Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> -- --- COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date : <br /> Nella Oil #487 983 Moffat Blvd , Manteca July 22 , 2021 <br /> UST System Observations <br /> 312 HSC 25290.2(d) Monitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004) ❑ V ❑ R ❑ COS <br /> 313 HSC 25290A (d) Monitoring system incapable of detecting entry into secondary containment (post-Jul 2004) ❑ V ❑ R ❑ COS <br /> 314 CCR 2631 (g) , 2632(c) Failure to continuously monitor interstitial space with audible-visual alarm system (pre-Jul 2004) ❑ V ❑ R ❑ COS <br /> (2) <br /> 315 HSC 25290. 1 (e) Failure to maintain interstitial space to detect leaks before release to environment (post-Jul 2004) ❑ V ❑ R ❑ COS <br /> 316 CCR 2636, 2643(c)(1 ), Failure to install a line leak detector ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow ■ V ■ R ■ COS <br /> 318 CCR 2635, 2637. 1 , Failed to meet spill container requirements ■ V ❑ R ❑ COS <br /> 126651 2712 <br /> 319 CCR 2635, 2637.2, Failure to comply with overfill prevention equipment requirements ❑ V ❑ R ❑ COS <br /> 1266512712 <br /> 320 CCR 2635(c)(1 ) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 321 HSC 25299(a)(9) Leak detection equipment disabled or tampered with ❑ V ❑ R ❑ COS <br /> 322 CCR 2717A (g) Removed , defaced, altered, or otherwise tampered with red tag ❑ V ❑ R ❑ COS <br /> 323 CCR 2717. 1 (1) ; HSC Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V ❑ R ❑ COS <br /> 25292.3(c) <br /> 324 HSC 25292.3(c)(1 )(C) Allowed dispensing from a UST that has a red tag affixed to the fill pipe ❑ V ❑ R ❑ COS <br /> r32632CCR 2635, 2636(b) , Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662, 2712 <br /> CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666(b&e) <br /> CCR 2638(a) , 2641 (1) Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions ❑ V ❑ R ❑ COS <br /> 328 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> L330331 <br /> CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> CCR 2636(f), 2666(c), Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm ❑ V ❑ R ❑ COS <br /> 2666(f)HSC 25281 .6(a) Failure of unburied below-grade emergency generator system to meet exemption conditions ❑ V ❑ R ❑ COS <br /> 332 HSC 25283. 5(a) Failure of unburied below-grade UST system to meet exemption conditions ❑ V ❑ R ❑ COS <br /> 333 CCR 2666(b)(2) Failure to upgrade single-walled pipe to double-walled interstitially monitored pipe when repaired ❑ V ❑ R ❑ COS <br /> 334 CCR 2670(b)(e)(f) , Failure to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 2671 <br /> 335 HSC 25298(c); CCR Failure to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2670, 2672 <br /> 336 CCR 2638(f) , 26410) Failure to affix a tag/sticker on each monitoring equipment certified, repaired, or replaced ❑ V ❑ R ❑ COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Safe suction piping not properly sloped or check valve incorrectly located ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring and maintain records for single-walled conventional suction (pre-1984) ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d), 2661 (0 Failure to conduct 0. 1 gph integrity test for single-walled conventional suction systems (pre-1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643(e), 2661 (f) Failure to conduct 0. 1 gph test on single-walled gravity piping biennially or post repair (pre-1984) ❑ V ❑ R ❑ COS <br /> FA0003593 PR0231691 SCO01 07/22/2021 <br /> EHD 2M1 Rev. 9/16/2020 Page 3 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464- 0138 1 www. sjgov. org /EHD <br />