SAN 10 A Q U I N Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date: <br /> Nella Oil #487 983 Moffat Blvd , Manteca July 22 , 2021 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 208 CCR 2716 (a-e) Failure to comply with the designated operator inspection requirements . <br /> 1 ) OBSERVATION : The designated operator failed to check and note the correct test dates for the overfill <br /> prevention equipment on the designated operator inspection reports. The incorrect date stated is 11 /2019 , the <br /> correct date is 11 /29/2018. <br /> REGULATION GUIDANCE : During the inspection , the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done . <br /> CORRECTIVE ACTION : Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> 2 ) OBSERVATION : The designated operator failed to check and note all required items on the visual inspection <br /> reports . The incorrect and missing information included the following from the inspection reports : <br /> -The DO inspection reports of 07/ 1 /2021 and 06/07/2021 left section VI blank ( Name of owner/operator, signature <br /> and date signed ) . <br /> REGULATION GUIDANCE : During the visual inspection , the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION : Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports . <br /> This is a repeat violation , Class Il . <br /> 317 CCR 2636 (f) (2 ) Failure of the line leak detector to detect a 3 . 0 gph leak at 10 psi and restrict or shut off flow. <br /> OBSERVATION : The 87 VMI line leak detector failed to detect a leak when tested . <br /> REGULATION GUIDANCE : All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi . <br /> CORRECTIVE ACTION : The service technician adjusted the leak detector, retested it, and it passed . <br /> This was corrected on site. <br /> This is a repeat violation , Class II , <br /> FA0003593 PR0231691 SCO01 07/22/2021 <br /> EHD 23-01 Rev. 9/16/2020 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjgov. org/EHD <br />