My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
2224
>
2300 - Underground Storage Tank Program
>
PR0232555
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 9:35:25 AM
Creation date
3/16/2021 7:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0232555
PE
2361
FACILITY_ID
FA0003679
FACILITY_NAME
CALIFORNIA STOP*
STREET_NUMBER
2224
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16313007
CURRENT_STATUS
01
SITE_LOCATION
2224 MANTHEY RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Spill Gontainer Testing Report Form <br />Test Method Developed by n Manufacturer n lndustry Standard n Professional Engineer <br />Test Type n Pressure n Vacuum X Hydrostatic <br />Tank lD 87 91 DIESEL <br />Spill Container Manufacturer:OPW OPW OPW <br />Method of Cathodic Protection X Nonmetallic <br />n Other <br />X Nonmetallic <br />n Other <br />X Nonmetallic <br />tr Other <br />tr Nonmetallic <br />tr Other <br />ls the spill container minimum <br />capacity five gallons excluding <br />riser volume? <br />X Yes <br />I No* <br />X Yes <br />n No* <br />n Yes <br />X No* <br />tr Yes <br />n No* <br />Method to keep spill container <br />empty <br />X Drain <br />n Pump <br />D Other <br />X Drain <br />tr Pump <br />n Other <br />X Drain <br />n Pump <br />tr Other <br />n Drain <br />n Pump <br />n Other <br />Spill Container Test Results X Pass <br />tr Fail <br />X Pass <br />n Fail <br />E Pass <br />X Fail <br />n Pass <br />n Fail <br />Tank lD <br />Spill Container Manufacturer: <br />Method of Cathodic Protection n Nonmetallic <br />n Other <br />n Nonmetallic <br />n Other <br />fl Nonmetallic <br />n Other <br />n Nonmetallic <br />n Other <br />ls the spill container minimum <br />capacity five gallons excluding <br />riser volume? <br />n Yes <br />n No* <br />tr Yes <br />n No* <br />n Yes <br />n No* <br />n Yes <br />n No* <br />Method to keep spill container <br />empty <br />fl Drain <br />n Pump <br />tr Other <br />n Drain <br />n Pump <br />n Other <br />! Drain <br />n Pump <br />tr Other <br />n Drain <br />! Pump <br />n Other <br />Spill Container Test Results fl Pass <br />n Fail <br />n Pass <br />n Fail <br />! Pass <br />n Fail <br />! Pass <br />! Fail <br />Describe all answers marked "Other," "No," or "Fail" and each proposed remedy. <br />Re-tested 87-91with new dust caps, passed. <br />Diesel nipple and drain valve removed, re-installed with new <br />pipe dope and grease, still failed. <br />* Mark here if: <br />tr Spill containers do not have a minimum capacity of five gallons and require replacement. <br />Additional copies of this page may be attached. <br />Page 2 of 2
The URL can be used to link to this page
Your browser does not support the video tag.