My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHURCH
>
11
>
1600 - Food Program
>
PR0546490
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2021 8:56:06 AM
Creation date
3/11/2021 2:31:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546490
PE
1624
FACILITY_ID
FA0026353
FACILITY_NAME
RUBY'S BAKERY AND CAFE
STREET_NUMBER
11
Direction
S
STREET_NAME
CHURCH
STREET_TYPE
ST
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
11 S CHURCH ST STE B
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KEYNOTES <br /> LU <br /> 1. UG SERVICE TERMINATION ENCLOSURE, MAIN DISCONNECT FOR SINGLE FAMILY c ,00�, o <br /> DWELLINGS SHALL BE PER PG&E GREENBOOK DOCUMENT 058817. N6 <br /> 2. SERVICE LATERAL TRENCHING, CONDUIT AND BACKFILL SHALL BE PER PG&E GREENBOOK W 0.> E <br /> DOCUMENT 063927. L.L W @ <br /> 3. FOR SERVICE LATERALS 75 FT OR GREATER IN LENGTH, CONTACT PG&E TO VERIFY J LU o o N CU ci o o <br /> N <br /> CONDUIT AND TERMINATION REQUIREMENTS, ADJUST CONDUIT AND MAIN SERVICE SIZE <br /> ACCORDINGLY PER GREENBOOK DOCUMENT 063927. Q Z <br /> ca � <br /> Q w <br /> Z � <br /> 4. LOCATION OF THE METER PANEL COMBINATION.EQUIPMENT MAY BE INSTALLED AT 06 <br /> OPPOSITE END OF BUILDING AS REQUIRED, BASED ON TRANSFORMER LOCATION, REFER OLU Jw J <br /> TO SITE UTILITY PLAN. CD <br /> 5. REQUIRED WORKING SPACE CLEARANCES CEC 110.26: JLL 06 W E <br /> ' � 'E <br /> Q N o <br /> DEPTH -42in. U _ <br /> U — <br /> WIDTH - 30in. or WIDTH OF EQUIPMENT WHICHEVER IS GREATER LU C ° •� <br /> C6 � UJC� •O <br /> HEIGHT-61 ft. OR EQ. HEIGHT WHICHEVER IS GREATER Z o o <br /> 6. THE MAIN ELECTRICAL SERVICE SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE E UC M p o E o <br /> INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC °O <br /> INSTALLATION, LOCATED AT THE OPPOSITE END OF THE BUS BAR AS THE FEEDER O >_ oo� Cn v o <br /> CONDUCTORS, AND BE LABELED FOR FUTURE SOLAR ELECTRIC." z V J (N D �00 <br /> rn U <br /> 8. PROVIDE A WORKING SPACE CLEARANCE OF 36" INFRONT HVAC DISCONNECT AS PER 0 ~ Q N o E <br /> CEC110.26(A)(1)AND DISCONNECT SHALL BE LOCATED WITHIN SIGHT FROM AND READILY 003 <br /> ACCESSIBLE FROM THE AC UNIT, THE DISCONNECTS SHALL BE PERMITTED TO BE U Qj 2 o v) <br /> INSTALLED WITHIN THE UNIT AND DISCONNECTS AND DISCONNECTS SHALL NOT BE cn <br /> BOTTOM FED PANEL A NEMA 2/NEMA 3R LOCATED ON PANELS THAT ARE DESIGNED TO ALLOW ACCESS TO THE EQUIPMENT OR TO <br /> LU CD `° co E <br /> — ° a <br /> C/3 a) O ov) Q � <br /> MAIN BREAKER : 65KAIC 120/240V 1-PH 3-WIRE SURFACE MOUNTED OBSCURE THE EQUIPMENT NAMEPLATE AS PER CEC440.14. ZO U H Q3: <br /> LOADS wfl- co LOADS SINGLE LINE DIAGRAM NOTES U <br /> LU <br /> I_ U u) v DESCRIPTION A B w JY Q Y w J A B DESCRIPTION U Lh U � <br /> O w _j 2 O U = U 2 O w O 1. VERIFY WITH SERVICE PLANNER FOR AIC RATING AND ELECTRICAL INFOR BEFORE STAMP: <br /> Z Q Q G� Z ISSUING ANY BID. NOTIFY ENGINEER IMMEDIATELY IF MAJOR DISCREPANCIES OCCURS. S�� ARCy <br /> 1 1 AC UNIT 2500 30 1 A 1 2 40 4800 ELECTRIC TANKLESS WATER HEATER 1 1 S\N B s .•F�� <br /> 2500 23 B 4 2 4800 <br /> 1,6 1 KITCHEN +OFFICE+ RESTROOM LIGHTS(AFCI) 900 20 1 5 A 6 20 1 1200 DISH WASHER RECP.GFCI 1 1 GG! (Jw <br /> rizel <br /> 1,6 1 SERVICE+CUSTOMER AREA+ HALL LIGHTS(AFCI) 900 20 1 7 B 8 20 1 1000 COFFEE MAKER RECP. GFI 1 1 *•; C-2552 <br /> 1 HOOD RECP.GFI 1200 20 1 9 A 10 20 1 1200 FLOOR MIXER RECP.GFI 1 1 PANEL SCHEDULE NOTES. ••• •• <br /> •• R EN. 12-17•.• Q <br /> 1 OVEN RECP.GFCI 1200 20 1 11 B 12 20 1 800 WORK TOP REFIG. RECP.GFI 1 1 OF CPL�FQ��\ <br /> 1 RANGE/OVEN RECP.GFI 1200 20 1 13 A 14 20 1 800 LOWDRINKREFRIG. RECP_ GFI 1 1 1 . PROVIDE BREAKER SIZE AS PER MFG REQUIREMENTS <br /> 1 3 DOOR FREEZER RECP. GFI 1200 20 1 15 B 16 20 1 11200 COUNTERTOP MIXER RECP.GFI 1 1 2. REFER TO MECHANICAL DRAWINGS FOR DETAILED EQUIPMENT <br /> 1 3 DOOR REFIG.RECP.GFI 1200 20 1 17 A 18 20 1 1800 REF.MERCHANDISER DISP.RECP.GFI 1 1 3. BACKFEED TYPE BREAKER, SPACE RESERVED FOR FUTURE <br /> 1 PASS-TRU FREEZER RECP. GFI 900 20 1 19 B 20 20 1 2000 PROOF/ HOT CABINET RECP. GFI 1 1 SOLAR SYSTEM Z <br /> 1 ICE MACHINE RECP.GFI 900 20 1 21 A 22 SPARE 4. RESERVED SPACE FOR FUTURE EV CHARGER <br /> SPARE 23 B 24 20 1 180 BATHROOM RECP.RECP.GFCI 1 1 5. IS TYPICAL FOR THE PANEL SCHEDULE TO EXCEED PANEL �' <br /> SPARE 25 A 26 20 1440 SERVICE+CUSTOMER AREA RECP. GFI 8 1 SIZE, PANEL SIZE IS DECIDED PER NEC LOAD CALCULATION, C" <br /> SPARE 27 B 28 20 1440 KITCHEN RECP.GFI RECP. GFI 8 1 WHICH CONSIDERS DIFFERENT DEMAND FACTORS FOR �' L` <br /> SPARE 29 A 30 20 1440 HALL +OFFICERECP.GFI g 1 DIFFERENT TYPE OF LOADS. 0< <br /> - 6. A LISTED BRANCH FEEDER-TYPE AFCI INSTALLED AT THE 0 <br /> LOAD SUMMARY PANEL AMPS - 39150 240 N <br /> CONN. LOAD 38700 25% OF LCL = 450 VA = 163 AMPS ORIGIN OF THE BRANCH-CIRCUIT IN COMBINATION WITH A LO <br /> PHASE A 20580 25% OF LARGEST MOTOR LOAD = VA LISTED OUTLET BRANCH-CIRCUIT TYPE ARC-FAULT CIRCUIT 0116Q <br /> INTERRUPTER INSTALLED AT THE FIRST OUTLET BOX ON THE Q <br /> PHASE B 181201 TOTAL PANEL LOAD = 39150 VA PANEL SIZE REQUIRED : 400AMP BRANCH CIRCUIT. THE FIRST OUTLET BOX IN THE BRANCH N LO Z V <br /> SERVICE SIZE = 400 AMP, 120/240v 1-PHL <br /> CIRCUIT SHALL BE MARKED TO INDICATE THAT IT IS THE Z Q <br /> FIRST OUTLET OF THE CIRCUIT. Q <br /> PANELSCHEDULE <br /> w <br /> 1 QW07 <br /> SCALE: N.T.S L LU Z <br /> DC � w LLJ <br /> Dao Q � <br /> W <br /> z � <br /> = o � U <br /> A) Lr) <br /> r rn <br /> m <br /> m <br /> W <br /> Q <br /> 0 <br /> N <br /> 0 <br /> REVISIONS <br /> A - - - <br /> Q <br /> A - - - 0 <br /> 0 <br /> - - - <br /> 0 <br /> 0 - - - <br /> Z - - - °' <br /> 0 - - - <br /> A - - - <br /> No. Date Drn Remarks <br /> z <br /> DRAWN: F.S. <br /> CHECKED: J.R. <br /> DATE: 09/17/2019 <br /> SCALE: AS NOTED <br /> JOB NO: 22003 <br /> Ln <br /> SHEET TITLE N <br /> PANEL LOAD <br /> 0 <br /> N <br /> SCHEDULE \ <br /> SHEET <br /> If a Builder and/or Subcontractor deviates in anyway <br /> from any design produced by California Living & Energy <br /> without the expressed written consent of California Living \ <br /> & Energy then all warranties become null and void. ForT <br /> further clarification refer to clauses & warranties section Eml ol0 <br /> of our bid proposal & contract section A. <br /> ALL PROJECT DRAWINGS, SPECIFICATIONS AND OTHER WORK PRODUCT PREPARED BY CALIFORNIA LIVING & ENERGY ARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF CLE WHETHER THE PROJECT IS COMPLETED OR NOT. ANY REVISIONS, CHANGES, ADAPTATIONS <br /> ETC. TO CLE's INSTRUMENTS OF SERVICE, ALSO KNOWN AS BUT NOT LIMITED TO DESIGN MUST BE APPROVED IN WRITING BY CLE. REUSE BY CLIENT OF ANY OF CLE's INSTRUMENTS OF SERVICE FOR ANY PROJECT OTHER THAN THE PROJECT THAT IS THE SUBJECT OF THIS AGREEMENT IS UNAUTHORIZED. <br />
The URL can be used to link to this page
Your browser does not support the video tag.