My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
24323
>
2300 - Underground Storage Tank Program
>
PR0231947
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:15 PM
Creation date
7/2/2021 4:13:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231947
PE
2361
FACILITY_ID
FA0004345
FACILITY_NAME
JAHANT FOOD N FUEL STOP
STREET_NUMBER
24323
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00516019
CURRENT_STATUS
01
SITE_LOCATION
24323 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAHANT FOOD N FUEL STOP 24323 N HWY 99 ACAMPO Aril 11 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 211 CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a DO. <br /> The most recent designated operator training was conducted on 3/28/18. The designated operator shall train facility <br /> employees for which he or she is responsible in the proper operation and maintenance of the UST system once every <br /> 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a Class II violation. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in UDC 16. If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. Immediately remove this liquid, make a hazardous waste determination <br /> per Title 22 hazardous waste regulations, and manage it accordingly. Ensure that all UDCs are maintained free of <br /> liquid. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> On the 8/29/18 Overfill Prevention Inspection Results for the mechanical flappers, the tank diameters are documented <br /> as smaller than the level at which the flappers are set to activate. Notification was provided to EHD for overfill <br /> prevention testing to be conducted on 4/11/19; no test results were found for this testing. <br /> All UST systems must be equipped with an approved, functional overfill prevention device at all times during fuel <br /> deliveries. The failed components must be repaired or replaced by a properly licensed, trained, and certified contractor <br /> under permit and inspection of the EHD. If the failed component can't be replaced immediately, there is a possibility <br /> that the 87, 89, 91 and diesel UST systems may be red tagged to prevent fuel inputs. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> The monitoring system certification was conducted on 4/11/19 and was not witnessed by EHD. Looked inside all <br /> sumps and diesel (truck side) UDCs. Verified sensor locations and piping communication. Verified spill bucket 5 <br /> gallon capacity. The paperwork inspection was conducted on 5/24/19. A complete inspection report was <br /> provided to the owner at that time. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by June 23, 2019. <br /> FA0004345 PR0231947 SCO01 04/11/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 7 Of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.