Laserfiche WebLink
Ross Robert Truck Repair Used Oil Tank <br /> Interim Assessment and Conditional Certification <br /> September 14, 2021 <br /> AST Integrity Assessment Inspection Checklist (cont.) <br /> Leak Detection Testing <br /> Primary Tank N Visual ❑ Continuous Interstitial Monitor ❑ Manual Monitor ❑ None ❑ Pass ❑ Fail E Not Tested <br /> Secondary Tank N Visual ❑ Continuous Interstitial Monitor ❑ Manual Monitor ❑ None ❑ Pass ❑ Fail E Not Tested <br /> ❑ Pass ❑ Fail E Not Tested <br /> Piping N Visual ❑ Continuous Interstitial Monitor ❑ Manual Monitor ❑ None <br /> Spill Prevention Adequate?(if no,explain) <br /> Spill Bucket ❑ Yes E No If yes,Capacity_Concrete containment provides spill E Yes ❑ No <br /> containment <br /> Venting Operable? <br /> Primary Tank Working Vent ❑ Yes E No Diam:_3"port available ❑ Yes ❑ No E NA <br /> Primary Tank Emergency Vent N Yes ❑ No Diam: 5" N Yes ❑ No ❑ NA <br /> Secondary Tank Working Vent ® Yes ❑ No Diam: 3" N Yes ❑ No ❑ NA <br /> Secondary Tank Emergency Vent ❑ Yes E No Diam: 5"port available ❑ Yes ❑ No N NA <br /> Piping <br /> Primary Piping Material: ❑Steel ❑Fiberglass EOther flexible hose Diameter(in.) F, <br /> Piping Connection Type:EThreaded ❑Welded ❑Flanged ❑ Other <br /> Secondary Containment <br /> Piping: ❑Integral DW Piping E Containment berm ❑Controlled Drain/Sump ❑ None <br /> ❑ Other(description) <br /> Piping Secondary Containment Material ❑ Steel ❑ Fiberglass N Other Concrete Diameter(in.) ❑ None <br /> Grounding/Bonding Adequate?(if no,explain) <br /> ❑ Present E Absent Secure? ❑ Yes ❑ No N Yes ❑ No_ <br /> Foundation Type: N Concrete Slab ❑ Housekeeping Pad ❑ Ringwall ❑ Asphalt ❑ Saddle <br /> ❑ Other <br /> Anchor Bolt Size: in. No.of Bolts: 0 Condition ❑ Secure ❑ Not Secure N Not Bolted Adequate?(if no,explain) <br /> Anchor Bolt Spacing: in. Anchor bolt to slab edge:No anchoring feet on tank ❑ Yes N No_ <br /> Foundation Condition N Good ❑ Fair ❑ Poor ❑ N/A Adequate?(if no,explain) <br /> Spalling? ❑ Yes E No Can Water Drain Away? ❑ Yes N NA N Yes ❑ No <br /> Any Settlement? ❑ Yes N No Cracked? ❑ Yes N No Tank in covered area, not <br /> Exposed Rebar? ❑ Yes ® No Washouts/Voids? ❑ Yes N No exposed to rain <br /> Electrical <br /> Any loose or unprotected wiring? ❑ Yes N No No wiring <br /> Conduits,junction boxes, and other protective equipment sealed as required? ❑ Yes ❑ No _N None <br /> Emergency Shutoff Switch El Yes N No Tested? El Yes El No El Not permitted to test <br /> Corrosion Protection Adequate?(if no,explain) <br /> N Coating ❑ Cathodic Protection ❑ Other ❑ None N Yes ❑ No_ <br /> Coating Condition: Chalking Rating: (8-0,8=no chalking) <br /> Most of coating on tank top no longer present,some areas missing on upper side of tank. <br /> However,tank is located indoors and is not in contact wth soil. <br /> 4 <br />