My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARRISON
>
641
>
2200 - Hazardous Waste Program
>
PR0514497
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 2:40:34 PM
Creation date
6/22/2021 3:53:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0514497
PE
2228
FACILITY_ID
FA0011023
FACILITY_NAME
Ross Roberts Truck Repair Inc
STREET_NUMBER
641
Direction
S
STREET_NAME
HARRISON
STREET_TYPE
St
City
Stockton
Zip
95203
CURRENT_STATUS
01
SITE_LOCATION
641 S Harrison St
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
244
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ross Robert Truck Repair Used Oil Tank <br /> Interim Assessment and Conditional Certification <br /> September 14, 2021 <br /> AST Integrity Assessment Inspection Checklist <br /> Tank Inspector: Nancy Rebholtz Cert#: AST-6710 <br /> Site Name: Ross Roberts Facility Contact: Contact Tel No.: Date: 7/20/2021 <br /> Truck Repair Dan Payne 209-466-56230 <br /> Site Address: Tank Contents: <br /> Street: 641 S. Harrison St City: Stockton Zip:_95206 Waste Oil <br /> Tank Id (if any) Gross Capacity: Yr Installed: Tank Mfg.: Tank Model: <br /> none From dimensions: 300 gal Unknown Containment Solutions Lube Cube <br /> Previous Formal Inspections ®No ❑Yes Date: Type:El Internal El External <br /> Copy of Prior Inspection Available?: ❑Yes ®No <br /> Owner Annual Inspections Review Owner Monthly Inspections Review <br /> Copy of Inspection Available?: ❑Yes NNo Copy of Inspection Available?: El Yes NNo <br /> Operating Inspection Frequency <br /> ❑Annually ❑Monthly ❑Weekly ❑Daily ❑Per Shift Recorded ❑Yes ❑No <br /> Tank Configuration(long. dimen.) Dimensions: Rectangular Tank: L: 60" W: 30" H:_40"_ <br /> ®Horizontal ❑Vertical Secondary Tank: L: 63" W: 36.5" H:_37.5" <br /> Industry Standard(Fabrication&Nameplate Data) <br /> NUL 142 ❑UL 2085 ❑ UL 80 ❑ API 650 ❑ Other ❑Not Determined <br /> Nameplate Shell Thickness: in. Bottom Thickness: in. Deck Thickness: <br /> Dwg's Available? ❑Yes NNo Is Tank inside Building or Covered? Leak Test or Inspection Avail? <br /> Dwg# I ®Yes ❑No ❑Yes MNo If Yes,Date_ <br /> Overall Tank System Condition: ®Good ❑Fair ❑Poor Adequate? (if no, explain) NYes ❑No <br /> Tank <br /> Primary Tank Material MSteel ❑Fiberglass ❑Other Wall Thickness 0.10723" Basis: MUT ❑Spec ❑UL <br /> Secondary Containment <br /> ❑Integral DW Tank El Containment berm Dimensions: El Controlled Drain/Sump ❑None ❑ <br /> Other(description) Tertiary tank containment provided by concrete containment berm,_47"x 235"x a minimum of 8"high <br /> Liquid in Secondary Containment?: ❑Yes MNo If Yes,contents: <br /> Secondary Containment Material MSteel ❑Fiberglass ❑Other ❑None Wall Thickness 0.10568" <br /> Secondary Containment Condition ❑Good ®Fair ❑Poor Holes/cracks? ❑Yes MNo <br /> Degraded integrity? ❑Yes ®No Corrosion? ❑Yes MNo Paint Failure? ®Yes ❑No areas <br /> of tank coatin have been worn or scraped off <br /> ..............................................................g....................................................................................................p............................................................................................................................................................................................................................................ <br /> Secondary Containment Drain Valve ❑Good ❑Fair ❑Poor MNo Valve <br /> Adequate?(if no,explain) <br /> ®Yes ❑No <br /> How is Tank Level Determined? ❑ Electronic ❑Mechanical Tank Gauge Testing—Level Gauge <br /> M Dipstick ❑ Sight Glass ❑ Other No graduated dipstick ❑ Pass ❑ Fail M Not Tested <br /> Level Gauge Operational? ❑ Yes ❑ No M N/A <br /> Testing—High Level Alarm <br /> High Level Alarm ❑ Yes M No If yes, ❑ Audible ❑ Visual ❑ Pass ❑ Fail N Not Tested <br /> Description/Make/Model/Comments: <br /> Overfill Prevention ❑ Present M Absent Testing <br /> ❑ Pass ❑ Fail M Not Tested <br /> Overfill Valve Installed: ❑ Yes M No <br /> High Level Alarm Triggers Shutoff? ❑ Yes M No <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.