Laserfiche WebLink
E-0.1ELECTRICALNOTES &DETAILS1050 N, CARPENTER RD. SUITE - J <br />MODESTO, CA 95351 <br />11 S. CHURCH ST. LODI, CA 95240------------------------------------F.S.J.R.09/17/2019AS NOTED22003REVISIONSNo.RemarksDRAWN:CHECKED:DATE:SCALE:JOB NO:DateSTAMP:SHEET TITLEToll Free: 800-498-4110 <br />Ceres, CA 209-538-2879 Fax: 209-538-2885 <br />www.califliving.comDrnSHEETREVISIONSNo.RemarksDRAWN:CHECKED:DATE:SCALE:JOB NO:DateSTAMP:SHEET TITLEToll Free: 800-498-4110 <br />Ceres, CA 209-538-2879 Fax: 209-538-2885 <br />www.califliving.comDrnSHEETC-2552James W. B. ShadeELECTRICAL GENERAL NOTES1.CONTRACTOR SHALL READ THE SPECIFICATIONS AND COMPLY WITH ALL REQUIREMENTS. THESE GENERALNOTES ARE INTENDED TO ASSIST THE CONTRACTOR DURING EXECUTION OF THE WORK. HOWEVER THEYDO NOT COVER ALL OF THE SPECIFICATION REQUIREMENTS.2.THE DRAWINGS INDICATE THE PANEL BOARDS AND CIRCUIT NUMBER FOR EACH OUTLET, ELECTRICALEQUIPMENT, ETC. THE EXACT LAYOUT AND CONFIGURATION OF THE BRUNCH CIRCUITS IS LEFT TO THECONTRACTOR WITHIN THE REQUIREMENTS ESTABLISHED HEREIN.3.LIGHTING BRANCH CIRCUITS SHALL NOT BE COMBINED WITH RECEPTACLES OR CONDUITS INTO MULTI-WIREBRUNCH CIRCUIT UNLESS SO INDICATED ON THE DRAWINGS.4.ALL CONDUITS PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS OR CEILINGS SHALL BE MADE WITHU.L. LISTED AND APPROVED MATERIALS AND METHODS AND SHALL COMPLY WITH 2016 CBC REQUIREMENTSAND LOCAL ORDINANCE PER THE RECENTLY ADOPTED NEC.5.ALL CONDUITS PENETRATING THROUGH THE EXTERIOR WALLS AND ROOFS SHALL ALL BE SEALEDWEATHER-TIGHT WITH U.L. APPROVED MATERIALS AND METHODS IN ACCORDANCE WITH CITY OF FREMONTAND U.B.C./C.B.C. STANDARDS.6.ALL ELECTRICAL WORK SHALL CONFIRM WITH LOCAL CODES, CEC, O.S.H.A. AND THE LATEST NECSPECIFICATIONS. POWER WORK TO COMPLY WITH PG&E REQUIREMENTS.7.CONTRACTOR SHALL FURNISH & INSTALL ALL ELECTRICAL EQUIPMENT, WIRES, CONDUITS, CONNECTIONS,OUTLETS, ETC. NECESSARY TO ACHIEVE A COMPLETE ELECTRICAL INSTALLATION. WHERE ELECTRICALDEVICES ARE REQUIRED BY CODE BUT NOT SHOWN, IT SHALL BE FURNISHED AND INSTALLED BY THECONTRACTOR AS THOUGH FULLY SHOWN AND SPECIFIED.8.ALL NEW ELECTRICAL EQUIPMENT SHALL BE SECURELY FASTENED TO STRUCTURE (S) TO MEET SEISMICREQUIREMENTS FOR THE BAY AREA LOCATION.9.ALL WORK SHALL BE INSTALLED IN NEAT, SAFE AND WORKMANLIKE MANNER.10.CONTRACTOR SHALL COORDINATE WORK WITH ALL TRADES TO AVOID CONFLICTS AND/OR DELAYS.11.ALL LIGHTING SWITCHES, SHALL BE INSTALLED MAXIMUM AT 48" ABOVE FINISHED FLOOR TO CENTERLINE.ALL RECEPTACLES OUTLETS SHALL BE INSTALLED AT LEAST 16" ABOVE FINISHED FLOOR TO CENTERLINE.12.CONTRACTOR SHALL PROVIDE A GROUND WIRE IN EACH CONDUIT WHETHER A GROUND WIRE IS SHOWN ONTHE DRAWING OR NOT. SIZE OF THE GROUND WIRE SHALL BE AS REQUIRED PER NEC13. ALL RECEPTACLE CIRCUITS SHALL INCLUDE A GREEN GROUND WIRE WITH CONNECTOR TO EACH GROUNDSTUD. METAL STUD FRAMING, IF USED, SHALL BE CONNECTED TO THE SERVICE GROUNDING BUSSBAR.14.THE TOTAL BRANCH POWER, LIGHTING CIRCUITS, CONDUITS, AND RACEWAY ROUTING HAVE NOT BEENSHOWN ON THE PLANS. PROVIDE CONTINUOUS CONDUITS, RACEWAYS AND CIRCUIT CONDUCTORS ASREQUIRED BETWEEN DEVICES SHOWN (I.E. RECEPTACLES, LIGHTING FIXTURES, METERS, MECHANICALEQUIPMENT, PANELS, ETC.) WITH RESPECTIVE CIRCUIT NUMBERS SHOWN ON PANEL SCHEDULES.15.MAINTAIN CODE REQUIRED CLEARANCE IN FRONT OF ALL POWER PANELS, METERS, TRANSFORMERS, ANDOTHER ELECTRICAL EQUIPMENT. MAINTAIN SEPARATION OF COMMUNICATION EQUIPMENT.16.ALL NEW ELECTRICAL PANELS AND DISCONNECT SWITCHES SHALL BE MOUNTED AT +6'-6" AFF (AFG) TO TOPOF TRIM UNLESS OTHERWISE NOTED ON THE DRAWINGS.17.ALL NEW ELECTRICAL METERS AND MAJOR EQUIPMENT SHALL BE PROVIDED WITH ENAMELED PHENOLICNAMEPLATE SECURED TO ENCLOSURE WITH STAINLESS STEEL SCREWS. PROVIDE PANEL DIRECTORIES.18.PROVIDE #4 NYLON PULL CORD IN ALL NEW CONDUITS INCLUDING CONDUITS WHERE WIRING IS BEINGINSTALLED. COORDINATE WORK WITH BRETT FULLINGTON AT GIACALONE (925) 467-1740 REGARDING JOINTTRENCH LOCATIONS.19.ALL NEW ELECTRICAL EQUIPMENT INSTALLED OUTDOORS AND OTHER WET LOCATIONS SHALL BEWEATHERPROOF, NEMA-3R AND SHALL BE PROVIDED WITH EPOXY PAINT FINISH OR TWO COATS ENAMEL,COLOR TO MATCH ADJACENT EXISTING SURFACES OR AS DIRECTED BY THE ARCHITECT.20.QUESTIONS DURING CONSTRUCTION SHALL BE DIRECTED TO KTGY ARCHITECTS AND THE ENGINEERS.21.CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR DAMAGES TO ALL WALLS, FLOORS AND CEILINGSINCURRED DURING ELECTRICAL CONSTRUCTION. IF ANY DAMAGE OCCURS DURING ELECTRICALCONSTRUCTION ELECTRICAL CONTRACTOR SHALL PATCH, REPAIR AND PAINT DAMAGING SURFACES TOMATCH ORIGINAL CONDITION.22.SIZE OUTLET BOXES IN CONFORMITY WITH NEC FOR NUMBER AND GAUGE OF CONDUCTORS THEREIN,EXCEPT WHERE NOTED TO BE LARGER. MINIMUM BOX SIZE SHALL BE 4" SQUARE BY 1-1/2" DEEP.23.COORDINATE ALL WORK WITH THE GENERAL CONTRACTOR AND OTHER TRADES, KEEP THE SITE IN A CLEANAND SAFE CONDITION AT ALL TIMES, AND OBSERVE ALL CALOSHA AND SAFETY REGULATIONS.24.REFER TO SDG UTILITY PLANS FOR RECEPTACLES AND PROPOSED LIGHTING FIXTURES.25.CONNECT ALL WALL MOUNTED LIGHTS AT GARAGES TO CENTRAL HOUSE PANEL WITH PC CONTROL.1.ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE MOST RECENTLY ADOPTED EDITION OFN.E.C., STATE OF CALIFORNIA TITLE 24, PART 3, INTERNET REQUIREMENTS AND ALL APPLICABLE CODES.2.THE CONTRACTOR SHALL VISIT THE SITE AND SATISFY HIMSELF AS TO THE PROPOSED SYSTEM AND LIMITSOF SUCH. THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS IN ORDER TO ACHIEVE INDICATEDRESULTS EVEN THOUGH ALL DETAILS ARE NOT SHOWN.3.PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, AND/OR TRANSPORTATION AND PERFORM ALLOPERATIONS NECESSARY FOR ANYTHING REASONABLY INCIDENTAL TO PROPERLY EXECUTE AND COMPLETEALL "ELECTRICAL WORK" WHETHER SPECIFICALLY MENTIONED OR NOT; ALL AS INDICATED, SPECIFIEDHEREIN, AND/OR IMPLIED THEREBY, TO CARRY OUT THE APPARENT INTENT THEREOF.4.ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, LICENSES, ETC. REQUIRED TOCARRY ON AND COMPLETE THE WORK.5. ALL ELECTRICAL MATERIALS SHALL BE NEW OR SUITABLE FOR RE-USE SUCH AS PANELS R-3 AND R-5 LISTEDWITH THE UNDERWRITERS' LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BEARTHEIR LABEL WHEREVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLYFURNISHED BY THAT AGENCY.6.ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZE AND LOCATIONS OFEQUIPMENT MIGHT BE SHOWN TO SCALE WHEREVER POSSIBLE, CONTRACTOR SHALL MAKE USE OF ALL DATAIN ALL CONTRACT DOCUMENTS AND IN MANUFACTURERS' LITERATURE AND VERIFY THIS INFORMATION ATTHE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT AND INSTALLING HIS WORK TO AVOIDINTERFERENCE WITH OTHER TRADES. CONTRACTOR SHALL NOTIFY GENERAL CONTRACTOR IMMEDIATELYOF ANY POTENTIAL OR CURRENT CONFLICTS AND SEEK A ACCEPTABLE RESOLUTION TO ANY SUCHCONFLICTS.7.CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE TW FOR #8 OR SMALLER AND COPPER CONDUCTORSTYPE THWN FOR #6 OR LARGER UNLESS OTHERWISE REQUIRED BY CODE.PROJECT RELEATED NOTESSUPPORTS:1.FURNISH ALL NECESSARY FOUNDATIONS, PADS, SUPPORTS, BACKING, ETC., FOR ALL ELECTRICALENCLOSURES, CONDUITS AND EQUIPMENT, OR COORDINATE W/G.C.2.ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, TO METAL WITH MACHINESCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS AND MACHINE SCREWS OR BOLTS.GROUNDING:1.GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND SPECIFICALLY INCLUDINGSWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC.PANELBOARDS:1.ALL UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL SCHEDULE, WITH THENUMBER AND SIZE OF BREAKERS AS INDICATED ON THE PANEL SCHEDULE. SINGLE POLE, TWO POLE, ANDTHREE POLE BREAKERS SHALL BE BOLT-ON TYPE. MULTIPLE POLE BREAKERS SHALL HAVE COMMONINTERNAL TRIP CONNECTION. SINGLE POLE BREAKERS SHALL NOT BE TIED AT HANDLES TO FORM MULTIPLEPOLE BREAKERS. THE PANEL DOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE KEYED ALIKEAND HAVE PRINTED DIRECTORIES INDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVED BY EACHBREAKER. PANELS SHALL HAVE COPPER BUSSING.TESTING:1.THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND IMPROPER GROUNDS.TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY FIXTURES OREQUIPMENT ARE CONNECTED AND WHETHER SUCH TESTS INDICATE FAULTY INSULATION OR OTHERDEFECTS, THEY SHALL BE LOCATED, REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. ROTATIONOF ALL MOTORS SHALL BE CHECKED AND CORRECTED, IF NECESSARY, AFTER FINAL CONNECTIONS AREMADE.2.DEMONSTRATE TO THE OWNER AND THE ENGINEER, THAT THE ENTIRE INSTALLATION IS COMPLETE, INPROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN PROPERLY AND FULLY EXECUTED.PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS.NAMEPLATES & IDENTIFICATION:INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC. NAMEPLATES SHALL BESECURELY FASTENED TO THE EQUIPMENT WITH #4 PHILLIPS ROUND HEAD CADMIUM PLATED SELF-TAPPINGSCREWS, BRASS BOLT, OR WITH A PLASTIC RESIN ADHESIVE GLUE, GOODYEAR "PLIEBOND" OR EQUAL.WIRING METHODS:CONDUITS CONCEALED IN WALL AND CEILING U.O.N.1.ALL WIRING (EXCEPT POWER POLES) SHALL BE INSTALLED IN CODE APPROVED 2. MINIMUM CONDUIT SIZESHALL BE 1/2". MINIMUM ACCEPTABLE CONDUITS ARE:A.GALVANIZED RIGID STEELB.GALVANIZED STEEL EMT - NOT APPROVED ON ROOFC.LIQUID TIGHT STEEL FLEX - FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT.D.FLEXIBLE STEEL CONDUIT - FOR INDOOR FINAL CONNECTIONS TO MECHANICAL EQUIPMENT (NOT TOEXCEED 36").E.PVC CONDUIT ONLY UNDERGROUND.WIRING DEVICES:UNITS SHALL BE SPECIFICATION GRADE, EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS(BROWN, WHITE, GREY, BEIGE OR IVORY) AS SELECTED BY THE ARCHITECT:1.WIRING DEVICESLEVITON #HUBBELL #P & S #SINGLE POLE SWITCH1221HBL 122120AC1THREE WAY SWITCH HBL1223HBL 122320AC3DUPLEX CONV. OUT. 20A536253625362DUPLEX GFI CONV. OUT. 15 AMPGF5252ADEVICE PLATES:1.ALL DEVICE PLATES FOR INDOOR USE SHALL BE SMOOTH NYLON OR APPROVED EQUAL UNLESS OTHERWISENOTED. ALL DEVICE PLATES FOR OUTDOOR USE SHALL BE RAISED METAL.2.VICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE 1/2" RAISED STEEL PLATES. WEATHERPROOFCOVERS TO BE SNAP TYPE COVERS.ELECTRICAL SPECIFICATIONS1.FOR SERVICE LATERALS 75FT. OR GREATER IN LENGTH, CONTACT PG&E TO VERIFY SERVICE CONDUIT ANDTERMINATION REQUIREMENTS ADJUST CONDUITS AND MAIN SERVICE SIZE ACCORDINGLY PER UG-1GREENBOOK DOCUMENT 063927 , TABLE2.2.UG SERVICE TERMINATION ENCLOSURE, MAIN DISCONNECT AND MULTI-UNIT METERING ASSEMBLY SHALL BEPER PG&E UG-1 SERVICES GREENBOOK DOCUMENT 058817.3.CONSULT A PG&E COORDINATOR DURING THE INITIAL CONSTRUCTION OF THE PROJECT TO DETERMINE THEMETERING EQUIPMENT.4.THE WORKING SPACE MUST BE CLEAR AND UNOBSTRUCTED , AND SHALL BE AS PER PG&E GREENBOOKSECTION 5.4.35.A MINIMUM OF 24 INCHES OF COVER FOR SECONDARY (0 - 750V) ELECTRIC SERVICE, OR 36 INCHES MINIMUMCOVER FOR PRIMARY(OVER 750V) IS REQUIRED. COVER IS THE DISTANCE FROM THE OUTER SURFACE OF ANUNDERGROUND FACILITY TO THE TOP OF THE FINAL GRADE. THE ACTUAL TRENCH DEPTH WILL BE GREATERTO ACCOMMODATE THE UNDERGROUND FACILITY.6.CHOOSE THE LOCATIONPG&E SERVICE GUIDELINES1.SINGLE FAMILY DWELLINGS WILL NORMALLY HAVE THEIR SERVICES LOCATED ON A CORNER WHICH ISNEAREST TO THE COMPANY'S LINE.2.A SERVICE FROM OVERHEAD LINES, SHALL BE LOCATED AT THE CORNER NEAREST TO COMPANY POLE.3.A SERVICE FROM UNDERGROUND LINES SHALL BE LOCATED AT THE CORNER NEAREST TO THETRANSFORMER INSTALLATION OR UNDERGROUND SERVICE ENCLOSURE.4.THE SERVICE SHALL NOT REQUIRE REQUIRE THE COMPANY'S LINE TO CROSS AN ADJACENT PROPERTY.5.A MAXIMUM OF SIX DISCONNECTS ARE PERMITTED TO BE INSTALLED AT THE SERVICE ENTRANCE. ALL THESEDISCONNECTS MUST BE GROUPED TOGETHER AT A SINGLE LOCATION.6.SERVICE CONDUCTORS RUN ALONG THE EXTERIOR OF A BUILDING OR ARE ENCASED IN 2" OF CONCRETEWITHIN THE BUILDING.SERVICE EQUIPMENT LOCATIONWIRING METHODS CEC ART. 300NOTES:1.AC CABLES CAN BE USED FOR THE CONDUCTOR SIZES FROM AWG 14 TO AWG 1.2.THEY CAN BE USED FOR FEEDERS AND BRANCH CIRCUITS IN BOTH EXPOSED AND CONCEALED WORK , CABLES TRAYS, DRYLOCATIONS, EMBEDDED IN PLASTER OR BRICK AND AIR VOIDS WHERE NOT EXPOSED TO EXCESSIVE MOISTURE AND DAMPNESS.3.THEY MUST NOT BE INSTALLED IN LOCATIONS SUBJECT TO PHYSICAL DAMAGE, IN DAMP OR WET LOCATIONS, IN AIR VOIDS OFMASONRY BLOCK TILE WALLS.4.MC CABLES ARE PERMITTED FOR FEEDER AND BRANCH CIRCUITS IN INDOOR AND OUTDOOR, EXPOSED OR CONCEALED,DIRECTLY BURIED(IF IDENTIFIED FOR PURPOSE), IN A CABLE TRAY, IN A RACEWAY, EMBEDDED IN PLASTER OR BRICK.5.MC CABLES ARE PERMITTED TO BE USED IN WET LOCATIONS IF FOLLOWING CONDITIONS ARE MET.a. THE METALLIC COVERING IS IMPERVIOUS TO MOISTURE.b. A LEAD SHEATH OR MOISTURE-IMPERVIOUS JACKET IS PROVIDED UNDER THE METAL COVERING.c. THE INSULATED CONDUCTORS UNDER THE METALLIC COVERING ARE LISTED FOR USE IN WET LOCATIONS AND A CORROSION-RESISTANT JACKET IS PROVIDED OVER THE METALLIC SHEATH.6.MC CABLES MUST NOT BE INSTALLED IN LOCATIONS SUBJECT TO PHYSICAL DAMAGE AND EXPOSED TO DESTRUCTIVE TOCORROSIVE CONDITIONS.7.EMT ARE PERMITTED TO BE USED FOR FEEDER AND BRANCH CIRCUITS FOR BOTH EXPOSED AND CONCEALED WORK IN INCONCRETE, IN DIRECT CONTACT WITH THE EARTH OR IN AREAS SUBJECT TO SEVERE CORROSIVE INFLUENCES WHEREINSTALLED IN ACCORDANCE WITH 358.10(B), IN DRY, DAMP AND WET LOCATIONS.8.EMT ARE PERMITTED TO BE USED IN CORROSIVE ENVIRONMENT INCLUDING DAMP AND WET LOCATIONS IF FOLLOWINGCONDITIONS ARE MET:a. GALVANIZED STEEL AND STAINLESS STEEL EMT, ELBOWS, AND FITTINGS SHALL BE PERMITTED TO BE INSTALLED INCONCRETE, IN DIRECT CONTACT WITH THE EARTH, OR IN AREAS SUBJECT TO SEVERE CORROSIVE INFLUENCES WHEREPROTECTED BY CORROSION PROTECTION AND APPROVED AS SUITABLE FOR THE CONDITION.b. ALUMINUM EMT SHALL BE PROVIDED WITH APPROVED SUPPLEMENTARY CORROSION PROTECTION WHERE ENCASED INCONCRETE OR IN DIRECT CONTACT WITH THE EARTH.c. GALVANIZED STEEL AND STAINLESS STEEL EMT SHALL BE PERMITTED TO BE INSTALLED IN CINDER CONCRETE OR CINDER FILLWHERE SUBJECT TO PERMANENT MOISTURE WHEN PROTECTED ON ALL SIDES BY A LAYER OF NON-CINDER CONCRETE ATLEAST 50 MM (2 IN.) THICK OR WHEN THE TUBING IS INSTALLED AT LEAST 450 MM (18 in.) under the fill.d. ALL SUPPORTS, BOLTS, STRAPS, SCREWS, AND SO FORTH SHALL BE OF CORROSION-RESISTANT MATERIALS OR PROTECTEDAGAINST CORROSION BY CORROSION-RESISTANT MATERIALS.9.PVC CONDUIT SHALL BE PERMITTED IN WALLS, FLOORS CEILINGS AND CINDER FILLS, AND LOCATIONS SUBJECT TO SEVERECORROSIVE INFLUENCES AND WHERE SUBJECT TO CHEMICALS FOR WHICH THE MATERIALS ARE SPECIFICALLY APPROVED.10.PVC SHALL BE PERMITTED IN DRY, WET AND DAMP LOCATIONS, FOR UNDERGROUND DIRECT BURIAL OR ENCASED IN CONCRETEINSTALLATION.11.THHW OR THWN INSULATION TO BE USED WITH PVC OR EMT CONDUITS.12.REFER TO SINGLE LINE DIAGRAMS TO FIND WETHER THE CONDUCTOR IS COPPER OR ALUMINIUM.13.NM(ROMEX) CABLES CAN BE USED FOR BOTH EXPOSED AND CONCEALED WORK IN NORMALLY DRY LOCATIONS. THEY CAN BE USED IN ONE AND TWO FAMILY DWELLINGS WITH ATTACHED GARAGES AND CAN BE USED IN MULTI-FAMILY DWELLINGS WITH THE CONSTRUCTION TYPES OF iii, iv & v, CAN BE INSALLED OR FISHED IN AIR VOIDS IN MASONRY BLCK OR TILE WALLS.14.NOT ALLOWED WHERE EXPOSED TO CORROSIVE FUMES OR VAPORS, EMBEDDED IN MASONRY CONCRETE, ADOBE, FILL ORPLASTER, OR IN DAMP OR WET LOCATIONS.15.NM CABLES SHALL BE PROTECTED FROM PHYSICAL DAMAGE OR THROUGH FRAMING MEMBERS BY RMT, EMT SCH. 80 PVC OROTHER APPROVED CONDUITS BY CEC ART 334.CONSTRUCTION TYPES AS PER CEC 2017 ANNEX E PANEL CLEARANCE