My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HEINZ
>
2746
>
1900 - Hazardous Materials Program
>
PR0520156
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2021 4:21:07 PM
Creation date
3/25/2021 2:37:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0520156
PE
1921
FACILITY_ID
FA0010224
FACILITY_NAME
CHEMICAL TRANSFER CO INC - Superior Tank Wash.
STREET_NUMBER
2746
STREET_NAME
HEINZ
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16707033
CURRENT_STATUS
01
SITE_LOCATION
2746 HEINZ ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAFETY DATA SHEET <br /> LKW1268 v9.2 AXALTA <br /> en/US <br /> Suitable extinguishing media <br /> Water spray,Dry chemical,Foam <br /> Extinguishing media which shall not be used for safety reasons <br /> High volume water jet <br /> Hazardous combustion products <br /> CO,CO2,smoke,and oxides of any heavy metals that are reported in"Composition,Information on Ingredients"section. <br /> Fire and Explosion Hazards <br /> Avoid heating above flash point. <br /> Special Protective Equipment and Fire Fighting Procedures <br /> Full protective flameproof clothing should be worn as appropriate.Wear self-contained breathing apparatus for firefighting if <br /> necessary. In the event of fire,cool tanks with water spray. Do not allow run-off from fire fighting to enter public sewer systems or <br /> public waterways. <br /> 6. Accidental release measures <br /> Procedures for cleaning up spills or leaks <br /> Ventilate area. If heated above the flashpoint,remove sources of ignition. Prevent skin and eye contact and breathing of vapor.Wear <br /> a properly fitted air-purifying respirator with organic vapor cartridges(NIOSH approved TC-23C),eye protection,gloves and <br /> protective clothing. Confine,remove with inert absorbent,and dispose of properly. <br /> Environmental precautions <br /> Do not let product enter drains. Notify the respective authorities in accordance with local law in the case of contamination of rivers, <br /> lakes or waste water systems. <br /> 7. Handling and storage <br /> Precautions for safe handling <br /> Observe label precautions.Close container after each use. If heated above its flash point,this must be handled as if it were a <br /> flammable liquid. Do not transfer contents to bottles or unlabeled containers.Wash thoroughly after handling and before eating or <br /> smoking. Do not freeze. If material is a coating:do not sand,flame cut,braze or weld dry coating without a NIOSH approved air <br /> purifying respirator with particulate filters or appropriate ventilation,and gloves.Combustible dust clouds may be created where <br /> operations produce fine material(dust).Avoid formation of significant deposits of material as they may become airborne and form <br /> combustible dust clouds.Build up of fine material should be cleaned using gentle sweeping or vacuuming in accordance with best <br /> practices. Cleaning methods(e.g. compressed air)which can generate potentially combustible dust clouds should not be used. <br /> Advice on protection against fire and explosion <br /> Solvent vapours are heavier than air and may spread along floors.Vapors may form explosive mixtures with air and will burn when an <br /> ignition source is present. Always keep in containers of same material as the original one. Never use pressure to empty container: <br /> container is not a pressure vessel. The accumulation of contaminated rags may result in spontaneous combustion, Good <br /> housekeeping standards and regular safe removal of waste materials will minimize the risks of spontaneous combustion and other <br /> fire hazards. <br /> Storage <br /> Requirements for storage areas and containers <br /> Observe label precautions. Store in a dry,well ventilated place away from sources of heat,ignition and direct sunlight. No smoking. <br /> Prevent unauthorized access.Containers which are opened must be carefully resealed and kept upright to prevent leakage. <br /> Advice an common storage <br /> Store separately from oxidizing agents and strongly alkaline and strongly acidic materials. <br /> OSHA/NFPA Storage Classification: IIIB <br /> Q 2019 Axalta Coating Systems,L. G and all affiliates.All rights reserved. 3.9 <br /> Copies may be made only for those using Axalta Coating Systems products. 2019-04-24 <br /> N <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.