Laserfiche WebLink
N ' ^ <br /> I- <br /> U <br /> IDLu <br /> � <br /> ROOF <br /> N U <br /> S D D FS <br /> 0 <br /> Wall Opening Protective Materials (CLIA) <br /> RED INC ARCHITECTS <br /> 1. SpecSeal Power Shield Box Inserts,for use with flush device UL Listed Metallic Outlet Boxes without internal C.Wall Design -Stud composition is indicated in the table below.Wall construction shall comply with the 1217 J STREET; MODESTO, CA 95354 <br /> clamps installed with steel mud rings in framed wall assemblies.When protective material is used in outlet boxes individual U300. U400 or V400 Series Wall and Partition Design in the Fire Resistance Directory. S 209.522.8900 <br /> Z on both sides of the wall as directed,the horizontal separation between outlet boxes on opposite sides of the wall D. Metallic Outlet Boxes- Except as indicated in the table below,when steel outlet boxes are used and the F S F F F M <br /> omay be less than 24 in. {610 mm} provided that the boxes are not installed back-to-back. Installation shall comply boxes are interconnected by means of electrical metallic tube or conduit, a ball of putty is to be installed to FIRE ALARM SEQUENCE SEAL: <br /> with the National Electrical Code{NEPA 70}.The max outlet box dimensions, hourly rating,type of stud,use of plug the open end of each electrical metallic tube{EMT}or conduit within the outlet box.When MC cable is <br /> oa stud cavity insulation and type of faceplate are tabulated below.Additional general construction features shall used and/or when the outlet boxes are not interconnected,the ball of putty is not required. BUILDING SYSTEM OUTPUTS CENTRAL COMM. <br /> comply as follows: E. Nonmetallic Outlet Boxes-The box manufacturer is indicated in the table below.Boxes shall bear a 2 hr �,tOf <br /> A. Studs-Unless otherwise specified,the minimum stud width is 3-112 in. (89 mm}. rating under the"Outlet Boxes and Fittings Classified for Fire Resistance"category in the Fire Resistance z zo TS FS F F `,PRP C.S <br /> to B.Stud Cavity Insulation-Where indicated in the table below, stud cavity insulation to consist of min 3-112 in. Directory. o p 0 a z <br /> I (89 mm}thick fiberglass{min 0.5 pcf or 8 kg/m3} or mineral fiber(min 4 pcf or 64 kg/m3}. Unless indicated as ¢ ¢ o J ¢ ~ o <br /> 3RD-5TH LEVEL ti <br /> Max Outlet Box Outlet Outlet Rating, Stud Face Plate Putty U ir U � w Cn i= No. E14303 <br /> Z required, stud cavity insulation is optional. mm Box T e Box Mfr hr Type Ball M o Z J o o a J a Exp. 6-30-19 <br /> 4 x 4 x 2-118 Steel or o z ¢ O < U Q a ¢ < fn 61) <br /> a C.Wall Design-Stud composition is indicated in the table below.Wall construction shall comply with the Steel N.A. 1 Steel No - U10x 102 x 54 dee Wood ¢ Jindividual U300, U400 or V400 Series Wall and Partition Design in the Fire Resistance Directory. 4 x 4 x 2 118 Steel or U aC3 Z a z z o W a v Q Z W a FS J'�,9��FCTRIGp��\� <br /> D.Pad Dimensions -The minimum dimensions of the insert pad are shown in the table below. Pads may be cut 102 x 102 x 54 dee Steel N.A. 1 Wood Plastic Yes ? o J J J U z z 0 0 z TF OF CAI.�EO�i <br /> o to achieve dimensions shown in table and artial insert ads ma be utilized. 4-11116 x 4-11116 x 2-118 Steel or N N ¢ ¢ w ¢ o w z w o w <br /> i 19 x 119 x 54 dee Wood ¢ ¢ X Z zo 0 U ¢ U U <br /> P P y Leel 1 or 2 teal es J J m f- 0 f- <br /> 4-112 x 5 x 2-318 Steel or z z fn vt F z Q o z z J a o S <br /> ¢ Max Outlet Box Pad Size, in. Rating, Cavity Face Plate Steel N.A. 1 or 2 Steel Yes 0 c� o o w t- (- <br /> Product Stud i i 4 x 127 x 60 dee Wood N to to ¢ rn cn 0 z o o ¢ z J F S F F F M <br /> Size. mm mm hr Insulation T N w z - a z a ¢ <br /> N4 112 x 14 x 2-112 Steel or 5 5 <br /> 2 x 3 x 2-114 1-718 x 2-314 Steel N.A. 1 or 2 Steel Yes J m rn o <br /> tZ EP 23 2 Steel No Steel 114 x 127 x 60 a Wood M W w LU 0° 0° U ¢ z N z <br /> 51 x 76 x 57 dee 48 x 7Q `r' > > ¢ ~ 0 <br /> _ 3-3/4 x 4 x 3 Polyvinyl Lamson& Plastic or J ¢ a a o 0 x cn = J W ¢ ¢ jr <br /> 2 x 3 x 2-114 1-718 x 2-314 1 or 2 Wood N.A. J > > w N in in N <br /> cliEP 23 2 Steel Yes Plastic x 102 x 7 e Chloride ions el ¢ ¢ z) rn f5 w J ¢ o N rn m o <br /> 51 x 7 x 57 de 48 x 70 3-314 x 4 x 3 Allied Moulded lastic or z J O ¢ 0 5 _1 w L_ 5 _3 CONSULTANT: <br /> SEQUENCE OF OPERATIONS <br /> X 2 x 3 x 2-114 1-718 x 2 314 Phenolic 1 or 2 wood N.A. o � o � o ¢ w z N W m o o ¢ of m <br /> EP 23 t Steel Yes Plastic or Steel 95 x 102 x 76 dee Prods Steel m � <br /> 1 x 76 x 7 de 4 x 7Q 2 m m m w Z w v w v TS AFS <br /> M 3 314 x 4 x 3 Thomas& Plastic or 2 o o o z z X a 0 w w w a o F F <br /> 2-11$x 4 x 2-11$ 1-718 x 3-314 95 x 102 x 76 dee Polycarbonate Betts 1 or 2 Wood Steel N'A' o v o v 0 v w a x ¢ v 0 0 v <br /> t- EP 24 2 Steel No Steel U ¢ U ¢ U ¢ 0 x w ti N � z z E N <br /> z 54 x 102 x 54 dee 48 x 95 3-314 x 4 x 3 Thomas& Plastic or U ¢ ¢ 2ND LEVEL <br /> Phenolic 1 or 2 Wood N.A. HCS. <br /> 2-118 x 4 x 2-118 1-71$x 3 314 95 x 102 x 7fi dee Betts Steel <br /> EP 24 2 Steel Yes Plastic <br /> N 4 x 102 x 4 d 48 x 95 2-114 x 3-314 x 2-3/4 Polyvinyl Pass& Plastic or ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ N N N N N v) <br /> 1or2 Wood N.A. > J > Engineering EP 24 2-118 x 4 x 2-118 1-718 x 3-314 1 Steel Yes Plastic or Stee! 57 x 95 x 70 dee Chloride a mo r Steel ALARM SOURCE AND TYPE � a F a a a o o a a s w 54 x 102 x 54 dee 48 x 95 U 0 0 0 0 0 0 �' 0 = = <br /> LU ¢ ¢ ¢ ¢ ¢ ¢ ¢ o ¢ to cn S D <br /> N EP 4 x4 x 2.118 3-314 x 95) 2 Steel No Steel 3. SpecSeal Putty Pads,far use with maximum 4 by 4 by 2-118 in.(102 by 102 by 54 mm}deep flush device UL ■ ■ ■■ ■ ■ ■ ■ ■ D FS 50 years <br /> 1 Q2 x 102 x 54 dee 95 x 95 1. MANUAL PULL STATION ALARM <br /> cn Listed Metallic Outlet Boxes installed with steel mud rings and with steel faceplates in 1 hr or 2 hr fire rated <br /> EP 44 4 x 4 x 2-11$ 3-314 x 3-314 2 Steel Yes Plastic 2. BUILDING SMOKE DETECTOR 4512 Feather River Dr#F,Stockton,CA 95219 <br /> 102 x 102 x 4 e 5 x 95 gypsum board wall assemblies constructed with min 5-112 in. {140 mm}wide wood or steel studs and with stud N o N O N E M E N 209-478-8270 1 www.hcs-eng.com <br /> EP 44 <br /> 4 x4 x 2-118 3-314 x 3-314 1 Steel Yes Plastic or Steel cavities filled with fiberglass{nom 0.5 pcf or 8 kg/m3}or mineral fiber{nom 4 pcf or 64 kg/m3}insulation.When 3. DUCT DETECTOR ALARM S <br /> 102 x 102 x 54 dee 95 x 95 protective material is used on outlet boxes on both sides of the wall as directed.the boxes may be installed <br /> 4-11116 x 4-11116 x 2-1/8 4-112 x 4-112 4. SMOKE DETECTOR DIRTY/MALFUNCTION - ALL 0 MEN 0 1131 Richard C.Smieh,PE richard@hcs-e-encs <br /> EP 45 11 x 11 x 4 114 x 114 1 or 2 Steel Yes Plastic or Steel back-to-back provided that the boxes on opposite sides of the wall are not interconnected with conduit or,when F S F F F M 11 Bhupendra Patel,PE Bhupendra@hcs-eng.com <br /> 4-112 x 5 x 2-31$ 4-112 x 4-112 conduit is used,the open end of the conduit within the outlet box is filled with a ball of putty. Installation shall 5. SPRINKLER WATERFLOW NONE M E N 1 EC TO TELE. ❑Elizabeth Aguilar elizabeth@hcs-eng.com <br /> EP 45 114 x 127 x 60 dee 114 x 114 1 or 2 Steel Yes Plastic or Steel comply with the National Electrical Code(NFPA 70).Min 3116 in. (5 mm)thick moldable putty pads are to be 6. SPRINKLER TAMPER <br /> 4-112 x 14 x 2-112 4-112 x 13-314 installed to completely cover the exterior surfaces of the outlet box(except for the side of the outlet box against PROJECT#2018.338 <br /> EP 45 114 x 356 x 64 dee 114 x 349 1 or 2 Steel Yes Plastic or Steel the stud}and to completely seal against the stud within the stud cavity. Adjoining pieces of moldable putty pads 7. FIRE ALARM AC POWER FAILURE N o 0 BOARD FOR <br /> to be overlapped approx 112 in. (13 mm)at the seam.An additional 3/16 in.(5 mm)thickness of putty to be 8. FIRE ALARM SYSTEM LOW BATTERY AUTODAILER <br /> 2. SpecSeal Putty Pads,for use with flush device UL Listed Metallic Outlet Boxes installed with steel mud rings or formed around the connector securing the end of each Type MC cable,electrical metallic tube{EMT}or conduit 9. OPEN CIRCUITCONNECTION. FACP F RA <br /> UL Listed Nonmetallic Outlet Boxes in framed wall assemblies.When protective material is used on outlet boxes to the box. IME <br /> on both sides of the wall as directed,the horizontal separation between outlet boxes on opposite sides of the wall 4. SpecSeal EP23, EP24 and EP44 Power Shield Box Inserts and SpecSeal Putty Pads,for use with maximum 10. GROUND FAULT N o 0 <br /> may be less than 24 in. {610 mm} provided that the boxes are not installed back-to-back. Installation shall comply 4 by 4 by 1-112 or 2-118 in.{102 by 102 by 38 or 54 mm}deep flush device UL Listed Metallic Outlet Boxes 11. NOTIFICATION APPLIANCE CIRCUIT SHORT 1001 101 T 1010101 IN TS FS <br /> with the National Electrical Code(N FPA 70). Min 3116 in. (5 mm)thick moldable putty pads are to be installed to installed with steel mud rings and with steel or plastic faceplates in 1 hr or 2 hr fire rated gypsum board wall 12. SYSTEM RESET (SEE NOTES 1 AND 2 BELOW FOR ACTIONS) 1ST LEVEL <br /> completely cover the exterior surfaces of the outlet box{except for the side of the outlet box against the stud} and assemblies constructed with min 3-112 in.(89 mm)wide wood or steel studs.When both protective materials are <br /> to completely seal against the stud within the stud cavity.Adjoining pieces of moldable putty pads to be used with outlet boxes on both sides of the wall as directed, the boxes may be installed back-to-back provided 1 PT-11 <br /> overlapped approx 112 in.(13 mm) at the seam.An additional 3116 in. (5 mm)thickness of putty to be formed that the backs of the boxes are minimum 112 in.(13 mm) apart and provided that the boxes are not <br /> around the connector securing the end of each Type MC cable,electrical metallic tube(EMT)or conduit to the interconnected. Installation shall comply with the National Electrical Cade(NFPA 70).Min 3116 in.(5 mm)thick NOTES: <br /> moldable putty paor sure outlet (except t <br /> ds are to be installed to completely cover the exterior of the bfor box.When nonmetallic box is used with Type NM cable,a 3116 in. {5 mm}thickness of putty shall be formed 1. SYSTEM RESET' SHALL CLEAR ALL DETECTOR AND MANUAL ALARM SIGNALS, STOP AND RESET <br /> around the cable at its connection to the box and extending a min of 1 in. (25 mm).The box composition, max side of the outlet box against the stud)and to completely seal against the stud within the stud cavity.Adjoining THE PRE-DISCHARGE COUNTDOWN, AND STOP TRANSMISSION OF ALL ALARM SIGNALS TO THE <br /> device dimensions, hour) ratio type of stud and a of faceplate are tabulated below.Additional general pieces of moldable putty pads to be overlapped approx 112 in. (13 mm) at the seam.An additional 3116 in.(5 mm) <br /> y rating, yP type P g thickness of putty to be formed around the connector securing the end of each Type MC cable, electrical metallic MAIN PANEL <br /> construction features shall comply as follows: 2. SYSTEM SHALL BE PROGRAMMED SUCH THAT THE SYSTEM CAN BE RESET WHILE THE MANUAL , FIRE ALARM RISER DIAGRAM <br /> A. Studs-Unless otherwise specified,the minimum stud width is 3-112 in. (89 mm). tube(EMT)or conduit to the box.An insert pad shall be installed to completely cover the back inside surface of ABORT BUTTON IS ACTIVATED. <br /> B.Stud Cavity Insulation-Unless indicated as required, stud cavity insulation is optional and may consist of each outlet box. 3. SYSTEM SHALL HAVE A 3 BEAT TEMPORAL SOUND PATTERN. E402 NO SCALE <br /> min 3-112 in. {89 mm}thick fiberglass{min 0.5 pcf or 8 kg/m3}or mineral fiber(min 4 pcf or 64 kg/m3). <br /> FIRE ALARM RISER NOTES: by HILTON' <br /> Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 1. FACP SHALL HAVE A MINIMUM 24HR. BATTERY BACKUP. <br /> Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 VReproduced courtesy of Underwriters Laboratories, Inc. 2. FACP SHALL BE CONNECTED TO A UL APPROVED CENTRAL STATION. <br /> L <br /> Reproduced courtesy of Underwriters Laboratories, Inc. u� Created or Revised: October 09,2009 CLIV 3. ZONE PER NFPA 72 AND MANUFACTURER'S RECOMMENDATIONS <br /> Ct-lV 1►.7T1 Created or Revised: October 09,2069 STI (800)992-1180■(908)525-8000.FAX(908)231-8415.E-Mai l:techssrv@stifirestop.com •Website:www.stifirestop.com PAGE 2 OF 2 WITH NO ONE ZONE EXCEEDING 15,000 S.F. PER FLOOR. <br /> STI 11 <br /> (800)992-1180•(908)526-8000.FAX(908)231-8415•E-Mail.-techsery@stifirestap.com •Website.-www.stifirestap.com PAGE 1 OF 4. SEE PLANS FOR EXACT DEVICE QUANTITY AND LOCATIONS. a <br /> 5. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. Z <br /> 6. LOCATE ANNUNCIATOR AS DIRECTED BY LOCAL OFFICIAL 0 <br /> 7. ALL FIRE ALARM WIRING SHALL BE PLENUM-RATED. LL_ <br /> 8. FIRE ALARM DEVICES IN GUEST ROOMS SHALL COMPLY WITH F.B.C. AND NFPA 72. Q <br /> 9. PROVIDE ELEVATOR RECALL U <br /> 10. VERIFY QUANTITY AND LOCATIONS) OF ALL TAMPER AND FLOW SWITCHES <br /> System No.W-L-1049 WITH SPRINKLER CONTRACTOR. <br /> F Ratings-1 and 2 Hr(See Item 1) <br /> T Rating -0 Hr System No. W-L-3210 <br /> L Rating At Ambient-Less Than 1 CFM/sq ft F Ratings- 1 and 2 hr{See Item 1} <br /> L Rating At 400 F-Less Than 1 CFM/sq ft T Rating- 314 Hr <br /> A 1B Z <br /> � 1B • <br /> ui <br /> W <br /> A <br /> CID Q <br /> � 413 4. Firestop System-The firestop system shall consist of the following: <br /> + 2 4A 3 A. Packing Material-When required{See table in Item 3B}, min 1 in. (25 mm}thickness of min 4.0 of{64 kg/m3 mineral <br /> • p } <br /> wool batt insulation firmly packed into each end of sleeve as a permanent form. Packing material to be recessed from each W <br /> L ... <br /> - 11711,111 111 end of sleeve as required to accommodate the required thickness of fill material. <br /> U 3 ....{.. _ B. Fill, Void or Cavity Material*-Sealant or Putty- Fill material applied to appropriate thickness within steel sleeve,flush <br /> _ with edges of steel sleeve on both surfaces of wall. Min 112 in. (13 mm)diam bead of sealant or"rope"of putty shall be <br /> cm A A - applied around the perimeter of the sleeve on each side of the wall when sleeve extends beyond surface of wall.See tableILLJ <br /> O <br /> Section -A _ 3 111 111 below for fill material thickness requirements. <br /> -:::_ <br /> 0 1. Wall Assembly-The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in 4B Sealant Series <br /> Putty Type Thickness, Packing Material � <br /> 4A In. mm Required • <br /> o the manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and 2 SpecSeal Series SSS Sealant 1/2 in. (13) Yes W <br /> •co shall include the following construction features: 1 A or LCISealant <br /> En A SpecSeal Series SSS Sealant <br /> E A. Studs-Wall framing may consist of either wood studs or steel channel studs.Wood studs to consist of nom 2 by 4 in.(51 or LCI Sealant 1 in. (25) No <br /> a by 102 mm} lumber spaced 16 in. {406 mm}OC.Steel studs to be min 3-518 3-112 in. (89 mm)wide and spaced max 24 in. Section A-A SpecSeal Putty 1 in. (25) No *40 <br /> {610 mm}OC. When steel studs are used and the diam of opening exceeds the width of stud cavity,the opening shall be <br /> framed on all sides using lengths of steel stud installed between the vertical studs and screw-attached to the steel studs at 0 <br /> +' each end.The framed opening in the wall shall be 4 to 6 in. (102 to 152 mm)wider and 4 to 6 in.{102 to 152 mm} higher SPECIFIED TECHNOLOGIES INC -SpecSeal Series SSS Sealant,SpecSeal LCI Sealant or SpecSeal Putty LL_+, 1. Wall Assembly-The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the <br /> v than the diam of the penetrating item such that,when the penetrating item is installed in the opening, a 2 to 3 in. (51 to 76 manner specified in the individual U300.U400 or V400 Series Wall and Partition Designs in the UL Fire Resistance Directory `Bearing the UL Classification Mark (/) <br /> mm)clearance is present between the penetrating item and the framing on all four sides. and shall include the following construction features: Z <br /> '3 B. Gypsum Board'-518 in.(16 mm)thick,4 ft{1.22 m}wide with square or tapered edges.The gypsum board type, A. Studs-Wall framing may consist of either wood studs or steel channel studs.Wood studs to consist of nom 2 by 4 in.(51 <br /> thickness, number of layers,fastener type and sheet orientation shall be as specified in the individual U300 or U400 Q <br /> _0 thickness. 102 mm) lumber spaced 16 in.{406 mm} OG. Steel studs to be min 3-112 in.{76 mm}wide and spaced max 24 in. {610 <br /> 0 Series Design in the UL Fire Resistance Directory.Max diam of opening is 26 in. {660 mm}for steel stud walls.Max diam mm} OC. W <br /> •O of opening is 14-112 in.(368 mm}for wood stud walls. <br /> U B. Gypsum Board'- Thickness, number of layers,fastener type and sheet orientation shall be as specified in the individual Z <br /> L The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is U300,U400 or V400 Series Design in the UL Fire Resistance Directory.Max diam of opening is 4-112 in.(114 mm). 0 <br /> 0 installed. 1- <br /> The hourly F rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is U <br /> 0 1A. Metallic Sleeve-(Optional, Not Shown)-Cylindrical sleeve fabricated from min 0.016 in. {0.41 mm}to max 0.105 in.(2.7 installed. O <br /> mm)thick sheet steel. Length of steel sleeve to be equal to the thickness of wall. Longitudinal seam of sleeve welded or <br /> 2. Steel Sleeve-Nom 4 in.(102 mm)diam (or smaller)steel electrical metallic tubing{EMT}.steel conduit or Schedule 5{or <br /> 0 overlapped min 1 in. (25 mm}.The ends of the steel sleeve shall be flush or recessed max 114 in.{6 mm}from wall surfaces. heavier}steel pipe sleeve friction-fitted into wall assembly.Sleeve may be installed flush with or extend up to 18 in.(46 cm) N = <br /> 2. Through Penetrant-One metallic pipe,conduit or tubing to be installed either concentrically or eccentrically within the beyond one or both wall surfaces. ZCID I- <br /> firestop system. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular.TheJ <br /> 3. Cables-Aggregate crass-sectional area of cables in steel sleeve to be max 48 percent of the aggregate cross-sectional area U <br /> annular space between pipe,conduit or tubing and periphery of opening shall be min 0 in.(0 mm, point contact)to max 2 in. of the sleeve. Cables to be bundled and rigidly supported on both sides of wall assembly.The annular space between the <br /> m {51 mm}. Pipe,conduit or tubing to be rigidly supported on both sides of wall assembly.The following types and sizes of cables and the sleeve shall be min 0 in.(point contact)to max 1-112 in.(38 mm).Any combination of the following types and <br /> v metallic pipes,conduits or tubing may be used: sizes of copper conductor cable may be used: <br /> A. Steel Pipe-Nom 24 in. (610 mm)diam(or smaller) Schedule 10(or heavier)steel pipe. A. Max 200 pair No.AWG(or smaller)copper conductor cable with polyvinyl chloride{PVC}jacketing and insulation. REVISIONS: <br /> 0 <br /> B. Iran Pipe-Nom 24 in. {610 mm}diam{or smaller}cast or ductile iron pipe. B. Max 3/C No.210 AWG(or smaller)aluminum or copper conductor service entrance cable with PWC insulation and jacket. Q HILTON 10/18/2018 <br /> v C. Conduit-Nom 4 in. {102 mm}diam(or smaller) steel electrical metallic tubing, nom 6 in.{152 mm}diam(or smaller)steel C. Max 31C No.8 AWG (or smaller) nonmetallic sheathed{Ramex}cable with copper conductors, PVC insulation and jacket. <br /> o conduit or nom 1 in. (25 mm)diam(or smaller)flexible steel conduit. <br /> � D. Max 71C No.210 AWG(or smaller)multiconductar power and control cables with XL PE or PVC insulation and }CLPE or PVC <br /> D. Copper Tubing-Nom 6 in.(152 mm)diam(or smaller)Type L(or heavier)copper tubing. jacket. <br /> E. Copper Pipe-Nom 6 in. (152 mm)diam(or smaller)Regular{or heavier}copper pipe. E. Max RG/U (or smaller)coaxial cable with fluorinated ethylene insulation and jacketing. <br /> •0 3. Fill, Void or Cavity Material*-Sealant-Min 518 in. (16 mm)thickness of fill material applied within annulus,flush with both F. Max 62.5148 fiber optic cable with PVC insulation and jacketing. <br /> -`v surfaces of wall.At the point contact location between through penetrant and gypsum board, a min 318 in. (10 mm)diam bead Ga Max 4 pair No.24 AWG (or smaller)copper conductor data cable with PVC insulation and jacket. <br /> 0 of fill material shall be applied at the gypsum board/through penetrant interface on both surfaces of wall. <br /> t H. Max 41C No.210 aluminum or copper conductor aluminum or steel Metal-Clad#or Arm ored-Cl ad#cable. <br /> t- SPECIFIED TECHNOLOGIES INC -SpecSeal Series SSS Sealant or SpecSeal LCI Sealant <br /> "Bearing the UL Classification Mark <br /> m <br /> Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 <br /> CID Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876 <br /> Reproduced courtesyat Underwriters Laboratories, Inc. <br /> v Reproduced courtesy of Underwriters Laboratories, Inc. u� p ry ` Reproduced courtesy of Underwriters Laboratories, Inc. u� <br /> T1 Created or Revised: December 14,201{7T1 Created or Revised: Jan uary 26,2011 W E 3216 Created or Revised: January 26, 2011 <br /> Q 1 W-L-1 049 STI {800)992-1180■{908)526-8000■FAx{908]231-8415.E-Mail:techserv@st4irestop.com ■Website:www.st&restop.com W L OF 2 W-L-3210 <br /> U (800)992-1180■(908)526-8000■FAX{908)231-8415•E-Mail:techsery@stifirestop.com■Website.www.stifirestop.com PAGE 1 OF 1 PAGETI (800)992-1180.(908)526-8000.FAX(908)231-8415•E-Maii:techsery@stifirestap.mm■Website Yvww.stifirestop.com PAGE 2 OF2 RED PROJECT # 18050 <br /> C <br /> o HILTON # 18-428ND <br /> PLANNING # SPR-18-102 <br /> o PERMIT # - <br /> a� <br /> APN # 196-270-23 <br /> o DATE: 11.12.18 <br /> 0- <br /> DRAWN: BA <br /> a� <br /> CHECKED: RCS <br /> v� <br /> a <br /> 0 <br /> U <br /> SHEET TITLE: <br /> •U) FIRE RISER DIAGRAM <br /> _ <br /> FIRE RATED PENETRATIONS <br /> •Cn3 <br /> i <br /> N <br /> s <br /> 0 <br /> i <br /> 0 <br /> a� <br /> c <br /> 0- <br /> c' SHEET NO.: <br /> •3 <br /> v <br /> E505 <br /> FILE: K:\2018\301-400\RED Tru Hilton Lathrop\E505.dwg Mar 05, 2019 - 5:29pm richard <br />