My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHURCH
>
11
>
1600 - Food Program
>
PR0546490
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2021 8:56:06 AM
Creation date
3/11/2021 2:31:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546490
PE
1624
FACILITY_ID
FA0026353
FACILITY_NAME
RUBY'S BAKERY AND CAFE
STREET_NUMBER
11
Direction
S
STREET_NAME
CHURCH
STREET_TYPE
ST
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
11 S CHURCH ST STE B
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
50cfm MIN—\ <br /> ELECTRICAL NOTES ACCESSIBILITY NOTES : <br /> 1. MATERIALS AND INSTALLATION, AS A MINIMUM, ARE TO CONFORM WITH 1. FLOOR SURFACE OF TOILET ROOM SHALL BE SMOOTH, HARD AND NON- <br /> THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE ABSORBENT EXTENDING UPWARD A MINIMUM OF MIN. 4" ONTO WALLS <br /> 2. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER 2. WALLS ARE SMOOTH, HARD AND NON-ABSORBENT TO 48" IN HEIGHT, <br /> BALANCING OF ALL CIRCUITS AND ARE NOR ADVERSELY AFFECTED BY MOISTURE. O <br /> Drawn: <br /> 3. ALLOWABLE CLOSER PRESSURE SHALL BE 5 LBS. FOR INTERIOR DOORS, ZERTUCHE <br /> 3. LIGHT FIXTURES IN CONTACT WITH INSULATION TO BE U.L. LISTED FOR 5 LBS. FOR EXTERIOR DOORS. DRAFTING & DESIGN <br /> THERMAL BARRIER OR WITH 3" MINIMUM CLEARANCE HORACIO ZERTUCHE <br /> 4. DOOR HARDWARE TO BE OPERABLE WITH SINGLE EFFORT BY A LEVER \ (N)0 FICE <br /> / 1 1050 N.CARPENTER,SUITE-J <br /> 4. LIGHTS MUST NOT BE RECESSED IN FIRE RATED CEILINGS OF CORRIDOR LOCATED AT 37 A.F.F. MODESTO,CA 95351 CONSTRUCTION (209)507-6036 <br /> UNLESS BOXED WITH EQUIVALENT 5. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE <br /> Q (E)RESTROOM horacio@zertuchedrafting.com <br /> OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. / <br /> 5. THE DESIGNER ASSUMES NO LIABILITY OR RESPONSIBILITY TO ANYONE 6. NO THUMB LATCHES OR KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY I <br /> WHAT SO EVER AS A RESULT OF ANY INACCURACY OR CHANGE IN DOORS UNLESS OPERATED BY A SINGLE ACTION WITH A LEVER. <br /> INFORMATION GIVEN ON WHICH THESE PLANS ARE BASED. CONTRACTOR <br /> MUST VERIFY ALL EXISTING ITEMS BEFORE START THE WORK 12 DIA.MEDIUM IMPACT ABS PLASTIC SIGNS, I <br /> MATTE FINISH \ <br /> 6. LIGHT SWITCHES SHALL NOT BE LOCATED BEHIND ANY DOORS OR @ CENTER OF THE DOOR, AND <br /> EQUIPMENT fN @ A HEIGHT OF 60" FROM FINISH FLOOR. / <br /> 7. PROVIDE MULTI-LEVEL SWITCHING PER 2013 ENNERGY STANDARDS / U J <br /> 8. LABEL ALL CB AND PANEL BOARDS I n <br /> 9. ALL EMERGENCY, EXIT, AND LIGHT LUMINAIRES SHALL BE CONNECTED / / ` V <br /> AHEAD OF LOCAL SWITCHES. U.O.N m <br /> -b9- SINGLE SWITCH EXHAUST FAN 50cmf MIN. <br /> ® / 0 <br /> 10. ALL LIGHT FIXTURES SHALL HAVE A DISCONNECTING MEANS WITHIN �° <br /> 2 FOR SERVICE PERSONNEL DIMMER SWITCH a PHONE JACK <br /> GFCI PROTECTED MOTION SENSOR / M <br /> 11. ALL 125-VOLT AND 20 AMPERE RECEPTACLES LOCATED IN THE KITCHEN TO DUPLEX OUTLET RECEPTACLE +18" SWITCH +44" o l J <br /> BE GFCI PROTECTED <br /> r� <br /> 12. ALL 125-VOLT AND 20 AMPERE RECEPTACLES LOCATED WITHIN 6'OF THE &C CEILING DUPLEX RECEPTACLE I ° <br /> 48" FLOUR. LIGHT LI <br /> OUTSIDE EDGE OF A SINK ARE TO BE GFCI PROTECTED @-E EXISTING DUPLEX RECEPTACLE <br /> DBL DUPLEX RECEPTACLE o 0 o TRACT LIGHTS / <br /> z <br /> a. <br /> NOTES 220V DUPLEX RECEPTACLE ° <br /> RETURN AIR <br /> 1. ALL DOOR WIDTH TO BE 36 INCHES MIN. TO PROVIDE REQUIRED 32" [E-1] RECESSED CEILING LIGHT I I <br /> CLEAR WIDTH WHEN OPEN. <br /> 2. ALL RECEPTACLE OUTLETS ARE INSTALL AT NO LESS THAN 15" AND F(> WALL LIGHT AIR DIFFUSER <br /> NO GREATER THAN 48" ABOVE THE FLOOR. <br /> 3. ALL SWITCHES, CONTROLS, THERMOSTATS, ETC. ARE INSTALLED <br /> -0y <br /> CEILING LIGHT \ / <br /> MAX. 48" ABOVE THE FLOOR, MIN. 15" A.F.F. SINGLE CEILING12 CIRCUIT NO. <br /> 4. THERE WILL BE NO NEW EQUIPMENTS WEIGHT MORE THAN 400# AND DROPPED LIGHT <br /> NO NEW FIXTURES WEIGHT MORE THAN 20# MOUNTED OR SUSPENDED <br /> FROM ROOF, CEILING, OR WALLS. o EXIT SIGN WITH OUTLET \ c F�\ <br /> 5. THE SCOPE OF WORK WILL INCLUDE ANY NECESSARY ACCESSIBILITY <br /> IMPROVEMENTS PER CBC 11B SEC. 202 a (E) TENANT SIGN J-BOX (N)KITCHEN\ <br /> 6. SAFTY GLAZING MUST BE PROVIDED AT HAZARDOUS LOCATIONS PER Y I i " Z <br /> CBC 2406.4, INCLUDING, BUT NOT LIMITED TO GLAZING WITHIN 18" � ` ° <br /> OF A WALKING SURFACE, GLAZING IN DOORS, AND WINDOWS ADJACENT \ I <br /> TO DOORS HVAC UNIT i ° <br /> 7. A SEPARATE PERMIT FOR SIGN IS REQUIRED. LL_ I ---------- <br /> 8. ALL DEFERRED SUBMITTALS SHALL FIRST BE SUBMITTED TO THE YORK R-41OA-DEX AFFINITY SERIES, I I <br /> REGISTER DESIGN PROFESSIONAL WHO SHALL REVIEW AND FORWARD 5 TON OR EQUIPVALENT <br /> THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING Q <br /> THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED /DUCT SYSTEM � Q_ <br /> AND HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE <br /> � � <br /> DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT FLOW RATE : 698 FPM (E)400AMP PANEL W � Nt <br /> BE INSTALLED UNTIL DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN FLOW VOLUME 800 CFM = N <br /> W <br /> REVIEWED BY THE BUILDING OFFICIALS. DUCT LENGTH +100 FEET <br /> DEFERRED ITEMS : SIGN PERMIT W Lu 4 0) <br /> DUCT SIZE 14 W�, ROUND, FLEXIBLE = 4 <br /> 9. TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE A MIN. OF c () = O Q <br /> 3 FEET FROM ANY OPENNGS INTO THE BLDG.(I.E., BATH AND UTILITY \ W V = U <br /> FANS, ETC...) MUST BE 3 FEET AWAY FROM DOORS, WINDOWS OPENING, NOTE : SMOKE DETECTORS SHALL BE LOCATED IN THE SUPPLY AIR DUCT OF W U — <br /> SKYLIGHTS, OR ATTIC VENTS. THE SYSTEM AND CONNECTED SO THAT HVAC SUPPLY AIR IS SHUT DOWN \ O z p <br /> UPON DETECTION OF SMOKE IN THE THE SUPPLY AIR DUCT o <br /> \ _ <br /> \ U) z � � <br /> z < _ <br /> \ Q J <br /> L <br /> Z � W <br /> 0 <br /> Lu <br /> EH <br /> o °a <br /> \ 1 <br /> 41 <br /> Lu <br /> \ 1 LL <br /> \ , Q <br /> U <br /> 41 41 z C) <br /> \ Q <br /> (N)SERVICE AREA J Z <br /> Q � <br /> LU <br /> � U � <br /> Lu Q <br /> Lu m <br /> � _ m <br /> ILI Ll (N)CUSTOMER AREA <br /> w <br /> E <br /> I w z <br /> w <br /> / Z U <br /> W LL 1 <br /> < p <br /> �\ <br /> a <br /> Date: <br /> \ <br /> E E E <br /> \ / c Revisions: <br /> A109/01/2019 <br /> SWITCH TO <br /> CEILING OUTLET 0 10/04/2019 <br /> A311/21/2019 <br /> 1 ELECTRICAL PLAN <br /> Page No: <br />
The URL can be used to link to this page
Your browser does not support the video tag.