Laserfiche WebLink
N U) <br /> I- <br /> . U <br /> L <br /> ROOF ROOF <br /> N U <br /> 10 FT. LONG #6 SOLID 10 FT. LONG #6 SOLID Q <br /> GROUNDING CONDUCTORG' GROUNDING CONDUCTOR <br /> COILED & TIE-WRAPPED. CATV4 COILED & TIE-WRAPPED. RED INC ARCHITECTS <br /> 1217 J STREET, MODESTO, CA 95354 <br /> J <br /> Z 4'x8'x-YTTB 4 4" PLYWOOD 4'x8'x-Y4" PLYWOOD <br /> o BACKBOARD WITH GREY BACKBOARD WITH GREY SEAL: <br /> FIRE—RETARDANT FINISH. FIRE—RETARDANT FINISH. <br /> a ANCHOR TO WALL. ANCHOR TO WALL. <br /> �OfESS/pA,, <br /> J "9C <br /> N �eStD C.Ski <br /> No. E14303 <br /> * Exp. 6-30-19 <br /> kp 4f" Ne <br /> w qT F—TRIC �? <br /> U F OF CA 1-. <br /> 0 3"E.C. 3"E.C. <br /> 4TH LEVEL 4TH LEVEL <br /> a <br /> 10 FT. LONG #6 SOLID 10 FT. LONG #6 SOLID <br /> GROUNDING CONDUCTORGROUNDING CONDUCTOR CONSULTANT: <br /> o COILED & TIE—WRAPPED. C A TV3 COILED & TIE—WRAPPED. <br /> M <br /> TTB3 HCS.0 <br /> Z4'x8'x�4" PLYWOOD 4'x8'x�'4" PLYWOODN BACKBOARD WITH GREY BACKBOARD WITH GREYFIRE-RETARDANT FINISH. FIRE-RETARDANT FINISH. Engineering <br /> w ANCHOR TO WALL. ANCHOR TO WALL. <br /> v=i 50 years <br /> N <br /> 4512 Feather River Dr#F,Stockton,CA 95219 <br /> 209-478-8270 I www.hcs-eng.com <br /> m Richard C.Smith,PE richardOhcs-eng.com <br /> ❑Bhupendra Patel,PE bhupendm(ohcs-eng.com <br /> 69-16 <br /> ❑Elizabeth Aguilar elizabeth@hcs-eng.com <br /> PROJECT#2018.338 <br /> 3"E.C. 3RD LEVEL 3"E.C. 3RD LEVEL <br /> 10 FT. LONG #6 SOLID 10 FT. LONG #6 SOLID <br /> GROUNDING CONDUCTOR GROUNDING CONDUCTOR <br /> COILED & TIE-WRAPPED. C A TV2 COILED & TIE-WRAPPED. <br /> 4'x8'x:Y4" PLYWOOD TTB 2 4'x8'xY4" PLYWOOD <br /> BACKBOARD WITH GREY BACKBOARD WITH GREY <br /> FIRE—RETARDANT FINISH. FIRE—RETARDANT FINISH. <br /> ANCHOR TO WALL. ANCHOR TO WALL. <br /> by HILTON" <br /> 3"E.C. 2ND LEVEL 3"E.C. 2ND LEVEL <br /> 1#6G (INSULATED), 11 -C CATV BONDING 1#6G (INSULATED), 1,12"C TELECOMMUNICATIONS BONDING z <br /> BACKBONE (CAN), RUN CONTINUOUS FROM THE CAN ON FIRST L J BACKBONE (TBB), RUN CONTINUOUS FROM THE TB ON FIRST LJ w <br /> FLOOR TO THE TB ON THE 2ND FLOOR. BOND CAN ON THE FLOOR TO THE TB ON THE 2ND FLOOR. BOND TB ON THE O <br /> 2ND FLOOR TO TBB WITH A LUG USING 1#6G (INSULATED) 2ND FLOOR TO TBB WITH A LUG USING 1#6G (INSULATED) LL_ <br /> BONDING JUMPER. PROVIDE Yz"C BETWEEN EACH FLOOR BONDING JUMPER. PROVIDE Lz"C BETWEEN EACH FLOOR 1"E.C. Q <br /> AND BOND CONDUIT TO GROUND AT BOTH ENDS. AND BOND CONDUIT TO GROUND AT BOTH ENDS. U <br /> 1#6G (INSULATED), 1A"C 1#6G (INSULATED), 1i"C 1"E.C. <br /> CEILING CEILING <br /> BOND CONDUIT BOND METALLIC -Y4"E.C. WITH BOND CONDUIT BOND METALLIC Y4"E.C. WITH PULL CORD <br /> TO GROUND AT PULL CORD TO GROUND AT <br /> BOTH ENDS CONDUITS (TYPICAL). STUBBED ABOVE <br /> 10 FT. CONDUITS (TYPICAL). STUBBED ABOVE BOTH ENDS STUB CONDUIT(S) 2" ACCESSIBLE <br /> GROUUNDING CONDUCTOR INTO TELECOMM ROOM CEILING.STUB CONDUIT(S) 2" ACCESSIBLE 10 FT. LONG #6 SOLID LONG #6 SOLID INTO CATV ROOM CEILING. GROUNDING CONDUCTOR • <br /> G <br /> MSB COILED & TIE—WRAPPED. C A TV1 MSB COILED & TIE—WRAPPED. FACP ELEV0 W <br /> cli ROUNDING LUG ROUNDING LUG CNTRL <br /> 4'x8'x-Y4" PLYWOOD TTB 1 4'x8'x-Y4" PLYWOOD <br /> cu CATV MAIN BACKBOARD WITH GREY TELECOM MNICATIONS MAIN BACKBOARD WITH GREY <br /> GROUNDING BUSBAR (TMGB), FIRE—RETARDANT FINISH. GROUNDING BUSBAR (TMGB), FIRE—RETARDANT FINISH. <br /> 12'Lx2"WxV4"T CU. ANCHOR TO WALL. 12"Lx2"WxV4 T CU. ANCHOR TO WALL. W <br /> PROVIDE 1#6G (INSULATED), PROVIDE 1#6G (INSULATED), <br /> H <br /> SERVICE V2"C AND BOND TO BUILDING SERVICE 1h C AND BOND TO BUILDING <br /> ENTRANCE STEEL AND MAIN GROUNDING WIREMOLD 2100 PLUGMOLD ENTRANCE STEEL AND MAIN GROUNDING WIREMOLD 2100 PLUGMOLD <br /> EQUIPMENT ELECTRODE SYSTEM AT SERVICE WITH NEMA 5-15R RCPT. EQUIPMENT ELECTRODE SYSTEM AT SERVICE WITH NEMA 5-15R RCPT. <br /> o EQUIPMENT. ON 8" CENTERS. MOUNT EQUIPMENT. ON 8" CENTERS. MOUNT O <br /> ON BOTTOM OF BACKBOARD. ON BOTTOM OF BACKBOARD. <br /> _ PROVIDE DEDICATED CIRCUIT PROVIDE DEDICATED CIRCUIT <br /> O #6AWG TO BLDG. STEEL WITH HANDLE LOCK—ON #6AWG TO BLDG. STEEL WITH HANDLE LOCK—ON TYPICAL DATA, <br /> DEVICE ON BREAKER. DEVICE ON BREAKER. TELEPHONE AND/OR • <br /> vo LTYPICAL TELEVISION TELE/DATA OUTLET W <br /> N STUB AND CAP 4"A.F.F. 12" OUTLET STUB AND CAP 4"A.F.F. 12" <br /> E ON LEFT SIDE OF TB. 1 ST LEVEL ON LEFT SIDE OF M. <br /> 1ST LEVEL <br /> CL <br /> O <br /> +' 2-2" SCH 40 PVC TO PROPERTY LINE. 2-2" SCH 40 PVC TO PROPERTY LINE. LL_ <br /> MIN. 24" BELOW GRADE WITH PULL CORD. MIN. 24" BELOW GRADE WITH PULL CORD. (/) <br /> t SEE ELECTRICAL SITE PLAN. SEE ELECTRICAL SITE PLAN. 0 <br /> + z_ <br /> 3 CAN RISER DIAGRAM NOTES: TELE/DATA RISER DIAGRAM NOTES: 3:: <br /> 1. FLOOR PLANS INDICATE THE EXACT QUANTITY AND LOCATION OF 1. FLOOR PLANS INDICATE THE EXACT QUANTITY AND LOCATION OF < <br /> a ALL TELEVISION OUTLETS. ALL TELEPHONE AND/OR DATA OUTLETS. p <br /> O 2. ALL TELEVISION WIRING AND EQUIPMENT SHALL BE 2. ALL TELEPHONE AND/OR DATA WIRING AND EQUIPMENT SHALL BE <br /> L PROVIDED BY THE OWNER'S CAN SUPPLIER. PROVIDED BY THE OWNER'S TELE/DATA SUPPLIER. zz <br /> O <br /> 2 CATV RISER DIAGRAM , TELEPHONE RISER DIAGRAM o <br /> oE403 NO SCALE E403 NO SCALE N ? <br /> a z <br /> O J <br /> N <br /> Cn <br /> REVISIONS: <br /> Q2 HILTON 10/18/2018 <br /> v <br /> E <br /> o, <br /> c <br /> •3 <br /> v <br /> a� <br /> U <br /> N <br /> U <br /> i <br /> Q <br /> RED PROJECT # 18050 <br /> c <br /> o HILTON # 18-428ND <br /> PLANNING # SPR-18-102 <br /> o PERMIT # - <br /> L APN # 196-270-23 <br /> a� <br /> CL DATE: 11.12.18 <br /> a <br /> DRAWN: BA <br /> a� <br /> CHECKED: RCS <br /> CL <br /> O <br /> U <br /> SHEET TITLE: <br /> •cn TELEPHONE & CATV <br /> _ <br /> RISER DIAGRAMS <br /> •cn3 <br /> N <br /> O <br /> L__ <br /> O <br /> N <br /> C <br /> d <br /> c' SHEET NO.: <br /> •3 <br /> v <br /> E504 <br /> FILE: K:\2018\301-400\RED Tru Hilton Lathrop\E504.dwg Mar 05, 2019 - 5:29pm richard <br />