AIR DEVICE SCHEDULE <br /> FRAME U) <br /> MARK SERVICE MANUFACTURER MODEL STYLE FACE SIZE NECK SIZE TYPE NOTES z <br /> CD1 SUPPLY METAL*AIRE V4004D-1 ALUMINUM DOUBLE DEFLECTION WALL 20 X 8 18 X 6 SURFACE A, B, C, D <br /> SUPPLY GRILLE Y z <br /> ROOFTOP UNIT SCHEDULE CD2 SUPPLY METAL*AIRF 700-6 AL ROUND NECK CEILING DIFFUSER 24 X 24 PER PLAN LAY-IN A, B, C, D w � <br /> CD3 SUPPLY METAL*AIRF 700-1 AL ROUND NECK CEILING DIFFUSER 12 X 12 PER PLAN SURFACE A, B, C, D = w <br /> COOLING CAPACITY @ HEATING CAPACITY @ CD4 SUPPLY METAL*AIRE V4004D-1 ALUMINUM DOUBLE DEFLECTION WALL 14 X 8 12 X 6 SURFACE A, B, C, D z O o <br /> SUPPLY FAN 95°F(MBH) 22°F ELECTRICAL DATA SUPPLY GRILLE U) <br /> NOMINAL E.S.P. OSA GAS INPUT SUPPLY <br /> RGI RETURN METAL*AIRE CC5-6 EGGCRATE CEILING RETURN 24 X 24 22 X 22 LAY-IN A, B, C, D w <br /> GRILLE Lu <br /> MARK MANUFACTURER MODEL TONS CFM (IN. WC) (CFM) TOTAL SENSIBLE SEERIEER (MBH) TEMP (°F) V/PH MCA MOCP WEIGHT <br /> RG2 RETURN METAL*AIRE CC5-1 EGGCRATE SIDEWALL RETURN 26X 14 24 X 12 SURFACE A, C, DCw <br /> RTU-1 CARRIER 48HC-D08 7.5 3000 0.75" 300 90 72.2 12 90/125 84.1/93.4 208/3 41 50 1173 GRILLE 4 co Q <br /> RTU-2 CARRIER 48HC-A06 5 2000 0.5" 200 60 48 15.2 82 92.2 208/3 29 40 799 N <br /> NOTES (ALL NEW UNITS): GENERAL INFORMATION (ALL DEVICES): Q 4 <br /> A. PROVIDE FILTER WITH EACH UNIT. 1. ALL DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE. <br /> B. PROVIDE WITH FULLY MODULATING ECONOMIZER WITH ENTHALPY CONTROL. 2. ALL AIR DEVICES SHALL BE PROVIDED BY 7-ELEVEN AND INSTALLED BY THE CONTRACTOR. FOR <br /> C. SMOKE DETECTORS TO BE PROVIDED AND INSTALLED BY CARRIER. LOCATE AS SHOWN ON PLAN. ADDITIONAL INFORMATION CONTACT CHAD LITERSKY(214) 350-6871 EXT. 2140 WITH BARTOS ❑ ❑ ❑ ❑ <br /> D. CONDENSATE TRAP SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. PROVIDE TRAP OF ADEQUATE DEPTH TO INDUSTRIES. This document, the ideas and <br /> PREVENT STATIC FROM OVERCOMING TRAP SEAL. ROUTE TO NEAREST APPROVED RECEPTOR. designs incorporated herein, are <br /> E. PROVIDE WITH STANDARD ROOF CURB AND ACCESSORIES. NOTES: solely the property of VAI and is <br /> F. OUTDOOR AMBIENT DESIGN TEMPERATURE 95 DEG.F. A. DIFFUSER NECK SIZE SHALL BE SAME AS BRANCH DUCT SIZE UNLESS NOTED not to be used, in whole or in <br /> G. SET FAN OPERATION TO CONTINUOUS. OTHERWISE. dupart for any project or <br /> plication, without written <br /> H. TEMPERATURE SET POINTS DURING OCCUPIED HOURS; HEATING MODE: 66°F - COOLING MODE: 75°F. B. DAMPER AT TAKEOFF TO DEVICE. authorization. <br /> I. PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR, FOR ADDITIONAL INFORMATION CONTACT NATIONAL ACCOUNT C. STANDARD OFF-WHITE FINISH. © COPYRIGHT 2019 <br /> REPRESENTATIVE BOBBY KIMBRELL (512) 267-3366, BOBBY.KIMBRELL@CARRIER.UTC.COM. D. PROVIDE NECK FOR DUCT CONNECTION. ❑ ❑ ❑ ❑ <br /> J. CONTACT AUTOMATED LOGIC (ALC)AT(866) 390-4275 FOR BUILDING ENERGY MANAGEMENT SYSTEM. <br /> K. PROVIDE WITH 1/0 FLEX CONTROL MODULE. LOUVER SCHEDULE U Q C) � Ln <br /> L. PROVIDE WITH CONDENSER COIL HAIL GUARD (LOUVERED DESIGN). <br /> M. PROVIDE WITH PRE-COATED OUTDOOR COILS WITHIN A 5 MILE RADIUS OF ANY SALT OR BRACKISH WATER. MARK QUANTITY MANUFACTURER MODEL I SIZE FREE AREA CFM E.S.P. (IN. WC) VELOCITY(FPM) <br /> LV-1 2 GREENHECK ESJ-401 42"X 24" 3.18 SQ. FT. 2500 0.1" 787 uj < '1 cN cN,-) <br /> EXHAUST FAN SCHEDULE NOTES: U � <br /> A. PROVIDE WITH SLEEVE AND BR-30 BAROMETRIC RELIEF DAMPER. U 'Z� 'd p U-)) Ln <br /> MARK QUANTITY MANUFACTURER MODEL CFM E.S.P. (IN. WC) V/Ph WATTS CONTROL B. LOUVER SHALL BE PRE-FINISHED DARK BRONZE (KYNAR 70% 3-COAT- CFT5835-C) IN COLOR. (� `n `n <br /> C. TO BE PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR. FOR ADDITIONAL �i y ca aj <br /> EF-1 2 GREENHECK SP-B150 100 0.25" 120/1 129 1 LIGHT SWITCH INFORMATION CONTACT CHAD LITERKSY(214) 350-6871 EXT. 2140 WITH BARTOS U 4..( +� U c� <br /> NOTES: INDUSTRIES. p �+ <br /> A. PROVIDE GRAVITY BACKDRAFT DAMPER. <br /> B. PROVIDE SPRING VIBRATION ISOLATORS FOR HANGER ROD SUPPORTS. i�-I -r-4Ln U <br /> C. TO BE PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR. FOR ADDITIONAL O N <br /> U w <br /> INFORMATION CONTACT CHAD LITERKSY(214) 350-6871 EXT. 2140 WITH BARTOSO op <br /> INDUSTRIES. PROVIDE 1X1/8 STEEL STRAP AT ALL CORNERS & NOT TO ca.� <br /> EXCEED 4'-0" O/C EACH ANCHORED W/4 #12 BY 3"LONG GALV. <br /> SCREWS TO ROOF CURB & W/4 #12 BY 1"LONG SCREWS TO 4� <br /> 1. DETAIL ELIMINATES PITCH RTU. THROUGH BOLT RTU TO CURB WITH 3/8"BOLTS, ONE AT <br /> EACH CORNER. <br /> POCKETS FOR PIPING PENETRATIONS SHEET METAL HOOD; COORD. <br /> FACTORY CURB: NRCA APPROVED, 16 GAUGE, SQUARE U � <br /> THROUGH THE ROOF. PITCH POCKET WITH MECH SHEETS FOR REQ'D WITHIN 1/8"ON DIAGONAL MEASUREMENT, WITH A MINIMUM <br /> INSTALLATIONS ARE PROHIBITED. NUMBER OF LINES SETS AND OF 8"ABOVE TOP OF ROOF, WHEN IN DOUBT PROVIDE 18" <br /> 2. ATTACHED TREATED WOOD SIZE OF OPENING REQ'D. OR GREATER CURB. <br /> NAILER TO DECK WITH SUITABLE SHEET METAL OR FLEX TUBE (E) ROOF DECK% 3/4"MI NOTE: FOR T-BAR GRILLE <br /> GASKET AND SILICONE <br /> FASTNER AS REQ'D PER LOCAL AHJ. COLLAR. PROVIDE CONT. RESTRAINT SEE DET. D/M2.0. SEALING <br /> BEAD OF SEALANT AT COLLAR UPPORT W/4 1-1/2"x 24 GA. S.M. PRESSURE-TREATED WOOD NAILER <br /> 3. PROVIDE MIN 2"BETWEEN ) <br /> PIPES AND 4"MIN CLEARANCE SHEET MTL FLASHING RECIVER STRAPS. SECURE TO PLENUM STRIP <br /> FROM PIPE TO TOP OF CURB. WITH GASKETED FASTENERS @ WITH#10 S.M. SCREWAND TO COUNTER FLASHING STRIP <br /> Z MIN 18"O.C. AROUND PERIMETER BRANCH SIZE STRUCTURE WITH 1/4"0 x 2" <br /> � OF PIPE PORTAL; PROVIDE +2"BY NECK 6rr CONCRETE ANCHOR. (TYP.) 8„ 1"RIGID INSULATION ❑ ❑ ❑ ❑ <br /> SINGLE PLY ROOFING PROPER FASTENING SCHEDULE SIZE +2'. FLEXIBLE S.A. DUCT. SEE PLAN <br /> MEMBRANE OVER LAP AS REQ'D PER LOCAL AHJ. FOR CONTINUATION. MIN. 3"CANT STRIP <br /> FLASHING AS REQ'D PER ROOFING MEMBRANE <br /> ROOFING MEMBRANE z REMOVABLE COUNTER FLASHING OPPOSED BLADE DUCT COLLAR / \ c ` 6�/�Y��;� <br /> SPECIFICATIONS aT_ OVER FASTNERS @ 8"O.C. DAMPER (IF NOTED _ _ _ , 00 z M z <br /> J w PLANS) 1"ACOUSTIC LINED SUPPLYAIR _-', _ w <br /> U_= ROOFING MEMBRANE TO EXTEND PLENUM. <br /> o MIN OF 2"ABOVE CANT <br /> SPECIFIED DIFFUSE FINISH CEILING. SEE ARCH. !? �� J <br /> DRAWINGS. �\�; `;k , ,i ``;` �' < w <br /> THERMAL SHEET METAL TAPER. WRAPSIPS ROOF <br /> INSULATION W/INSULATION. (EXCEPT SHEET <br /> EXHAUST). META El L1 El L1T END OF RUN ONL DUCT PROVIDE 4X4X1/4"ANGLES WELDED <br /> BETWEEN BAR JOIST FOR THROUGH BOLTING <br /> WOOD CANT AS REQ'D TO SHEET METAL OR FLEXIBLE STRUCTURAL ROOF CURB. USE 3/8" GALV. STEEL BOLTS <br /> ROOF DEC BRACE CURB DUCT. STEEL JOIST SPACED 1 BOLT AT EACH CORNER AND 1 <br /> INSULATE VOID AS <br /> BOLT AT MID POINT OR 2 FT 0.C. MAX. <br /> REQ'D TO ❑ <br /> PREVENT CONDENSATION PED <br /> J <br /> d <br /> DETAIL @ PIPE PORTAL E TYPICAL S.A. DEVICE—BRANCH DUCT DETAIL C ROOF CURB DETAIL ,q <br /> SCALE: NONE �2_ SCALE: NONE 2.O SCALE: N.T.S. �M2J-O <br /> VERTICAL 114"X2"SAMMY o <br /> 3/8"ALL THREAD ANCHOR, CLIP <br /> TYP OF 2 rn <br /> NOTE: USE THIS DETAIL FOR SUPPLY& RETURN GRILLES INA T-BAR CEILING. z Q <br /> SIPS ROOF (W) z <br /> 0 O <br /> REF. PLANS FOR U <br /> ~ _ _ GRILLE L RUNOUT SIZES SPIN-IN FITTINGS - <br /> W/SCOOPS ARE z <br /> 1/8" S1 S1 M ^ O <br /> PLAN VIEW 1"x1"x3"x20 GA. O O NOT ACCEPTABLE I..1..1 <br /> CLIP. Q �� 1-- <br /> PLAN <br /> U) <br /> 3/8 HEX NUT, TYPT-BAR FRAME P� P Z U J <br /> TYP. OF 2/GRILLE <br /> O <br /> COSH-A-CLAMP FIRMLY 3/8"ALL q �1/8" WASHER UJcn W <br /> CLAMPED TO PIPE, TYP----_, THREAD ROD w } � <br /> 3/8"HEX01j. alt. �2) #8x1"S.M. SCREW. U) > Q 0 <br /> NUT, TYP = o t = (EACH CLIP) <br /> W O UJ w z <br /> 1/4" TURNED UP LIP FLEXIBLE DUCT FOR Q <br /> 3/8"CHANNEL NUT 1 5/8"x 1 5/8" T__ OF GRILLE. FINAL CONNECTION ONLY: <br /> WITH SPRING GALVANIZED UNISTRUT _ 6'-0"MAX LENGTH. Q J <br /> FACE OF GRILLE T BAR RAIL L = W/4, 4"MIN *45° LEAD IN 2 <br /> QROFESSIp <br /> PIPING INSULATION �o IN <br /> O'�! LL1 <br /> AS PER SPECS. W 3 ' o <br /> REFRIGERANT LINE SUPPORT F GRILLE RESTRAINT DETAIL p BRANCH DUCT FITTING g ! co � <br /> SCALE: NONE �2_ SCALE: NONE �2. SCALE: N.T.S. 2.O r:Ert. s- -cost ❑ ❑ ❑ ❑ <br /> 1!'9T` <br /> F 0CAL�FO ISSUE DATE: 7-30-19 <br /> REV. DATE: 12-20-1q <br /> LAWREN C E PROJECT NO.: 18008.2 <br /> ENGINEERING GROUP DRAWN BY: NL <br /> � M-2.0 - SCHEDULES AND DETAILS 7084 N.Maple Ave.,Suite 101 Fresno,CA 93720 <br /> (559) 431-0101 19368 FAX(559)431-1362 SHEET: <br /> M -2 . 0 <br />