My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2022 8:36:43 AM
Creation date
5/20/2021 11:26:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
SINCLAIR/DINO MART
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for SINCLAIR/DINO MART as of July 19, 2021. <br /> Open violations from May 26, 2021 inspection <br /> q1 This violation was corrected ❑ This violation will be corrected by (date): <br /> ❑ Supporting documents included I <br /> Describe actions taken or will betaken to correct violation: <br /> 0,1+- 'i"��n�� 7 DVS -'S t-P C �l✓� �I�V ,°"nt <br /> Violation#319-Failure to comply with overfill prevention equipment requirements. <br /> OBSERVATION Overfill prevention testing has not been conducted. <br /> REGULATION GUIDANCE: Overfill prevention equipment inspections were required to be conducted by October <br /> 13, 2018, and every 36 months thereafter, and within 30 days of completion of a repair. <br /> CORRECTIVE ACTION: Immediately schedule this testing and provide 48 hours notification to the EHD. Ensure all <br /> future testing is conducted within required time frames. <br /> ❑ This violation was corrected PLThis violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: -1�p <br /> /�I.L C� inn P.. lAl t <br /> Open violations from May 26, 2020 inspection <br /> Violation#203-Failure to maintain monitoring, maintenance,and follow up action records. <br /> OBSERVATION Maintenance and monitoring records for the last three years were not found on site. <br /> -The 2019 Monitoring system certification test results were not found on siste. <br /> -The 2018 Monitoring system certification test results were not found on site. <br /> -The 2017 monitoring system certification test results were not found on site. <br /> -The current Secondary containment test results were not found n site. <br /> -The current Overfill prevention test results were not found on site. <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance <br /> records; (3) results of any visual observations; (4)results of sample analysis performed a lab or in the field; (6)logs <br /> of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br /> inventory readings and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the <br /> last three years on site and submit copies to the EHD. <br /> I <br /> Page 6 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.