SR0083481
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BOWMAN
>
76
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0083481
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2021 11:48:43 AM
Creation date
5/20/2021 1:07:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0083481
PE
4201
STREET_NUMBER
76
Direction
W
STREET_NAME
BOWMAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19326019
ENTERED_DATE
3/30/2021 12:00:00 AM
SITE_LOCATION
76 W BOWMAN RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
EHIntern
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONSITE WASTEWATER TREATMENT SYSTEM DESIGN: <br /> OPERATIONAL COMTONENTS AND PARAMETERS TO MITIGATE NITRATE LOADING <br /> The following is an overview describing the operational design: The OWTS design begins with a <br /> 2,000 gallon P&L Concrete, Inc. standard precast septic tank that is set with the inlet invert <br /> elevation 13 inches below existing grade(top of tank at grade). Potential surge flow is easily <br /> accommodated with this tank size given that the modular home is a small, three bedroom structure <br /> (§7.1.2). The tank is to be situated in line with the influent tightline. <br /> In the second compartment of the septic tank, an Orenco Universal BioTube Pump Vault is to be <br /> installed. Within the screened pump vault is a duplex pump system. The pumps will alternate <br /> operations and will be set to time dosing through the Orenco MVP Duplex Panel. Top float= <br /> High Level Alarm,with lag pump enabled. No. 2 float over-ride timer on. Bottom float=Timer <br /> on and off. Timer starts with off time count down. Off time is 60 min; on time is 38 seconds. <br /> Over-ride timer off time is 30 min and on time is 38 seconds. <br /> Screened effluent is pressurized through a 1.0" transport line; then through a 1" to 4" PVC <br /> reducer; then into a 4" tightline manifold as illustrated on the design plans. As the effluent <br /> expands from 1" to 4"delivery, the energy of the pumped effluent decreases and allows the <br /> effluent to rise within the manifold with enough speed and volume for the effluent to seek its own <br /> level throughout the length of the manifold. Effluent then flows relatively equally into each of the <br /> three 22' elbows,then into the perforated piping. <br /> For this locale,the SJC OWTS Standards require 240 lineal ft of leachline (LFLL), and 960 sf of <br /> infiltrative surface area. Three, 80 ft long (240 LFLL)perforated piping will "T" connect to the <br /> 22°elbow from the manifold, as illustrated. The three 4" dia. perforated laterals are to be lasered- <br /> in level and capped at the ends. The 100%reserve area is also illustrated adjacent to the west of <br /> the three leachlines. <br /> The floor of the 3 leachline trenches shall be set at 24" below final grade. This will maintain the <br /> required 8' separation distance (due to natural rapid permeability mitigation) between the soil- <br /> effluent interface and the highest anticipated depth to groundwater: 12" drain rock under laterals+ <br /> 4" drain rock for ht. of perforated piping+2" drain rock above laterals+ 6" native excavated soil <br /> cover over each leachline trench(§9.4)=24". 120" (10 ft)=highest anticipated depth to <br /> groundwater minus 24" = 96" (8.0' separation distance). Filter fabric is to be laid over the drain <br /> rock before 6" native soil cover backfill to surrounding grade. <br /> The Attachments to this Report include the following Technical Data Sheets(T.D.S.) in Appendix D: <br /> 1. MVP-DAX DM Setting Instructions for time dosing. <br /> 2. Splice Box <br /> 3. Float Switch Assemblies T.D.S. <br /> 4. PF Series 4" Submersible Effluent Duplex Pump System T.D.S. <br /> 5. High Head H=V(W/Check Valve) <br /> 6. Universal Biotube Pump Vault T.D.S. <br /> Page-3- <br /> Chesney Consulting <br />