My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2021 9:11:21 AM
Creation date
3/29/2021 2:58:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SHELL 1-5 1 717 W EIGHTH ST, STOCKTON March 31, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The designated operator failed to document all the alarms from the attached alarm history on the <br /> 11/17/2020, 12/16/2020, and 02/18/2021 designated operator inspection reports and failed to check that they were <br /> responded to appropriately. The missing alarms include: <br /> L2: 10/20/2020 and 10/29/2020 <br /> L8: 12/13/2020 and 01/27/2021 <br /> REGULATION GUIDANCE: During the inspection,the designated operator shall review the alarm history since the <br /> previous inspection, check that each alarm was documented and responded to appropriately, and attach a copy of <br /> the alarm history with documentation taken in response to any alarms to the inspection report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> --------------------- <br /> --------------------- <br /> OBSERVATION: The designated operator failed to check and note the correct test dates for the overfill prevention <br /> inspection and secondary containment test on the Octobor 2020 through March 2021 designated operator <br /> inspection reports. The correct test date for overfill prevention is 03/06/2019 and the correct test date for secondary <br /> containment is 04/23/2018. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> --------------------- <br /> --------------------- <br /> OBSERVATION: The designated operator inspections for the following months were performed more than 30 days <br /> after the previous inspection: <br /> - Initial inspection on 02/10/2020, next inspection performed on 03/18/2020 (36 days) <br /> - Initial inspection on 09/13/2020, next inspection performed on 10/20/2020 (37 days) <br /> - Initial inspection on 12/16/2020, next inspection performed on 01/21/2021 (36 days) <br /> REGULATION GUIDANCE: The designated operator visual inspections shall be conducted within 30 days or less of <br /> the previous inspection. <br /> CORRECTIVE ACTION: Ensure that all designated operator inspections are performed within the required time <br /> frames. <br /> ------------------------------ <br /> ------------------------------ <br /> OBSERVATION: Designated operator reports were not signed within the required time frame. The March 2020 <br /> through September 2020 reports were not signed and dated by the owner/operator and the owner/operator failed to <br /> document follow-up action on the 10/20/2020 report. <br /> FA0015274 PR0522448 SCO01 03/31/2021 <br /> EHD 23-01 Rev.9/16/2020 Page 6 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.