Laserfiche WebLink
Map ID <br />Direction <br />Distance <br />Elevation <br />MAP FINDINGS <br />Site <br />EDR ID Number <br />Database(s) EPA ID Number <br />HUSKY CRANE INC (Continued) 1000273351 <br />Site ID: <br />273240 <br />Site Name: <br />MAXIM CRANE WORKS <br />Violation Date: <br />07-22-2020 <br />Citation: <br />HSC 6.5 25201 - California Health and Safety Code, Chapter 6.5, <br />Section(s) 25201 <br />Violation Description: <br />Failure to obtain a permit or grant of interim status after generator <br />has accumulated hazardous waste on-site for longer than 90 days. <br />Violation Notes: <br />OBSERVATION: The following hazardous waste containers were found <br />on-site with an accumulation start date of greater than 90 days or no <br />accumulation start date: -1 black metal 55 gallon drum of oily solids <br />was observed in the hazardous waste storage area with an accumulation <br />start date of 4/1/2020. -1 black metal 55 gallon drum of oily solids <br />was observed in the hazardous waste storage area with an accumulation <br />start date of 3/8/2020. -1 black metal 55 gallon drum of oily solids <br />was observed in the hazardous waste storage area with an accumulation <br />start date of 4/17/2020. -the 275 gallon used anti -freeze tank was <br />observed without an accumulation start date. The last disposal record <br />for used anti -freeze was dated 11/7/2019. REGULATION GUIDANCE: (a) a <br />generator may accumulate hazardous waste on-site for 90 days or less <br />(b) The beginning of the 90 day period is determined as follows: (1) <br />if the generator does not generate more than 100 kilograms of <br />hazardous waste or <br />Violation Division: <br />San Joaquin County Environmental Health <br />Violation Program: <br />HW <br />Violation Source: <br />CERS <br />Site ID: <br />273240 <br />Site Name: <br />MAXIM CRANE WORKS <br />Violation Date: <br />07-22-2020 <br />Citation: <br />22 CCR 15 66265.192(k) - California Code of Regulations, Title 22, <br />Chapter 15, Section(s) 66265.192(k) <br />Violation Description: <br />Failure to include all required information in the tank system <br />assessment. <br />Violation Notes: <br />OBSERVATION: This facility has hazardous waste tanks with incomplete <br />tank assessments. -the tank drawing for the 275 gallon used <br />anti -freeze tank and the 1,000 gallon used oil tank was missing the <br />dimensions. -the tank assessment for the 275 gallon used anti -freeze <br />tank stated tank does not comply with CCR Section 66265.192 (k) <br />REGULATION GUIDANCE: Title 22 California Code of Regulations section <br />66265.192(a) Owners or operators of new tank systems or components <br />shall ensure that the foundation, structural support, seams, <br />connections, and pressure controls (if applicable) are adequately <br />designed and that the tank system has sufficient structural strength, <br />compatibility with the waste(s) to be transferred, stored or treated, <br />and corrosion protection so that it will not collapse, rupture, or <br />fail. The owner or operator shall obtain a written assessment reviewed <br />and certified by an independent, qualified, professional engineer, <br />registered in California in accordance with sectio <br />Violation Division: <br />San Joaquin County Environmental Health <br />Violation Program: <br />HW <br />Violation Source: <br />CERS <br />Site ID: <br />273240 <br />Site Name: <br />MAXIM CRANE WORKS <br />Violation Date: <br />05-27-2016 <br />Citation: <br />HSC 6.5 Multiple - California Health and Safety Code, Chapter 6.5, <br />Section(s) Multiple <br />TC6327721.2s Page 374 <br />