My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1532
>
2300 - Underground Storage Tank Program
>
PR0231522
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2021 11:09:40 AM
Creation date
5/3/2021 8:47:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231522
PE
2361
FACILITY_ID
FA0004051
FACILITY_NAME
UPS - Stockton
STREET_NUMBER
1532
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1532 N Broadway Ave
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:B7E23BC6-4CD0-4176-91DB-916E1DCCCAC4 <br /> June 18, 2021 <br /> San Juaquin County <br /> Environmental Health Department <br /> 1868 E. Hazelton Avenue <br /> Stockton, CA 95205 <br /> RE: UPS Stockton Facility 1532 N Broadway Ave, Stockton, CA 95205— UST Monitoring Annual <br /> Certification Exceptions. <br /> Dear Ms. Baker, <br /> This letter is pertaining to the annual UST monitoring system certification conducted May 20, <br /> 2021 at our Stockton facility, and in response to the four violations cited during the inspection. <br /> Below are excerpts of the violations taken from the county's inspection report(Attachment A). <br /> Item# 115 <br /> CCR 2638(c), 2638(d) Failure to submit "Monitoring System Certification Form" within <br /> 30 days of completion of the test. <br /> OBSERVATION:Annual monitoring system certification, leak detector testing, and spill <br /> container testing was performed on 5/20/2020 and a test report was submitted on <br /> 12/30/2020, seven months late. <br /> REGULATION GUIDANCE.A copy of the test report must be submitted within 30 days of the <br /> tests. <br /> CORRECTIVE ACTION. Take all necessary precautions to ensure testing and submittal of <br /> test reports are performed in a timely manner. <br /> UPS respectfully disputes this finding and request it be rescinded as an email was sent to your <br /> office on 6/19/20. See Attachment B which contained the certification report conducted on <br /> 5/20/20, sent by our testing contractor RL Stevens' technician Dave Pereira. Report submittal via <br /> email is and has always been our primary means of submittal of the report within 30 days of <br /> testing. The inclusion of the report in our annual HMBP submittal through CERS that was done <br /> on 12/30/20 is not our means of fulfilling that requirement. <br />
The URL can be used to link to this page
Your browser does not support the video tag.