My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2008-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
17720
>
4400 - Solid Waste Program
>
PR0440058
>
CORRESPONDENCE_2008-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 2:12:56 PM
Creation date
7/16/2021 12:52:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2008-2009
RECORD_ID
PR0440058
PE
4433
FACILITY_ID
FA0004518
FACILITY_NAME
NORTH COUNTY LANDFILL
STREET_NUMBER
17720
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06512004
CURRENT_STATUS
01
SITE_LOCATION
17720 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I FIGURES <br />Figure 1 — Migration Monitoring Perimeter Boundary Site Map <br />Figure 2 — Triple Probe Soil Gas Monitoring Well <br />Figure 3 — Probe Detail -Triple Probe Soil Gas Monitoring Well <br />Figure 4 — Probe Installation Inside Well Enclosure <br />APPENDICES <br />Appendix A —Gas Monitoring Data Sheets <br />Appendix B — Well Logs (Existing Wells) <br />11 <br />CONTENTS <br />1.0 OBJECTIVE....................................................................................................................... 2 <br />2.0 BACKGROUND . • 2 <br />3.0 MONITORING PERIMETER NETWORK........................................................................... 2 <br />I. SOIL GAS WELL....................................................................................................................2 <br />A. Well Location . • 2 <br />B. Well Spacing...................................................................................................................2 <br />C. Well Depths.................................................................................................................... 3 <br />D. Well Construction............................................................................................................ 3 <br />E. Non -Perimeter Soil Gas Monitoring Wells.......................................................................3 <br />II. DESIGN CONSIDERATIONS............................................................................................3 <br />A. Local Soil And Rock Conditions...................................................................................... 4 <br />B. Hydrogeologic Conditions............................................................................................... 4 <br />C. Locations of Buildings and Structures Relative To The Migration MonitoringPerimeter... 4 <br />D. Adjacent Land Use and Inhabitable Structures Within 1000 feet of the disposal Site ...... 4 <br />E. Man -Made Pathways...................................................................................................... 4 <br />F. Nature, Age of Waste and Potential to Generate Landfill Gas(LFG)...............................4 <br />III. ON-SITE STRUCTURE MONITORING..............................................................................5 <br />A. Scale House Interior air: Electrical conduit entry point within the building ....................... 5 <br />B. Materials Recovery Facility Interior air: Interior of container loading dock wall (Wall) near <br />thebase of wall...................................................................................................................... 5 <br />C. Office and Maintenance Building Interior air: Electrical conduit entry point within lower <br />office....................................................................................... ............................................... 5 <br />D. Pump House Interior air: Electrical conduit entry point within lower office ....................... 5 <br />IV. MONITORING PROCEDURES..........................................................................................5 <br />A. Regulatory Limits............................................................................................................5 <br />B. Monitoring Methods........................................................................................................5 <br />C. Frequency.......................................................................................................................5 <br />D. Reporting........................................................................................................................ 6 <br />TABLES <br />Table 1 — Perimeter Monitoring Soil Gas Wells <br />Table 2 — Soil Gas Well Sampling Intervals <br />Table 3 — Soil Gas Wells - Depth <br />I FIGURES <br />Figure 1 — Migration Monitoring Perimeter Boundary Site Map <br />Figure 2 — Triple Probe Soil Gas Monitoring Well <br />Figure 3 — Probe Detail -Triple Probe Soil Gas Monitoring Well <br />Figure 4 — Probe Installation Inside Well Enclosure <br />APPENDICES <br />Appendix A —Gas Monitoring Data Sheets <br />Appendix B — Well Logs (Existing Wells) <br />11 <br />