Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for SINCLAIR/DINO MART as of July 19 , 2021 . <br /> Open violations from May 26 , 2021 inspection <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) . <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #210 - Failure to provide initial training , train every 12 months , and have a trained employee <br /> present. <br /> OBSERVATION The designated operator employee training for all employees was not not current. The current <br /> training records on site were dated 2017 . <br /> REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the <br /> individual performs the duties of a facility employees . The training shall include , but is not limited to : <br /> 1 . Operation of the UST system in a manner consistent with the facility' s best management practices <br /> 2 . Employee' s role with regard to monitoring equipment as specified in the facility' s monitoring plan <br /> 3 . Employee' s role with regard to spills and overfills as specified in the facility' s response plan <br /> 4 . Name of the contact person (s) for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> evaluating knowledge for responding to emergencies , leak detection , monitoring alarms , spills and overfills . At least <br /> one of the facility employees present during operating hours shall have current training . <br /> CORRECTIVE ACTION : Ensure that employees have been trained by the designated operator, maintain the list on <br /> site , and submit a copy of the training records to the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #306 - Failure to remove , analyze , and properly dispose of water in secondary containment <br /> ( pre-Jul 2003 ) . <br /> OBSERVATION Liquid was observed in the 87 main fill sump and 91 fill sump. <br /> REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration , it <br /> must be removed and disposed of properly . <br /> CORRECTIVE ACTION : The service technician removed approximately 5 gallons of liquid from the 87 main fill <br /> sump and 5 gallons of liquid from the 91 fill sump. Ensure that all sumps and annular spaces are maintained free of <br /> liquid . <br /> Page 5 of 8 <br />