Laserfiche WebLink
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAHANT FOOD N FUEL STOP 24323 N HWY 99 ACAMPO Aril 11 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to check and note all required items on the visual inspection reports. The incorrect and <br /> missing information included the following from the inspection reports: <br /> -Section V was filled out by the designated operator and did not include the corrective actions that will be taken by the <br /> owner/operator. <br /> -The owner/operator printed name was left blank. <br /> -The designated operator phone number was left blank. <br /> -The NA answers were not included in section III. <br /> -Tank and line tightness testing information was left blank. <br /> During the visual inspection, the designated operator shall check that all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designated operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> The designated operator failed to document all the alarms from the attached alarm history on the designated operator <br /> inspection reports and failed to check that they were responded to appropriately. The missing alarms include: <br /> -L1 (diesel STP sump)fuel alarms on 2/26/19 and 4/16/18 <br /> -L5 (UDC 13/14)fuel alarms on 2/27/19 and 11/23/19 <br /> During the inspection, the designated operator shall review the alarm history since the previous inspection, check that <br /> each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the report. Ensure that designated operators performing <br /> inspections at this facility are including all of the required information on the reports. <br /> This is a Class II violation. <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> Designated operator inspection reports were found for 2/6/19 and 4/3/19, but none was found for the inspection in <br /> between those dates. Designated operator inspection reports for the previous thirty-six months shall be retained on <br /> site. Locate and ensure that copies of the previous thirty-six months of designated operator inspection reports are <br /> maintained on site. Submit copies of the missing reports to the EHD. <br /> This is a Class II violation. <br /> FA0004345 PR0231947 SCO01 04/11/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 Of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />