Laserfiche WebLink
Engineered Septic System Report Irerracon <br /> Jeremy Winery Property Lodi, California <br /> October 1, 2020 Terracon Project No. NA197008 <br /> Boring Depth Interval Soil Type Unified Soil <br /> (feet) Classification <br /> 25.0 Silty sand, fine to medium SM <br /> grained, brown, very dense <br /> *table taken from the nitrate loading/soil suitability study dated May 7, 2020. <br /> Stratification boundaries on the table represent the approximate location of changes in soil types; <br /> in situ, the transition between materials may be gradual. The location for each of the borings can <br /> be found in Appendix A of this report. <br /> 3.2 Percolation Test <br /> The percolation tests were conducted in accordance with the requirements of the San Joaquin <br /> County Percolation Test Procedure (Form: EHD 42-01-002 Revised 08-23-2011). On March 22, <br /> 2019 the shallow boring percolation tests B1 at 3.5 feet bgs and B2 at 3.5 feet bgs were <br /> performed. The deep boring B3 at 25.0 feet bgs percolation test was conducted on April 5, 2019. <br /> As water remained in the bottom of boring B1, Terracon conducted the percolation test by <br /> following Procedure #1. Approximately 0.5 feet of clear water was added above the top of the <br /> gravel and the drop in water level was recorded after a 30 minute period. <br /> There was no water remaining in the test holes at borings B2 and B3; therefore, Terracon <br /> conducted the percolation tests by following Procedure #2. Terracon added clear water <br /> approximately 0.5 feet above the top of the gravel and recorded the drop in water level at thirty <br /> minute intervals over a four hour period. Measurement of the water level during the percolation <br /> test was from a fixed reference point on the PVC casing using a calibrated Solinst electric water <br /> level detector with a depth accuracy of 0.01 feet. All tabulated values on the field data sheet are <br /> in decimal feet. The percolation test for borings B2 and B3 were observed by Mr. Naseem Ahmed, <br /> EHD representative. <br /> The approximate location of the test hole is indicated on the attached Appendix A. Below is a <br /> summary of the percolation test results corrected for a gravel packed hole. <br /> Percolation Rate Summary <br /> Location Depth, ft Percolation Rate (min/inch) <br /> B1 3.5 250 <br /> B2 3.5 125 <br /> B3 25.0 125 <br /> Based on the percolation tests results, the two shallow borings at 3.5 feet bgs failed to achieve a <br /> passing percolation rate of 60 minutes per inch or less for standard leachfields. Additionally, the <br /> deep boring percolation test at 25 feet bgs failed to have a passing percolation rate of at least 30 <br /> Responsive ■ Resourceful ■ Reliable 3 <br />