HVAC ROOFTOP EQUIPMENT SCHEDULE *OUTDOOR AIR CALCULATIONS KEYNOTES (#) <br /> w 6 � E <br /> FAN 2nd STAGE- HEATING ALL KEYNOTES MAY NOT BE APPLICABLE N o <br /> SELECTION COOLING CAPACITY CD <br /> CAPACITY ELECTRICAL N OO � <br /> MANUFACTURER 1. EXHAUST DUCT VENT THRU WALL (REFER TO N N M •- 0 a� <br /> TAG MECHANICAL VENTILATION W Ln .� <br /> No. & TON POWER OUTSIDE SHEET M0.1 DETAIL 1). f0 � T <br /> MODEL AIR WEIGHT LL <br /> EXHAUST 25% CONTROLS (LBS) REMARKS Area(SF) CFM/SF #People CFM/Person CFM 2. REFER TO PLUMBING PLANS FOR GAS LINE SIZES J W o oN 0 CU 0 o <br /> DRIVE (HP) U) c <br /> KIT TOTAL/ CFM AND ROUTING. z N X 2 �� Ld <br /> CFM ESP EWB1 AFUE INPUT BTU/HR OUTPUT BTU/HR (CFM) Z <br /> SENS Office 130 0.06 1 5 13 Q � <br /> MBH AMB MCA MOCP VOLT/PH FLA (6 Q co � <br /> Hallway 200 0.18 - - 36 3. REFER TO PLUMBING PLANS FOR CONDENSATEU_ >1 <br /> �tS <br /> PROGRAMMABLE 25%OA,ECONOMIZER, Customer 700 0.18 23 7.5 299 DRAIN ROUTING. OTHERWISE, INSTALL PER CPC Of W <br /> *RTU-1 LENNOX KGB092S4B**Y,G,J 7.5 3600 1.0 2 HP,KIT 2 85.4175.2 80% 130,000 104,000 900 42 50 208 13 83.1 1069 <br /> THERMOSTAT &BAROMETRIC RELIEF � c > <br /> Kitchen 757 0.7 - - 530 SECTION 814.0 & CMC SECTION 309.0. L.L � J w J <br /> *CONTRACTOR TO PROVIDE AND INSTALL AMERICAN LENNOX CURB PER MANUFACTURERS INSTRUCTIONS AND LOCAL CODE REQUIREMENTS,ECONOMIZER KIT,OUTDOOR AIR KIT,BAROMETRIC RELIEF,AND STANDARD THROW-AWAY FILTER KIT. Minimum OutdoorAir 877 J 06 <br /> � E > d .� <br /> 4. REFER TO ELECTRICAL PLANS FOR ELECTRICAL LJL <br /> 7.5-Ton RTU AH @ 25%OA 900 FEEDS, AND MANUFACTURERS INSTRUCTIONS FOR Q o <br /> ELECTRICAL CONNECTIONS AND CONTROLS. W _j o -0 <br /> AHRI DATA � 0 .E o 0 <br /> 5. REFER TO STRUCTURAL PLANS FOR STRUCTURAL = J Q `� > <br /> MARK AHRI CERTIFIED COOLING I HEATING O C M O O <br /> FRAMING AND ATTACHMENTS TO STRUCTURE, AND E c L _0 <br /> **SQUARE FOOTAGE BASED ON NET OCCUPIABLE SQ FOOTAGE MANUFACTURERS INSTRUCTIONS FOR PROPER U 0 ti o <br /> NO. REFERENCE NUMBER CAP.(MBH) EER IEER AFUE INSTALLATION. °O - <br /> 2 CO <br /> RTU-1 10609476 851104 11.0 12.7 80% <br /> 6. REFER TO HOOD, EXHAUST FAN, AND MAKE-UP AIR z a) p M rn o o <br /> UNIT MANUFACTURERS INSTRUCTIONS FOR V J = � \ c E <br /> PROPER INSTALLATION AND CONTROLS. ~ Q p C) � o <br /> NO 0 C) :L-- 0 <br /> 00 <br /> 7. INTERLOCK THE KITCHEN EXHAUST HOOD WITH Q Q a) o <br /> THE MAKE-UP AIR FAN. aD Q a� 0 <br /> 1 . ALL SUPPLY & RETURN TRUNK LINES IN AN UNCONDITIONED SPACE SHALL BE R6 INSULATED SHEET METAL. � U 3 L <br /> 2. ALL SUPPLY & RETURN BRANCH DUCTS IN AN UNCONDITIONED SPACE SHALL BE R6 INSULATED FLEX DUCT. 8. EXHAUST DU NT THRU RO F (REFER TO LJJ m <br /> 3. ALL DUCT DIMENSIONS ARE INTERNAL DIMENSIONS. T M . DETAIL Z U a) <br /> /q 9. KITCHEN HOOD EXHAUST DUCT ACCESS OR U <br /> CLEANING AND INSPECTION WILL BE FROM THE <br /> ROOFTOP WITH THE FAN IN THE OPEN POSITION <br /> (SEE SHEET M0.3 "FAN IN THE OPEN POSITION"). <br /> THERE IS NO DAMPER IN THE EXHAUST DUCT.11 1 STAMP. <br /> T <br /> Q\koFESSION <br /> F <br /> A. TERMINATION OF ENVIRONMENTAL AIR DUCT: =co �`Z`�NY 44/ 41 <br /> • VENT/EXHAUST DUCT SHALL TERMINATE NOT J M 39333 <br /> LESS THAN 3 FEET FROM A PROPERTY LINE <br /> AND 3 FEET FROM OPENINGS INTO THE <br /> BUILDING (2016 CMC SECTION 502.2.1). <br /> • VENT/EXHAUST DUCT TO ROOF CAP SHALL BE �,9T FOHAN\OP���Q' <br /> ROUTED PER 2016 RESIDENTIAL COMPLIANCE FOFCAO <br /> MANUAL SE 110.10 & 201 CMC SECTION <br /> .1 <br /> 0000 <br /> /qle <br /> • TYPE I HOOD TERMINATES ABOVE THE OF, <br /> AT A MINIMUM OF 10 FEET FROM ADJACENT <br /> BUILDINGS, PROPERTY LINES, AIR INTAKES, OR <br /> OTHER OPENINGS INTO THE BUILDING; AND A <br /> MINIMUM OF 5 FEET FROM COMBUSTIBLE <br /> CONSTRUCTION. <br /> B. OSE CTW WI <br /> CONDITIONED SPA SHALL BE UNINSULATED <br /> SPIRAL SHEET METAL. <br /> C. REFER TO PLUMBING PLANS FOR RTU <br /> CONDENSATE DRAIN ROUTING. OTHERWISE, <br /> INSTALL PER CPC SECTION 814.0 & CMC SECTION <br /> 309.0. <br /> O >, <br /> Q) <br /> N � <br /> L m <br /> 4 <br /> Vco a <br /> Uj ._ <br /> r � � <br /> � J � <br /> O � m <br /> RRIT \/ � \ <br /> 0000Ii <br /> U <br /> r F i <br /> J O <br /> m � \ <br /> C.) <br /> 06 _j <br /> >V, Crj <br /> 0U <br /> O <br /> O <br /> W <br /> FEW <br /> LLMO <br /> O <br /> O <br /> O <br /> REVISIONS 10' <br /> 900 cfm OA DA 11/21/19 AA PC Comments <br /> E <br /> \ - -(iX2 3 5 A _ _ _ 0 <br /> O <br /> RTU MA <br /> 1 1 6 OO <br /> A <br /> co <br /> \ - - - <br /> O <br /> 07 <br /> 7.5-Tons <br /> /1 <br /> 16'- 10" 111,11,11, Z� - - - <br /> U <br /> 1O, No. Date Drn Remarks z <br /> DRAWN: A. Amadio <br /> CHECKED: HT 'j_ <br /> A DATE: 11/25/2019 <br /> SCALE: AS NOTED <br /> 6 7 8 EF KITCHEN HOOD EXHAUST IS AT LEAST 1 O'AWAY FROM ANY OUTDOOR AIR INTAKE, J 0 B N 0: 22471 <br /> 1 OPERABLE OPENING, AND ADJACENT BUILDING OR PROPERTY LINE. <br /> SHEET TITLE <br /> MECHANICALCD <br /> N <br /> ROOFTOP <br /> MECHANICAL ROOFTOP PLAN PLAN <br /> A <br /> SCALE: 1/4"= 1'-0" <br /> SHEET 0 <br /> m <br /> If a Builder and/or Subcontractor deviates in anyway E <br /> from any design produced by California Living & Energy <br /> without the expressed written consent of California Living \ <br /> & Energy then all warranties become null and void. For Q) <br /> further clarification refer to clauses & warranties section 11 <br /> of our bid proposal & contract section VI. 0 <br /> ALL PROJECT DRAWINGS, SPECIFICATIONS AND OTHER WORK PRODUCT PREPARED BY CALIFORNIA LIVING & ENERGY ARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF CLE WHETHER THE PROJECT IS COMPLETED OR NOT. ANY REVISIONS, CHANGES, ADAPTATIONS <br /> ETC. TO CL&E's INSTRUMENTS OF SERVICE, ALSO KNOWN AS BUT NOT LIMITED TO DESIGN MUST BE APPROVED IN WRITING BY CLE. REUSE BY CLIENT OF ANY OF CL&E's INSTRUMENTS OF SERVICE FOR ANY PROJECT OTHER THAN THE PROJECT THAT IS THE SUBJECT OF THIS AGREEMENT IS UNAUTHORIZED. <br />