Laserfiche WebLink
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY TRUCK AND AUTO STOP 3940 N TRACY BLVD,TRACY July 19, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 609 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC) Plan does not adequately discuss <br /> procedures for reporting a discharge.An incorrect phone number for Cal OES was listed in Appendix H and I in the <br /> SPCC Plan. <br /> REGULATION GUIDANCE: The SPCC plan shall include: (vi)Contact list and phone numbers for the facility <br /> response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br /> response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br /> described in § 112.1(b). <br /> (4)Unless you have submitted a response plan under§ 112.20, provide information and procedures in your Plan to <br /> enable a person reporting a discharge as described in § 112.1(b)to relate information on the exact address or <br /> location and phone number of the facility;the date and time of the discharge,the type of material discharged; <br /> estimates of the total quantity discharged; estimates of the quantity discharged as described in§ 112.1(b);the <br /> source of the discharge; a description of all affected media;the cause of the discharge; any damages or injuries <br /> caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge;whether an <br /> evacuation may be needed; and, the names of individuals and/or organizations who have also been contacted. <br /> CORRECTIVE ACTION: Immediately ensure the SPCC Plan includes the correct number for Cal OES <br /> (1-800-852-7550). Submit proof of correction to the EHD. <br /> This is a repeat violation, Class 11. <br /> 619 CFR 112.7(f)(1) Failed to train personnel on all discharge prevention details listed in this section. <br /> OBSERVATION: It appears that the oil handling personnel were not adequately trained, as required. Written records <br /> of monthly, annual, and HAZWOPER training as required by Section 3.5 of the SPCC Plan were not available for <br /> review during the inspection. <br /> REGULATION GUIDANCE: (f)(1)At a minimum,train your oil-handling personnel in the operation and maintenance <br /> of equipment to prevent discharges; discharge procedure protocols; applicable pollution control laws, rules, and <br /> regulations; general facility operations; and,the contents of the facility SPCC Plan. <br /> CORRECTIVE ACTION: Immediately provide adequate training to all oil handling personnel and submit a copy of <br /> the training log and training content to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0008057 PR0536557 SCO01 07/19/2021 <br /> EHD 28-01 Rev.9/16/2020 Page 7 of 9 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />