Laserfiche WebLink
WIRING METHODS CEC ART. 300 ELECTRICAL SPECIFICATIONS ELECTRICAL GENERAL NOTES J Q 0 <br /> CO � � 7- U.) M.� La <br /> Section 5,Electric Metering:General LUN @ o <br /> U SUPPORTS: 1. CONTRACTOR SHALL READ THE SPECIFICATIONS AND COMPLY WITH ALL REQUIREMENTS.THESE GENERAL LL <br /> �F U > 1. FURNISH ALL NECESSARY FOUNDATIONS, PADS,SUPPORTS, BACKING, ETC., FOR ALL ELECTRICAL NOTES ARE INTENDED TO ASSIST THE CONTRACTOR DURING EXECUTION OF THE WORK. HOWEVER THEY J W o N cel 0 I � � <br /> 101, Obstruction QJ w ENCLOSURES,CONDUITS AND EQUIPMENT,OR COORDINATE W/G.C. DO NOT COVER ALL OF THE SPECIFICATION REQUIREMENTS. Q Z V) X T" 111 <br /> Nearest Inside - 3 <br /> Nearest Inside 10" I Min. <br /> Corner or Other Above Meter G� J ~ Z Z � Q IL T� <br /> Corner or Other Min. Obstruction Obstruction I Q J 2. ATTACH ALL BOXES, CABINETS, ETC.TO WOOD WITH WOOD OR LAG SCREWS,TO METAL WITH MACHINE 2. THE DRAWINGS INDICATE THE PANEL BOARDS AND CIRCUIT NUMBER FOR EACH OUTLET, ELECTRICAL m 00 0 6 <br /> Obstruction Above Meter ---- - - w w SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS AND MACHINE SCREWS OR BOLTS. EQUIPMENT, ETC. THE EXACT LAYOUT AND CONFIGURATION OF THE BRUNCH CIRCUITS IS LEFT TO THE 0 W •� <br /> _ -t- - 9"Min. �P : z z CONTRco <br /> ACTOR WITHIN THE REQUIREMENTS ESTABLISHED HEREIN. LL J 1' w J <br /> r 9"Min. I G� M J > GROUNDING: J tW 0 •a <br /> I I � I See �P w Q w w w Q J 1. GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND SPECIFICALLY INCLUDING 3. LIGHTING BRANCH CIRCUITS SHALL NOT BE COMBINED WITH RECEPTACLES OR CONDUITS INTO MULTI-WIRE Q cp _ E <br /> I 75' Min. I Figure 5-1 �� LLE <br /> J J J U w w U = o <br /> U SWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC. BRUNCH CIRCUIT UNLESS SO INDICATED ON THE DRAWINGS. 0 - <br /> 75"*Min. Semi-Flush I Working Door I and P Q x m m m w w c o f <br /> Working I Meter Space (Open) I Table 5-1 U U Q U - Q CL `' o <br /> U (� (� z PANELBOARDS: 4. ALL CONDUITS PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS OR CEILINGS SHALL BE MADE WITH = B > <br /> Space I Installation I Height Enclosed I for Meter P� m J o o 0 <br /> w 1. ALL UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL SCHEDULE,WITH THE U.L. LISTED AND APPROVED MATERIALS AND METHODS AND SHALL COMPLY WITH 2016 CBC REQUIREMENTS Z <br /> Meter I Cabinet � U U w J = NUMBER AND SIZE OF BREAKERS AS INDICATED ON THE PANEL SCHEDULE. SINGLE POLE,TWO POLE,AND AND LOCAL ORDINANCE PER THE RECENTLY ADOPTED NEC. O c M <br /> Height I I Enclosure z Q w w U U ao - ID <br /> Installation THREE POLE BREAKERS SHALL BE BOLT-ON TYPE. MULTIPLE POLE BREAKERS SHALL HAVE COMMON O N o V <br /> Clear a Level I Clear and Level I Clearances 10 ® m ® INTERNAL TRIP CONNECTION. SINGLE POLE BREAKERS SHALL NOT BE TIED AT HANDLES TO FORM MULTIPLE 5. ALL CONDUITS PENETRATING THROUGH THE EXTERIOR WALLS AND ROOFS SHALL ALL BE SEALED LL N ? oo� U o <br /> ABOVE GROUND ® 00 <br /> L T <br /> Workspace Workspace (EXPOSED , CONCEALED OR ® ® ® POLE BREAKERS. THE PANEL DOORS SHALL HAVE FLUSH TYPE LOCKS,ALL LOCKS SHALL BE KEYED ALIKE WEATHER-TIGHT WITH U.L.APPROVED MATERIALS AND METHODS IN ACCORDANCE WITH CITY OF FREMONT Z0 0 LO rn o <br /> 30"Min. �� /�/ 36"Min. EMBEDDED IN BRICK OR PLASTER, • • • AND HAVE PRINTED DIRECTORIES INDICATING FIXTURES, EQUIPMENT,OR OUTLETS SERVED BY EACH AND U.B.C./C.B.C.STANDARDS. O Q t�-qt � o <br /> 30"Min. \\,�A� 36"Min. BREAKER. PANELS SHALL HAVE COPPER BUSSING. I� 04 o •L " <br /> \ Property Line THROUGH FRAMING) N� <br /> TO BE USED FOR BRANCH CIRCUITS 6. ALL ELECTRICAL WORK SHALL CONFIRM WITH LOCAL CODES,CEC,O.S.H.A.AND THE LATEST NEC Q <br /> Property Line or Obstruction U -0 o a co <br /> P Y ® TESTING: SPECIFICATIONS. POWER WORK TO COMPLY WITH PG&E REQUIREMENTS. = Q e e, <br /> or Obstruction Note:To allow the cabinet door to open fully UNDERGROUND a)C®4 ® 1. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND IMPROPER GROUNDS. LlJ ui li m u) i <br /> *78"minimum for installations other (900 or more),increase the 30"minimum-width (DIRECTLY BURIED) TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY FIXTURES OR 7. CONTRACTOR SHALL FURNISH&INSTALL ALL ELECTRICAL EQUIPMENT,WIRES,CONDUITS, CONNECTIONS, V) <br /> than individual,field-installed meter dimension of the meter working space,as EQUIPMENT ARE CONNECTED AND WHETHER SUCH TESTS INDICATE FAULTY INSULATION OR OTHER OUTLETS, ETC. NECESSARY TO ACHIEVE A COMPLETE ELECTRICAL INSTALLATION. WHERE ELECTRICAL Z U H _ _101) ( 3: <br /> panels. Increase the working-space necessary. DEFECTS,THEY SHALL BE LOCATED, REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. ROTATION DEVICES ARE REQUIRED BY CODE BUT NOT SHOWN, IT SHALL BE FURNISHED AND INSTALLED BY THE C) <br /> height for installations greater than Figure 5-4 OF ALL MOTORS SHALL BE CHECKED AND CORRECTED, IF NECESSARY,AFTER FINAL CONNECTIONS ARE CONTRACTOR AS THOUGH FULLY SHOWN AND SPECIFIED. U <br /> 66". Enclosed Meter Installation ABOVE GROUND D 10 C O MADE. <br /> Figure 5-3 (IN A RACEWAY OR CABLETRAY) ® ® ® 8. ALL NEW ELECTRICAL EQUIPMENT SHALL BE SECURELY FASTENED TO STRUCTURE(S)TO MEET SEISMIC <br /> Semi-Flush Meter Installation TO BE USED FOR FEEDER CONDUCTORS 2. DEMONSTRATE TO THE OWNER AND THE ENGINEER,THAT THE ENTIRE INSTALLATION IS COMPLETE, IN REQUIREMENTS FOR THE BAY AREA LOCATION. <br /> PROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN PROPERLY AND FULLY EXECUTED. STAMP: <br /> PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS. 9. ALL WORK SHALL BE INSTALLED IN NEAT,SAFE AND WORKMANLIKE MANNER. \VS D ARCl T <br /> PANELCLEARANCE IN DAMP, WET OR CORROSIVE 0 NAMEPLATES&IDENTIFICATION: 10. CONTRACTOR SHALL COORDINATE WORK WITH ALL TRADES TO AVOID CONFLICTS AND/OR DELAYS. •S\K B �,•.�FC� <br /> LOCATIONS • • INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC. NAMEPLATES SHALL BE q . <br /> SECURELY FASTENED TO THE EQUIPMENT WITH#4 PHILLIPS ROUND HEAD CADMIUM PLATED SELF-TAPPING 11. ALL LIGHTING SWITCHES, SHALL BE INSTALLED MAXIMUM AT 48"ABOVE FINISHED FLOOR TO CENTERLINE. <br /> SCREWS, BRASS BOLT,OR WITH A PLASTIC RESIN ADHESIVE GLUE,GOODYEAR"PLIEBOND"OR EQUAL. ALL RECEPTACLES OUTLETS SHALL BE INSTALLED AT LEAST 16"ABOVE FINISHED FLOOR TO CENTERLINE. <br /> �2e�1 <br /> WIRING METHODS: 12. CONTRACTOR SHALL PROVIDE A GROUND WIRE IN EACH CONDUIT WHETHER A GROUND WIRE IS SHOWN ON <br /> NOTES: C-2552 <br /> 1. AC CABLES CAN BE USED FOR THE CONDUCTOR SIZES FROM AWG 14 TO AWG 1. CONDUITS CONCEALED IN WALL AND CEILING U.O.N. THE DRAWING OR NOT. SIZE OF THE GROUND WIRE SHALL BE AS REQUIRED PER NEC * '. <br /> 1. ALL WIRING(EXCEPT POWER POLES)SHALL BE INSTALLED IN CODE APPROVED 2. MINIMUM CONDUIT SIZE •••. REN. 12-17 <br /> 2. THEY CAN BE USED FOR FEEDERS AND BRANCH CIRCUITS IN BOTH EXPOSED AND CONCEALED WORK,CABLES TRAYS, DRY SHALL BE 1/2". MINIMUM ACCEPTABLE CONDUITS ARE: 13. ALL RECEPTACLE CIRCUITS SHALL INCLUDE A GREEN GROUND WIRE WITH CONNECTOR TO EACH GROUND <br /> Annex E:Construction Types INFORMATIVE ANNEX E LOCATIONS, EMBEDDED IN PLASTER OR BRICK AND AIR VOIDS WHERE NOT EXPOSED TO EXCESSIVE MOISTURE AND DAMPNESS. A. GALVANIZED RIGID STEEL STUD. METAL STUD FRAMING, IF USED,SHALL BE CONNECTED TO THE SERVICE GROUNDING BUSSBAR. 9TF Ur CPI-�F��� <br /> 3. THEY MUST NOT BE INSTALLED IN LOCATIONS SUBJECT TO PHYSICAL DAMAGE, IN DAMP OR WET LOCATIONS, IN AIR VOIDS OF B. GALVANIZED STEEL EMT-NOT APPROVED ON ROOF <br /> MASONRY BLOCK TILE WALLS. C. LIQUID TIGHT STEEL FLEX-FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT. 14. THE TOTAL BRANCH POWER, LIGHTING CIRCUITS, CONDUITS,AND RACEWAY ROUTING HAVE NOT BEEN <br /> Informative Annex E es of Construction 4. MC CABLES ARE PERMITTED FOR FEEDER AND BRANCH CIRCUITS IN INDOOR AND OUTDOOR, EXPOSED OR CONCEALED, D. FLEXIBLE STEEL CONDUIT-FOR INDOOR FINAL CONNECTIONS TO MECHANICAL EQUIPMENT(NOT TO SHOWN ON THE PLANS. PROVIDE CONTINUOUS CONDUITS, RACEWAYS AND CIRCUIT CONDUCTORS AS <br /> DIRECTLY BURIED(IF IDENTIFIED FOR PURPOSE), IN A CABLE TRAY, IN A RACEWAY, EMBEDDED IN PLASTER OR BRICK. EXCEED 36"). REQUIRED BETWEEN DEVICES SHOWN (I.E. RECEPTACLES, LIGHTING FIXTURES, METERS, MECHANICAL <br /> 5. MC CABLES ARE PERMITTED TO BE USED IN WET LOCATIONS IF FOLLOWING CONDITIONS ARE MET. E. PVC CONDUIT ONLY UNDERGROUND. EQUIPMENT, PANELS, ETC.)WITH RESPECTIVE CIRCUIT NUMBERS SHOWN ON PANEL SCHEDULES. <br /> This informative annex is not a part of the requirements of this NFPA rated construction requires all interior partitions to be one- a.THE METALLIC COVERING IS IMPERVIOUS TO <br /> document but is included for informational purposes only. hour rated.Non-rated construction allows nonbearing interior MOISTURE. <br /> partitions to be of non-rated construction. The maximum WIRING DEVICES: 15. MAINTAIN CODE REQUIRED CLEARANCE IN FRONT OF ALL POWER PANELS, METERS,TRANSFORMERS,AND <br /> g permitted number of stories for multifamily dwellings and b.A LEAD SHEATH OR MOISTURE-IMPERVIOUS <br /> Table E.1 contains the fire resistance rating, in hours, for P Y Ss UNITS SHALL BE SPECIFICATION GRADE, EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS OTHER ELECTRICAL EQUIPMENT. MAINTAIN SEPARATION OF COMMUNICATION EQUIPMENT. <br /> Types I through V construction. The five different es of other structures is two for non-rated and four for one-hour JACKET IS PROVIDED UNDER THE METAL <br /> � g � rated. COVERING. (BROWN,WHITE, GREY, BEIGE OR IVORY)AS SELECTED BY THE ARCHITECT: CD <br /> construction can be summarized briefly as follows (see also 16. ALL NEW ELECTRICAL PANELS AND DISCONNECT SWITCHES SHALL BE MOUNTED AT+6'-6"AFF(AFG)TO TOP <br /> Table E.2): c.THE INSULATED CONDUCTORS UNDER THE <br /> Type IV is a single construction category that provides for 1. WIRING DEVICES LEVITON# HUBBELL# P&S# OF TRIM UNLESS OTHERWISE NOTED ON THE DRAWINGS. <br /> Type I is a fire-resistive construction e. All structural heavy timber construction.Both the structural framework and METALLIC COVERING ARE LISTED FOR USE IN <br /> YP nP SINGLE POLE SWITCH 1221 HBL 1221 20AC1 <br /> elements and most interior elements are required to be the exterior walls are required to be noncombustible except WET LOCATIONS AND ACORROSION-RESISTANT THREE WAY SWITCH HBL 1223 HBL 1223 20AC3 17. ALL NEW ELECTRICAL METERS AND MAJOR EQUIPMENT SHALL BE PROVIDED WITH ENAMELED PHENOLIC <br /> noncombustible.Interior,nonbearing partitions are permitted that wood members of certain minimum sizes are allowed.This JACKET IS PROVIDED OVER THE METALLIC �' <br /> to be 1 or 2 hour rated.For nearly all occupancy types,Type I construction type is seldom used for multifamily dwellings but, SHEATH. DUPLEX CONV.OUT.20A 5362 5362 5362 NAMEPLATE SECURED TO ENCLOSURE WITH STAINLESS STEEL SCREWS. PROVIDE PANEL DIRECTORIES. <br /> construction can be of unlimited hei ht. if used,would be permitted to be four stories high. DUPLEX GFI CONV. OUT. 15 AMP GF5252A Q -7) 0 <br /> g 6. MC CABLES MUST NOT BE INSTALLED IN LOCATIONS SUBJECT TO PHYSICAL DAMAGE AND EXPOSED TO DESTRUCTIVE TO 18. PROVIDE#4 NYLON PULL CORD IN ALL NEW CONDUITS INCLUDING CONDUITS WHERE WIRING IS BEING <br /> Type II construction has three categories: fire-resistive,one- Type V construction has two categories:one-hour rated and CORROSIVE CONDITIONS. DEVICE PLATES: INSTALLED. COORDINATE WORK WITH BRETT FULLINGTON AT GIACALONE(925)467-1740 REGARDING JOINT <br /> hour rated, and non-rated. The number of stories permitted non-rated. One-hour rated construction requires a minimum 7. EMT ARE PERMITTED TO BE USED FOR FEEDER AND BRANCH CIRCUITS FOR BOTH EXPOSED AND CONCEALED WORK IN IN N <br /> for multifamily dwellings varies from two for non-rated and of one-hour rated construction throughout the building.Non- 1. ALL DEVICE PLATES FOR INDOOR USE SHALL BE SMOOTH NYLON OR APPROVED EQUAL UNLESS OTHERWISE TRENCH LOCATIONS. W <br /> Y g CONCRETE, IN DIRECT CONTACT WITH THE EARTH OR IN AREAS SUBJECT TO SEVERE CORROSIVE INFLUENCES WHERE LO <br /> four for one-hour rated to 12 for fire-resistive construction. rated construction allows non-rated interior partitions with NOTED. ALL DEVICE PLATES FOR OUTDOOR USE SHALL BE RAISED METAL. <br /> INSTALLED IN ACCORDANCE WITH 358.10(8), IN DRY, DAMP AND WET LOCATIONS. <br /> 06 11-- <br /> certain restrictions.The maximum permitted number of stories 19. ALL NEW ELECTRICAL EQUIPMENT INSTALLED OUTDOORS AND OTHER WET LOCATIONS SHALL BE <br /> Type III construction has two categories:one-hour rated and for multifamily dwellings and other structures is two for non- 8. EMT ARE PERMITTED TO BE USED IN CORROSIVE ENVIRONMENT INCLUDING DAMP AND WET LOCATIONS IF FOLLOWING 2. VICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE 1/2"RAISED STEEL PLATES. WEATHERPROOF WEATHERPROOF, NEMA-3R AND SHALL BE PROVIDED WITH EPDXY PAINT FINISH OR TWO COATS ENAMEL, r Q <br /> non-rated. Both categories require the structural framework rated and three for one-hour rated. CONDITIONS ARE MET: COVERS TO BE SNAP TYPE COVERS. COLOR TO MATCH ADJACENT EXISTING SURFACES OR AS DIRECTED BY THE ARCHITECT. CD <br /> and exterior walls to be of noncombustible material.One-hour a. GALVANIZED STEEL AND STAINLESS STEEL EMT, ELBOWS,AND FITTINGS SHALL BE PERMITTED TO BE INSTALLED IN Ch LO <br /> M V <br /> CONCRETE, IN DIRECT CONTACT WITH THE EARTH,OR IN AREAS SUBJECT TO SEVERE CORROSIVE INFLUENCES WHERE 20. QUESTIONS DURING CONSTRUCTION SHALL BE DIRECTED TO KTGY ARCHITECTS AND THE ENGINEERS. <br /> Table E.1 Fire Resistance Ratings for Type I Through Type V Construction(hr) PROTECTED BY CORROSION PROTECTION AND APPROVED AS SUITABLE FOR THE CONDITION. 0 � Q <br /> b.ALUMINUM EMT SHALL BE PROVIDED WITH APPROVED SUPPLEMENTARY CORROSION PROTECTION WHERE ENCASED IN 21. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR DAMAGES TO ALL WALLS, FLOORS AND CEILINGS <br /> Type Type II Type III Type IV Type CONCRETE OR IN DIRECT CONTACT WITH THE EARTH. INCURRED DURING ELECTRICAL CONSTRUCTION. IF ANY DAMAGE OCCURS DURING ELECTRICAL O <br /> 442 332 222 111 000 211 200 21111 111 000 c.GALVANIZED STEEL AND STAINLESS STEEL EMT SHALL BE PERMITTED TO BE INSTALLED IN CINDER CONCRETE OR CINDER FILL PG&E SERVICE GUIDELINES CONSTRUCTION ELECTRICAL CONTRACTOR SHALL PATCH, REPAIR AND PAINT DAMAGING SURFACES TO W >= <br /> V J <br /> WHERE SUBJECT TO PERMANENT MOISTURE WHEN PROTECTED ON ALL SIDES BY A LAYER OF NON-CINDER CONCRETE AT MATCH ORIGINAL CONDITION. <br /> LMLM Exterior Bearing Walls LEAST 50 MM (2 IN.)THICK OR WHEN THE TUBING IS INSTALLED AT LEAST 450 MM(18 in.)under the fill. <br /> Supporting more than one floor, 4 3 2 1 0b 2 2 2 1 0b <br /> d.ALL SUPPORTS, BOLTS,STRAPS, SCREWS,AND SO FORTH SHALL BE OF CORROSION-RESISTANT MATERIALS OR PROTECTED O <br /> columns,or other bearing walls 1. FOR SERVICE LATERALS 75FT.OR GREATER IN LENGTH, CONTACT PG&E TO VERIFY SERVICE CONDUIT AND 22. SIZE OUTLET BOXES IN CONFORMITY WITH NEC FOR NUMBER AND GAUGE OF CONDUCTORS THEREIN, Z <br /> Supporting one floor only 4 3 2 1 0b 2 2 2 1 0b AGAINST CORROSION BY CORROSION-RESISTANT MATERIALS. <br /> Supportingaroofonly Y 4 3 1 1 Ob 2 2 2 1 Ob 9. PVC CONDUIT SHALL BE PERMITTED IN WALLS, FLOORS CEILINGS AND CINDER FILLS,AND LOCATIONS SUBJECT TO SEVERE TERMINATION REQUIREMENTS ADJUST CONDUITS AND MAIN SERVICE SIZE ACCORDINGLY PER UG-1 EXCEPT WHERE NOTED TO BE LARGER. MINIMUM BOX SIZE SHALL BE 4"SQUARE BY 1-1/2"DEEP. W ♦�^ Uj CD <br /> GREENBOOK DOCUMENT 063927,TABLE2. <br /> CORROSIVE INFLUENCES AND WHERE SUBJECT TO CHEMICALS FOR WHICH THE MATERIALS ARE SPECIFICALLY APPROVED. 10- <br /> Supporting <br /> W <br /> Interior Bearing Walls 23. COORDINATE ALL WORK WITH THE GENERAL CONTRACTOR AND OTHER TRADES, KEEP THE SITE IN A CLEAN V w <br /> Su ortin more than one floor, 4 3 2 1 0 1 0 2 1 0 10. PVC SHALL BE PERMITTED IN DRY,WET AND DAMP LOCATIONS, FOR UNDERGROUND DIRECT BURIAL OR ENCASED IN CONCRETE <br /> PP g 2. UG SERVICE TERMINATION ENCLOSURE, MAIN DISCONNECT AND MULTI-UNIT METERING ASSEMBLY SHALL BE AND SAFE CONDITION AT ALL TIMES,AND OBSERVE ALL CALOSHA AND SAFETY REGULATIONS. <br /> columns,or other bearing walls INSTALLATION. Q � 0 <br /> Supporting one floor only 3 2 2 1 0 1 0 1 1 0 11. THHW OR THWN INSULATION TO BE USED WITH PVC OR EMT CONDUITS. PER PG&E UG-1 SERVICES GREENBOOK DOCUMENT 058817. act <br /> Supporting roofs only 3 2 1 1 0 1 0 1 1 0 12. REFER TO SINGLE LINE DIAGRAMS TO FIND WETHER THE CONDUCTOR IS COPPER OR ALUMINIUM. 24. REFER TO SDG UTILITY PLANS FOR RECEPTACLES AND PROPOSED LIGHTING FIXTURES. 1 CO 0 <br /> Columns 13. NM(ROMEX)CABLES CAN BE USED FOR BOTH EXPOSED AND CONCEALED WORK IN NORMALLY DRY LOCATIONS. 3. CONSULT A PG&E COORDINATOR DURING THE INITIAL CONSTRUCTION OF THE PROJECT TO DETERMINE THE <br /> Supporting more than one floor, 4 3 2 1 0 1 0 H 1 0 METERING EQUIPMENT. 25. CONNECT ALL WALL MOUNTED LIGHTS AT GARAGES TO CENTRAL HOUSE PANEL WITH PC CONTROL. W <br /> PP g THEY CAN BE USED IN ONE AND TWO FAMILY DWELLINGS WITH ATTACHED GARAGES AND CAN BE USED IN MULTI-FAMILY Z V � <br /> Uj <br /> columns,or other bearing walls DWELLINGS WITH THE CONSTRUCTION TYPES OF iii, iv&v,CAN BE INSALLED OR FISHED IN AIR VOIDS IN MASONRY BLCK OR <br /> Supporting one floor only 3 2 2 1 0 1 0 H 1 0 4. THE WORKING SPACE MUST BE CLEAR AND UNOBSTRUCTED,AND SHALL BE AS PER PG&E GREENBOOK �/� <br /> Supporting roofs 3 2 1 1 0 1 0 H 1 0 TILE WALLS. 0 C <br /> PP g Y SECTION 5.4.3 �('� <br /> 14. NOT ALLOWED WHERE EXPOSED TO CORROSIVE FUMES OR VAPORS, EMBEDDED IN MASONRY CONCRETE,ADOBE, FILL OR +, <br /> Beams,Girders,Trusses,and Arches PLASTER,OR IN DAMP OR WET LOCATIONS. 5. A MINIMUM OF 24 INCHES OF COVER FOR SECONDARY(0-750V)ELECTRIC SERVICE,OR 36 INCHES MINIMUM 0 r <br /> Supporting more than one floor, 4 3 2 1 0 1 0 H 1 0 COVER FOR PRIMARY(OVER 750V)IS REQUIRED. COVER IS THE DISTANCE FROM THE OUTER SURFACE OF AN r <br /> 15. NM CABLES SHALL BE PROTECTED FROM PHYSICAL DAMAGE OR THROUGH FRAMING MEMBERS BY RMT, EMT SCH.80 PVC OR <br /> columns,or other bearing walls UNDERGROUND FACILITY TO THE TOP OF THE FINAL GRADE.THE ACTUAL TRENCH DEPTH WILL BE GREATER <br /> Supporting one floor only 2 2 2 1 0 1 0 H 1 0 OTHER APPROVED CONDUITS BY CEC ART 334. <br /> Supporting roofs only 2 2 1 1 0 1 0 H 1 0 TO ACCOMMODATE THE UNDERGROUND FACILITY. <br /> Floor/Ceiling Assemblies 2 2 2 1 0 1 0 H 1 06. CHOOSE THE LOCATION <br /> Roof/Ceiling Assemblies 2 1V2 1 1 0 1 0 H 1 0 PROJECT RELEATED NOTES9110100 <br /> m <br /> Interior Nonbearing Walls 0 0 0 0 0 0 0 0 0 0 � / <br /> Exterior Nonbearing Walls' Ob Ob Ob Ob Ob ob Ob Ob Ob Ob <br /> Source:Table 7.2.1.1 from NFPA 5000,Building Construction and Safety Code,2012 edition. <br /> 1. ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE MOST RECENTLY ADOPTED EDITION OF 0 <br /> H:Heavy timber members. <br /> N.E.C.,STATE OF CALIFORNIA TITLE 24, PART 3, INTERNET REQUIREMENTS AND ALL APPLICABLE CODES. <br /> 'See 7.3.2.1 in AIM 5000. <br /> 'See Section 7.3 in NFPA5000. 2. THE CONTRACTOR SHALL VISIT THE SITE AND SATISFY HIMSELF AS TO THE PROPOSED SYSTEM AND LIMITS <br /> °See 7.2.3.2.12,7.2.4.2.3,and 7.2.5.6.8 in NFPA5000. OF SUCH. THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS IN ORDER TO ACHIEVE INDICATED / <br /> RESULTS EVEN THOUGH ALL DETAILS ARE NOT SHOWN. <br /> 70-804 NATIONAL ELECTRICAL CODE 2017 Edition <br /> 3. PROVIDE ALL LABOR, MATERIALS,TOOLS, PLANT EQUIPMENT,AND/OR TRANSPORTATION AND PERFORM ALL REVISIONS <br /> SERVICE EQUIPMENT LOCATION OPERATIONS NECESSARY FOR ANYTHING REASONABLY INCIDENTAL TO PROPERLY EXECUTE AND COMPLETE <br /> ALL"ELECTRICAL WORK"WHETHER SPECIFICALLY MENTIONED OR NOT;ALL AS INDICATED,SPECIFIED Z� - - - <br /> HEREIN,AND/OR IMPLIED THEREBY,TO CARRY OUT THE APPARENT INTENT THEREOF. <br /> 1. SINGLE FAMILY DWELLINGS WILL NORMALLY HAVE THEIR SERVICES LOCATED ON A CORNER WHICH IS - - <br /> CONSTRUCTION TYPES AS PER CEC 2017 ANNEX E NEAREST TO THE COMPANY'S LINE. 4. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, LICENSES, ETC. REQUIRED TO <br /> CARRY ON AND COMPLETE THE WORK. <br /> 2. A SERVICE FROM OVERHEAD LINES,SHALL BE LOCATED AT THE CORNER NEAREST TO COMPANY POLE. <br /> 5. ALL ELECTRICAL MATERIALS SHALL BE NEW OR SUITABLE FOR RE-USE SUCH AS PANELS R-3 AND R-5 LISTED - - - <br /> 3. A SERVICE FROM UNDERGROUND LINES SHALL BE LOCATED AT THE CORNER NEAREST TO THE WITH THE UNDERWRITERS' LABORATORIES, INC.,SHALL MEET THEIR REQUIREMENTS AND SHALL BEAR <br /> LL <br /> TRANSFORMER INSTALLATION OR UNDERGROUND SERVICE ENCLOSURE. THEIR LABEL WHEREVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY / <br /> FURNISHED BY THAT AGENCY. <br /> 4. THE SERVICE SHALL NOT REQUIRE REQUIRE THE COMPANY'S LINE TO CROSS AN ADJACENT PROPERTY. a) <br /> 6. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZE AND LOCATIONS OF <br /> 5. A MAXIMUM OF SIX DISCONNECTS ARE PERMITTED TO BE INSTALLED AT THE SERVICE ENTRANCE.ALL THESE EQUIPMENT MIGHT BE SHOWN TO SCALE WHEREVER POSSIBLE, CONTRACTOR SHALL MAKE USE OF ALL DATA <br /> DISCONNECTS MUST BE GROUPED TOGETHER AT A SINGLE LOCATION. IN ALL CONTRACT DOCUMENTS AND IN MANUFACTURERS'LITERATURE AND VERIFY THIS INFORMATION AT A <br /> THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID U <br /> 6. SERVICE CONDUCTORS RUN ALONG THE EXTERIOR OF A BUILDING OR ARE ENCASED IN 2"OF CONCRETE INTERFERENCE WITH OTHER TRADES. CONTRACTOR SHALL NOTIFY GENERAL CONTRACTOR IMMEDIATELY Z� <br /> WITHIN THE BUILDING. OF ANY POTENTIAL OR CURRENT CONFLICTS AND SEEK A ACCEPTABLE RESOLUTION TO ANY SUCHE <br /> CONFLICTS. NO. Date Drn Remarks <br /> 7. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE TW FOR#8 OR SMALLER AND COPPER CONDUCTORS DRAWN: F.S. z <br /> TYPE THWN FOR#6 OR LARGER UNLESS OTHERWISE REQUIRED BY CODE. CHECKED: J.R. <br /> DATE: 09/17/2019 <br /> SCALE: AS NOTED <br /> JOB NO: 22003 <br /> SHEET TITLE N <br /> ELECTRICALCD <br /> N <br /> NOTES & <br /> DETAILS <br /> SHEET n <br /> If a Builder and/or Subcontractor deviates in anyway <br /> from any design produced by California Living & Energy <br /> without the expressed written consent of California Living \ <br /> & Energy then all warranties become null and void. For <br /> further clarification refer to clauses & warranties section EmOol0 <br /> of our bid proposal & contract section VI. 0 <br /> ALL PROJECT DRAWINGS, SPECIFICATIONS AND OTHER WORK PRODUCT PREPARED BY CALIFORNIA LIVING & ENERGY ARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF CLE WHETHER THE PROJECT IS COMPLETED OR NOT. ANY REVISIONS, CHANGES, ADAPTATIONS <br /> ETC. TO CLE's INSTRUMENTS OF SERVICE, ALSO KNOWN AS BUT NOT LIMITED TO DESIGN MUST BE APPROVED IN WRITING BY CLE. REUSE BY CLIENT OF ANY OF CLE's INSTRUMENTS OF SERVICE FOR ANY PROJECT OTHER THAN THE PROJECT THAT IS THE SUBJECT OF THIS AGREEMENT IS UNAUTHORIZED. <br />