Map ID MAP FINDINGS <br /> Direction <br /> Distance EDR ID Number <br /> Elevation Site Database(s) EPA ID Number <br /> HUSKY CRANE INC (Continued) 1000273351 <br /> City,State,Zip: STOCKTON,CA 95205 <br /> Site ID: 273240 <br /> CERS ID: 627775 <br /> CERS Description: Industrial Facility Storm Water <br /> Violations: <br /> Site ID: 273240 <br /> Site Name: MAXIM CRANE WORKS <br /> Violation Date: 05-20-2019 <br /> Citation: HSC 6.67 25270.4.5(a)-California Health and Safety Code,Chapter <br /> 6.67,Section(s)25270.4.5(a) <br /> Violation Description: Failure to perform integrity and leak testing of buried piping at the <br /> time of installation, modification,construction,relocation,or <br /> replacement. <br /> Violation Notes: Returned to compliance on 05/14/2020. No integrity test results were <br /> available for the buried used oil piping.According to the SPCC Plan, <br /> the piping was modified in 2007 to provide cathodic protection. Buried <br /> piping shall be tested for integrity and leaks at the time of <br /> installation,modification,construction,relocation,or replacement. <br /> Provide records of testing or immediately perform integrity and leak <br /> testing of this piping and ensure that piping is tested when required, <br /> or provide equivalence as allowed by CFR 112.7(a)(2). <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: APSA <br /> Violation Source: CERS <br /> Site ID: 273240 <br /> Site Name: MAXIM CRANE WORKS <br /> Violation Date: 05-20-2019 <br /> Citation: HSC 6.67 25270.4.5(a)-California Health and Safety Code,Chapter <br /> 6.67,Section(s)25270.4.5(a) <br /> Violation Description: Failure to amend the SPCC Plan within 6 months: 1.When the facility <br /> has had a change in design,construction,operation,or maintenance <br /> which affects the facilityG s discharge potential.AND/OR 2.To <br /> include more effective proven technology at the time of the 5-year <br /> SPCC Plan review and evaluation. <br /> Violation Notes: Returned to compliance on 06/03/2020.The tanks described in the SPCC <br /> plan as the 165 gallon gear oil and 275 gallon transmission oil have <br /> been removed from the facility per facility personnel.The tank <br /> described as the 600 gallon hydraulic oil tank has been replaced with <br /> a 165 gallon tank and the 570 gallon engine oil tank has been replaced <br /> by a 400 gallon tank,per facility personnel.A tank holding more than <br /> 55 gallons of hydraulic oil for an oil filter crusher was observed in <br /> the main shop but was not mentioned in the SPCC plan.This tank may <br /> qualify as operational equipment.Amend the SPCC Plan for your <br /> facility in accordance with the general requirements in-112.7,and <br /> with any specific section of this part applicable to your facility, <br /> when there is a change in the facility design,construction, <br /> operation,or maintenance that materially affects its potential for a <br /> discharge as described in-112.1(b). Examples of changes that may <br /> require amendment of the Plan include,but are not limited to: <br /> commissioning or decommi <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: APSA <br /> Violation Source: CERS <br /> Site ID: 273240 <br /> Site Name: MAXIM CRANE WORKS <br /> TC6327721.2s Page 368 <br />