Control Panel CP- 1 <br /> U) <br /> D02 D01 Z <br /> SIGNAGE/CANOPY LIGHTS PARKING LIGHTS Q <br /> 2 <br /> Ltg. Contactor Ltg. Contactor U <br /> By Elec, Typ. By Elec, Typ. <br /> Y Z <br /> O O Lu J <br /> U <br /> Z O z <br /> TIMED <br /> Q O O <br /> OVERRIDE@ O <br /> BUTTON C C @ E: °� <br /> 10 POR"f_ wo � <br /> 000 w <br /> Q <br /> ;1ee� CONTRACTOR SCOPE OF WORK <br /> o w <br /> CCNEROLMODULE • SENSOR LOCATIONS TO BE APPROVED BY 7/11 AND ALC PRIOR TO CV N <br /> N H N H O mO FINAL INSTALLATION. PROVIDE PICTURE OF PROPOSED LOCATION v C' Q <br /> Locate next to computer 120VAC V100 120VAC V100 rvCi CE n1 co <br /> By Elec By Elec �'� AND SEND TO ALC FOR APPROVAL. `°' <br /> ' 0 MECHANICAL CONTRACTOR TO MOUNT/INSTALL SENSOR AND <br /> 'M­ <br /> SENSOR_ - SENSOR WIRING. Q 4 <br /> • MECHANICAL CONTRACTOR TO INSTALL ALL END DEVICES SHIPPED <br /> LOOSE WITH AIR HANDLING EQUIPMENT. THIS MAY INCLUDE J J J J <br /> CURRENT TRANSFORMERS, OUTDOOR AIR SENSORS, AND MIXED AIR KEYNOTES <br /> SENSORS. WIRE END DEVICES TO 10 FLEX CONTROLLER. This document, the ideas and <br /> @ @ ❑ COORDINATE LOCATION WITH MECHANICAL. designs incorporated herein, are <br /> @ @ 1. COORDINATE ROUTING AND FINAL LOCATIONS OF COMMUNICATIONS solely the property of VAI and is <br /> AND CONTROLS WIRING BETWEEN MECHANICAL, ELECTRICAL AND REFER TO 4/EMS 1.0 FOR TL O, HUMIDITY SENSOR not to be used, in whole or in <br /> @ @ REFRIGERATION SYSTEM LIGHTING SYSTEM _ "_ AND LIGHTING CONTACTOR WIRING DETAIL. REFER <br /> CONTROLLER CONTROLLER - LOW VOLTAGE CONTRACTOR. part for any project or <br /> TO 1/EMS1.0 FOR SMART CONTROLLER AND duplication, without written <br /> Smart Controller 2. ALL EXTERIOR AND BELOW CEILING POWER, CONTROLS AND EVAPORATOR WIRING DETAIL. p <br /> Q ® ® Rao® °d IN '• COMMUNICATIONS WIRING TO BE ROUTED IN CONDUIT. INSTALL authorization. <br /> CMnet ".,. ® � _�❑ z4VAC T1 lzovnc CONDUIT FOR INTERIOR CONTROL AND COMMUNICATION WIRING LIGHTING OVERRIDE SWITCH. INSTALL ON BACK © COPYRIGHT 2019 <br /> tl •• Powe ns " a WALL ABOVE WORK SURFACE OF WORKSTATION <br /> a ONLY IF REQUIRED BY AHJ. LOCATED IN BACK ROOM. ❑ ❑ ❑ ❑3. BELDEN CABLE NUMBERS ARE SHOWN ON WIRING DIAGRAM FOR <br /> ® ° o 0 0 ,= CABLE REQUIREMENTS SHIELDING, PLENUM RATING, AWG, ETC. • <br /> " CONTRACTOR TO PROVIDE BELDEN CABLE AS SHOWN, OR CONTACT V O N 71- It- <br /> BEST <br /> BEST WIRE AND CABLE FOR APPROVED ALTERNATE CABLE. SYMBOL DESCRIPTION F■ �' <br /> ZNzo <br /> CONTACT PATRICK HAMACK AT BEST WIRE AND CABLE(972) 658-9986 ,-, G1 <br /> 0 R a;,c a s's 0 @ @ �DNPROLLCt ®" FOR QUESTIONS ABOUT CABLE REQUIREMENTS. t/j cN CN <br /> TL LIGHTING OVERRIDE SWITCH <br /> e m 's m "o 's°^m @ @ roEVAP nnnsrex eAcnet 4. PROVIDE ALL FIELD WIRING BETWEEN HVAC AND REFRIGERATION 3-a � <br /> TLO INPUT 1 I ' I CONIROLBOARD S TEMPERATURE SENSOR U Ct <br /> " " MSTPRO,d SPARE @ @ EQUIPMENT AS SHOWN IN 3/EMS1.0 -d <br /> a a O to Ln <br /> 0 "' AUTOIVIATEDIAGIC® mPMeF� 5. INSTALL BACK-BOXES WITH CONDUIT STUB UP FOR COMBO SPACE/ S/H/C COMBO SPACE/HUMIDITY/CO2 �.I" t+, L1 rr� <br /> m Na o R P O R ATI o w o HUMIDITY/CO2 SENSOR. DEVICES TO BE PROVIDED BY CARRIER SENSOR '� U <br /> • .. .. <br /> OFF ZN220 oo-0 o AND AUTOMATED LOGIC CORPORATION(ALC). 4� <br /> ONra, U a ------- EC ------- PROVIDED BY ELECTRICAL CONTRACTOR U w <br /> D1-3 0 6. PROVIDE FINAL INSTALLATION AND CONNECTION OF CONTROL <br /> EXT LIGHTING �+ O <br /> 0 J11 ��� WIRING TO: LIGHTING CONTROL SYSTEM INCLUDING OVERRIDE U O <br /> 0 L,9111 ort EXT LIGHTING TRANSFORMER TRANSFORMER MC ------- PROVIDED BY MECHANICAL CONTRACTOR.11 20V SWITCH, HVAC AND REFRIGERATION EQUIPMENT, COMBO SPACE/ -1DOVA 40VA � (/) <br /> m BACnet° B05 HUMIDITY/CO2 SENSOR, AND EMS SYSTEM. 4-4 N <br /> 7. MOUNT AND PROVIDE POWER TO THE MAIN PANEL. —EMS PROVIDED BY EMS CONTRACTOR O U w <br /> 8. ESTABLISH COMMUNICATION LINK BETWEEN THE MAIN PANEL AND <br /> BUILDING ETHERNET SWITCH. <br /> 9. CONTACT THE EMS SYSTEM MANUFACTURER A T(866) 390-4275 AND <br /> PROVIDE STARTUP OF MAIN PANEL, LIGHTING CONTROLS, HVAC AND <br /> LIGHTING CONTROLS CONNECTION DIAGRAM 5 EMS CONTROL PANEL REFRIGERATION UNITS CAT-5 EMS ETHERNET s� <br /> PORT 22 4� <br /> SCALE: N.T.S. MIS 1. SCALE: N.T.S. MS 1 EMS <br /> EVAP 1 EVAP 1 EMS MAIN 7-11 ROUTER <br /> MASTER EMS MASTER PANEL <br /> SYSTEM 2 SYSTEM 3 <br /> fit;,Un n r.~22 AWG BELDEN#I 269A MS <br /> %,d <br /> LIGHTING <br /> CONTACTOR <br /> EVAP 1 BELDEN#6300FE <br /> ---- MASTER EMS <br /> SYSTEM 1 <br /> /' W <br /> > tf) z <br /> MC Qom` � ? wl'3 <br /> w II^i7 i 0 <br /> Q LU <br /> EVAP 2 W <br /> 13AC114#l■ >w�—� `' SLAVE <br /> OW 3kW � � � 5-remOR SYSTEM 1 PLAN FOR IS FOR <br /> EQUIPMENT LOCATIONS. <br /> 1c0tmt +�ra�t+r� 4 ; ❑ ❑ ❑ ❑ <br /> Ong <br /> r <br /> MC <br /> UJ-12 + 4 a itF BELDEN#1269A <br /> I MC-- RTU-2 <br /> �■ p°■' r,�1gq. n <br /> I11£1 EVAP 3 <br /> ■■ � �l41 � f r <br /> _ S/H/C MC ------------------------------- ------ RTU-1 <br /> 4n- �{' 1 • ; SLAVE - ❑ <br /> SYSTEM 1 <br /> I$r <br /> VL <br /> BELDEN#6541 UE MC <br /> W46' t � j BELDEN#6541 UE <br /> i f ■ <br /> lot <br /> MIR E <br /> ■ :Pr Fil <br /> * �4 <br /> IL AMPw40&s AUK G) ❑ ❑ ❑ ❑ <br /> I!R 9■r 0 # I O <br /> BEACON II I hFT W� ADZ T .1, LIGHTING N <br /> SMART I :5 Ls ".* h * TLO ❑3 rn <br /> CONTROLLER I SYSTEM#2 SYSTEM#3 A04z ■ Q <br /> MULTI#1 MULTI#2 z <br /> U <br /> MASTER MASTER Fan VF0 IBAC rr1 �R �. 'I Z <br /> I +.a�� o•r �� � � Q <br /> Ifller�aCe <br /> MULTI IN MULTI OUT MULTI IN MULTI OUT MULTI IN MULTI OUT MULTI IN MULTI OUT S � y `. Q <br /> $I Z LL <br /> ' per Z <br /> ovyw ■. <br /> .Ir.a M O <br /> SYSTEM#1 + I� L.I.J Z Y <br /> MASTER SLAVE-1 SLAVE-2To <br /> id O <br /> MULTI IN MULTI OUT MULTI IN MULTI OUT MULTI IN MULTI OUT TS -'R EMS FIELD WIRING DIAGRAM UJ U) <br /> UJ } <br /> rT=-. AW 11 y SCALE: N.T.S. MSI. <br /> ..e..Fp- in <br /> is 4 R� 94,�t 4 l$f O <br /> LU LL] <br /> TECHNICIAN TO TERMINATE �a A' <br /> BEACON II SMART CONTROLLER i• �_ # �'' Q Z <br /> LAS SHOWN-NO DEVIATIONS!! P#br1F ■�� ! �;� <br /> QROFESSIOk4 O LU <br /> U J <br /> n O4 �F 0- <br /> i <br /> I�ti�l D1 3 � <br /> P%Oft- r` W <br /> 2 <br /> FO. 9- 2021 ❑ ❑ ❑ ❑ <br /> �FOHA N I <br /> F OF CAL\FO ISSUE DATE: 7-30-19 <br /> REV. DATE: 12-20-1cl <br /> REFRIGERATION SYSTEM CONNECTION DIAGRAM 3 RTU CONNECTION DIAGRAM 2 L A W R E N C E PROJECT NO.: 18008.2 <br /> SCALE: N.T.S. MS1. SCALE: N.T.S. MS1. ENGINEERING GROUP DRAWN BY: NL <br /> 1 EMS-1 .0 - EMS PLAN 7084 N.Maple Ave.,Suite 101 Fresno,CA 93720 <br /> (559) 431-0101 19368 FAX(559)431-1362 SHET: <br /> EE <br /> MS- 1 . 0 <br />