Laserfiche WebLink
Map ID MAP FINDINGS <br /> Direction <br /> Distance EDR ID Number <br /> Elevation Site Database(s) EPA ID Number <br /> HUSKY CRANE INC (Continued) 1000273351 <br /> Violation Date: 05-27-2016 <br /> Citation: HSC 6.67 25270.4.5(a)-California Health and Safety Code,Chapter <br /> 6.67,Section(s)25270.4.5(a) <br /> Violation Description: Failure to adequately describe the physical layout of the facility,or <br /> no description of the physical layout of the facility included within <br /> the SPCC plan. <br /> Violation Notes: Returned to compliance on 05/21/2019.The facility map did not include <br /> the accurate locations of all aboveground tanks at this facility and <br /> did not include any petroleum storage inside the shop.The Spill <br /> Prevention,Control,and Countermeasure(SPCC)Plan shall include a <br /> facility diagram which must mark the location and contents of each <br /> fixed storage container and the storage area where mobile or portable <br /> containers are located. It must identify the location of and mark as <br /> "exempt"underground tanks. It must also include all transfer stations <br /> and connecting pipes,including intra-facility gathering lines. <br /> Immediately update the facility diagram to include all of the required <br /> information.Submit a legible copy of the updated facility diagram to <br /> the EHD for review. <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: APSA <br /> Violation Source: CERS <br /> Site ID: 273240 <br /> Site Name: MAXIM CRANE WORKS <br /> Violation Date: 05-27-2016 <br /> Citation: HSC 6.67 25270.4.5(a)-California Health and Safety Code,Chapter <br /> 6.67,Section(s)25270.4.5(a) <br /> Violation Description: Failure to perform periodic integrity and leak testing of buried <br /> piping. <br /> Violation Notes: Returned to compliance on 05/21/2019. No integrity test results were <br /> available for the buried used oil piping.According to the SPCC Plan, <br /> the piping was modified in 2007 to provide cathodic protection. Buried <br /> piping shall be tested for integrity and leaks at the time of <br /> installation,modification,construction,relocation,or replacement. <br /> Immediately perform integrity and leak testing of this piping and <br /> ensure that piping is tested when required,or provide equivalence as <br /> allowed by CFR 112.7(a)(2). <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: APSA <br /> Violation Source: CERS <br /> Site ID: 273240 <br /> Site Name: MAXIM CRANE WORKS <br /> Violation Date: 07-01-2009 <br /> Citation: 2014-0057-DWQ-Industrial General Permit <br /> Violation Description: SW-Deficient BMP Implementation <br /> Violation Notes: Failure to maintain stormwater BMPs. Exceedance of EPA benchmarks. <br /> Violation Division: Water Boards <br /> Violation Program: INDSTW <br /> Violation Source: SMARTS <br /> Site ID: 273240 <br /> Site Name: MAXIM CRANE WORKS <br /> Violation Date: 07-01-2014 <br /> Citation: 2014-0057-DWQ-Industrial General Permit <br /> Violation Description: SW-Late Report <br /> Violation Notes: Failure to submit 2013/2014 annual report. <br /> TC6327721.2s Page 369 <br />