My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2800 - Aboveground Petroleum Storage Program
>
PR0516327
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 6:08:55 PM
Creation date
8/19/2021 8:45:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516327
PE
2832
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
01
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
571
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AdIkE <br /> '('able 2 <br /> Potential Releases Associated with ASTs <br /> Source volume Released Spill Rate Direction of Flow Fail-Safe Feature <br /> Complete Failure of Tank <br /> Tanks are double walled which meet the <br /> (2) Salvage/Used Oil Towards oil/water requirements of adequate sized secondary <br /> AST 1,000-gallons Instantaneous containment per CFR 1 I2.8(c)(2). Located <br /> separator <br /> (Double Walled) within building. Drains in the areas flow <br /> back to oil/water separators. <br /> Towards low spot <br /> r_:_:Eel FA1,000 gallons Instantancous within containment AST is located within a containment berm <br /> Fuel AST Fire Towards low spotPum 180 gallons Instantaneous AST is located within a containment bermwithin containmentel Fuel AST Towards Storm Water Onsite retention. General secondary <br /> containment is provided by the design of the <br /> Building D Fire 240 gallons Instantaneous Pond #7 <br /> Pum _ area. <br /> Diesel Fuel AST Towards low spot in Onsite retention. General secondary <br /> 140-195 gallons Instantaneous area or building floor. containment is provided by the design of the <br /> n <br /> Generator Tanks g area. <br /> Located within building. Drains in the areas <br /> Towards low spot in flow back to oil/water separators(See <br /> Biosol Mixing Tanks 100-200 galloons Instantaneous Biosol Mixing Room Proposed Schedule of Modifications at front <br /> of this Plan <br /> Tank Overfill i <br /> Tanks are double walled which meet the <br /> (2)Salvage/Used Oil requirements of adequate sized secondary <br /> Up to 10 Towards oil/water <br /> AST Up to 1,000 gallons containment per CFR 112.8(e)(2).Located <br /> (Double Walled) Gallons/Minute separator within building. Drains in the areas flow <br /> back to oil/water separators. <br /> i <br /> Up to l0 Towards low spot AST is located within a containment berm <br /> Diesel Fuel AST Up to 450 gallons Gallons/Minute within containment <br /> Diesel Fuel AST Fire Up to 100 gallons Up to 10 Towards low spot AST is located within a containment berm <br /> Pum Gallons/Minute within containment <br /> 18 Mavt 201 . <br />
The URL can be used to link to this page
Your browser does not support the video tag.