15 POUNDS MAXIMUM PRESSURE TO OPERATE, CLEARANCE X 30" 6" MIN TOE CLEARANCE cu
<br /> 7, AUTOMATIC DOORS MUST PR❑VIDE A MINIMUM OF 32' CLEARANCE WHEN FULLY WALL, O cu BE LOCATED ON LATCH SIDE OF
<br /> OPEN. zQ WIDE
<br /> 3, 12' CLEARANCE REQUIRED TOP OF WC W z DOOR SWING MOUNTED AT 48'MIN,
<br /> TANK/ J Q Q AFF TO BASELINE OF LOWEST mZ
<br /> DOOR HARDWARE BETWEEN THE TOP OF THE ��v 1 MIN DE TH 1'. BRAILLE CELL, AND 60' MAX, AFF °
<br /> 1, EXIT DOORS AREA ARE OPERABLE FROM THE INSIDE WITH❑UT GRAB BAR AND ANY OBSTRUCTIONS, T❑ THE BASELINE OF THE HIGHEST 9" 0 '*
<br /> THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. I m 30" WIDE FINISHED FLOOR COMPRESSED CARPET 1/4' MAX, LINE ❑F RAISED CHARACTERS, o
<br /> 2, OPERABLE WITH A SIGLE EFFORT (EX, LEVER TYPE, PANIC BARS OR THRESHOLD BELOW THRESH❑LDMIN w W
<br /> PUSH/PULL TYPE, m -- MOUNT SIGNAGE AT 9' MIN, FROM a a
<br /> 3. OPENING HARDWARE IS CENTERED BETWEEN 34' AND 44' ABOVE FINISH FLOOR, 4, BAR FASTENERS AND I m CENTERLINE TO DOOR JAMB,
<br /> 4, DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED S❑ THAT FROM AN MOUNTING SUPPORT SHALL
<br /> OPEN P❑SITI❑N OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO BE ABLE 1-0 WITHSTAND Q
<br /> A P❑SITI❑N OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM, 250 LBS, P❑INT LOAD IN WALL Q
<br /> 5, CL❑SING SPEED SHALL BE ADJUSTED S❑ THAT FROM AN OPEN P❑SITI❑N OF 90° BENDING SHEAR TENSI❑N, CTI 0
<br /> THE TIME REQUIRED TO MOVE THE DOOR TO A P❑SITI❑N OF 12 DEGREES FROM W 0� = N
<br /> ROTATION IN FITTING NOT
<br /> THE LATCH IS 5 SECONDS MINIMUM, � uJ �
<br /> ALLOWED. LAVATORY CLARENCE DOOR THRESHOLD IGNAGE
<br /> 6, OPERABLE FORCE FOR ALL NON-RATED INTERIOR AND EXTERIOR DOORS SHALL BE 2 3 (4)AW- W �
<br /> 5 POUNDS MAXIMUM, GRAB BAR SECTION SCALE:NTS SCALE:NTS SCALE:NTS = W � �
<br /> 7, ACCESSIBLE DOOR HARDWARE SHALL BE LOCATED 34'-44' AFF, 5, SURFACE ❑F WALL (� = CD Q
<br /> ADJACETN TO GRAB BAR IS W () � = 0
<br /> 8. DOOR ❑PERATI❑N HARDWARE AND L❑❑KING HARDWARE SHALL NOT REQUIRE TIGHT TO BE FREIE OF SHAR ORN❑TES 0 W U
<br /> GRASPING, PINCHING, OR TWISTING OF THE WRIST, D
<br /> ABRASIVE ELEMENTS, Z Iql- 0
<br /> NOTES 1, SIGNS SHALL BE DISTINCTLY DIFFERENT IN COLOR AND U) Z J
<br /> CONTRAST, COLOR TO BE SELECTED BY ARCHITECT, ::) >
<br /> 1, HEIGHT OF WATER CLOSET SEAT SHALL BE 17' TO 19' A.F.F. Q J
<br /> 2, SIGN ON GLASS TO BE CLEAR BACKGROUND WITH WHITE z LL W
<br /> ETCHED H/C SYMBOL o a
<br /> 4 O" GRAB BAR DETAIL 2, FLUSH CONTROL FOR ALL WC TYPES SHALL BE LOCATED ON THE OPEN g„
<br /> MIN. 5 SIDE OF TOILET COMPARTMENT, 3, THE INTERNATI❑NAL SYMBOL OF ACCESSIBILITY SHALL
<br /> SCALE:NTS CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND, THE
<br /> 3, TOILET PAPER DISPENSER ALLOWS C❑NTINU❑US PAPER FLOW BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL
<br /> z 10" HOT DIPPED SSTANDARD 5998.
<br /> ALV.LAG BOLTS (N) 20d NAIL, NAILED AND DOES NOT CONTROL DELIVERY,
<br /> - @ EA, SIDES 0 RAFT R BELOW 4, WHEN RAISED CHARACTERS OR SYMBOLS ARE USED, THEY
<br /> - 52' MINIMUM WHEN WATER CLOSETS ARE IN STALLS SHALL CONFORM TO THE F❑LL❑WING, FINISH SURFACE ui
<br /> (E) PARA ET WALL - 54' MINIMUM WHEN WATER CLOSETS ARE NOT IN STALLS, C3 TO MATCH
<br /> A. PICT❑RAL SYMBOLS (PICT❑GRAMS) SHALL BE ACCOMPANIED � (E)SLAB �WIDTH ARIES� (E)SLAB
<br /> 4x URB
<br /> (SUCH AS IN SINGLE ACC❑M❑DATI❑N ROOMS OR OPEN TOILETING BY THE EQUIVALENT VERBAL DISCRIPTI❑N PLACED DIRECTLY U.
<br /> U.
<br /> (N) 2x6 CELING SITUATIONS,) BELOW THE PICT❑GRAM, THE BORDER DIMENSI❑N OF THE
<br /> (E) ROOF (E.) ROOF JOIST PICT❑GRAM SHALL BE A MINIMUM OF 6' IN HEIGHT, ACCESSIBILITY
<br /> (N) 4x10 W BM. Z @ 12 0.C. B. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A SIGN ♦ `
<br /> WIDTH-T❑-HEIGHT RATIO OF BETWEEN 315 AND 111 AND A STROKE v
<br /> WIDTH-T❑-HEGHT RATI❑N BETWEEN 115 AND 1110, DOWEL INTO EXISTING DOWEL INTO EXISTING
<br /> C. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR LL FOOTING w/3-#4 EMBEDDED FOOTING w/3-#4 EMBEDDED
<br /> INTO c FTG w/ INTO EXISTING FTG W/
<br /> BACKGROUND, EITHER LIGHT CHARACTERS ON A DARK SI SET ESI Q
<br /> 36" MIN. BACKGROUDN ❑R DARK CHARACTERS ❑N A LIGHT BACKGROUND, Q MPSON SET EPDXY MPSON SET EPDXY
<br /> E CEILING RAMING D. CHARACTERS AND NUMBERS ON SINGS SHALL BE SIZED #3 BAR a 18
<br /> ' '^
<br /> ( ) 54" MIN 6" MAX ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY ARE TYP NUMBER VARIES (J J
<br /> MET. CHANNEL 42' MIN 24" 12" TO BE READ, THE MINIMUM HEIGHT IS MEASURED USING AN
<br /> W/ WASHER 12
<br /> 20 GAUGE METAL STRAP TOILET PAPER MIN IN UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED, FOR
<br /> & LOCKNUT MAX 36" MAX HOLDER WITH❑UT SIGNS SUSPENDED OR PROJECTED ABOVE THE FINISH FLOOR. i
<br /> W/1" DIA. SUPPORT ROD lo STOPS 17"- 8" THE MINIMUM CHARACTER HEIGTH SHALL BE 3', Q
<br /> 4x6 D.F. SUB JOIST ON 7`9 E, CONTRACTED GRADE 2 BRAILLE SHALL BE USED
<br /> BOTH SIDES W/ U HANGER (E)GYP.BD. TOP OF BAR ADJACENT WHEREEVER BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN LJ1
<br /> C===TWALL OTHER P❑RTI❑NS ❑F THESE REGULATI❑NS, D❑TS SHALL BE 1/10' J
<br /> EXHAUST PLENUM 16 GA N 2x6 BLK'G ON CNETERS IN EACH CELL WITH 2/10' SPACE BETWEEN CELLS, Q
<br /> WELDED CONSTRUCTION ( ) 2X4 WOOD STUDS @ 16" O.C. DOTS SHALL BE RAISED A MINIMUM ❑F 1/40' ABOVE THE
<br /> (TYP.) DUCT W/ ONE LAYER BACKGROUND, ui
<br /> CEILING GYP.BD. OF 3M FIRE BARRIER DUCT 24"MIN, ENTRANCE SIGNAGE SLAB PATCH DETAIL
<br /> WRAP 615+, 3" PERIMETER - M 7 �j
<br /> & LONGITUDINAL OVERLAP �p SCALE:NTS SCALE:NTS
<br /> B
<br /> 4 - 1/2" DIA. HOOD - X .-I 1/2 GYPSUM BOARD \A NOTES
<br /> SUPPORTED RODS SIDE VIEW FRONT VIEW 00
<br /> SEE A-4 FOR DETAILS 1, MINIMUM 30' X 48' CLEAR FLOOR OR GROUND SPACE IS PROVIDED TO ALLOW FORWARD
<br /> GENERAL OR PARALLEL APPROACH TO ACCESSORIES,
<br /> 2 ROWS >_
<br /> 4" SCREWS FLOOR MOUNTED WATER CLOSETS 2, ❑NE FULL UNOBSTRUCTED SIDE ❑F THE CLEAR FL❑❑R ❑R GROUND SPACE ADJ❑INS OR M
<br /> W
<br /> (E.) CONC. SLAB PDPW-300 FASTENER LOAD, THERE SHALL BE A FLOOR
<br /> 18" CLEAR AT
<br /> OR LANDING ON EACH SIDE OF A INTERIOR DOOR 3, MIRROR TO BE MOUNTED 40' MAX FROM THE FINISH FLOOR TO THE BOTTOM EDGE
<br /> 2X TREATED PLATE 54 MIN 6" MAX DOOR. OF MIRR❑R REFLECTING SURFACE,
<br /> FIN. FLOOR36" MIN, ( 60" MIN
<br /> 42" MIN11_71
<br /> 12„ 4, OPERABLE PARTS (INCLUDING C❑IN SLOTS) OF ALL FIXTURES OR ACCESS❑RIES ARE MOUNTED w
<br /> NOTE: 1, FLOOR ❑R LANDING EACH
<br /> CLEARANCE "X" MAX 36" MAX TOILET PAPER 24" 12" SIDE OF THE DOOR SWING IS 2% MAX SL❑PE A MAXIMUM HEIGHT ❑F 40' AB❑VE FINISH FL❑❑R (I.E. S❑AP DISPENSERS, TOWELS, TOILET L z
<br /> DISPENSERol
<br /> IN ANY SEAT COVERS, AUTO DRYERS, SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES ETC,)
<br /> LESS THAN 12" MIN IN LEVEL AND CLEAR, z u
<br /> si ' 7"-9" DIRECTION EXCEPT COAT HOOKS PERMITTED AT 48' AFF, w
<br /> REQUIRES CEILING (E) $ TYPE X" ADJACENT
<br /> ENCLOSURE PANNEL GYP. BOARD NOTE : FASTENERS PLACED @ 6" FROM END OF SILL PLATE WITH WALL 2. LEVEL AREA IN THE a
<br /> MAXIMUM SPACING O F 24" O.C. % 5, CONTROLS AND OPERATING MECHANISMS ARE OPERATE THE ONE HAND AND D❑ NOT
<br /> 17"-18" DIRECTION ❑F THE DOOR SWING IS REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST, Date:
<br /> z W MINIMUM OF 60" IN LENGTH, PULL SIDE
<br /> z J 6, THE FORCE REQUIRED TO ACTIVATE CONTROLS IS 5 LBS, MAXIMUM,
<br /> Revisions:
<br /> v o) z � 3, LEVEL AREA ❑PP❑SITE THE
<br /> 24" MIN o o DIRECTI❑N ❑F THE D❑❑R SWING IS 7 MAX TABOVE FLOOR RECOMMENDED,)HOOKS AND SHELVING ARE LOCATED WITHIN APPROPRIATE REACH RANGES (48' 09/01/2019
<br /> i� MINIMUM OF 44'-48' IN LENGTH, z
<br /> DEPENDENT UPON DIRECTI❑N OF 8. IF MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE HAS A USABLE SHELF NO
<br /> z 10/04/2019
<br /> DETAIL NOT USED APPROACH AND EXISTENCE OF HIGHER THAN 44' ABOVE THE FLOOR.
<br /> LATCH AND CLOSER.
<br /> (B) �A) L 2% MAX� 11/21/2019
<br /> WALL FRAMING DETAIL
<br /> 10FRONT VIEW 4, SURFACE SLOPE OF THE PUSH SIDE
<br /> SCALE:NTS SIDE VIEW EXTERI❑R LANDING LEVEL AREA SLOPE IN
<br /> ANY C� ❑o
<br /> 2 MAY SLOPE UP TO 1/4' PER 4g 2 DIRECTI❑N x O
<br /> FOOT IN ANY DIRECTI❑N FOR MI Q
<br /> WALL MOUNTED WATER CLOSETS DRAINAGE, Page No:
<br /> 0
<br /> 6 GRAB BAR & W.0 PAPER 8 DOOR CLARENCE 10 ACCESSORIES DETAILSA0
<br /> LOCATION SCALE:NTS SCALE:NTS SCALE:NTS
<br />
|