My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2800 - Aboveground Petroleum Storage Program
>
PR0516327
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 6:08:55 PM
Creation date
8/19/2021 8:45:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516327
PE
2832
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
01
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
571
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ 'fable 2 continued) <br /> Source Volume Released Spill Rate Direction of Flow Fail-Safe Feature <br /> Diesel Fuel AST Water retention. General secondary <br /> Up to 10 Towards Storm N niter containment isrovided b the design of the <br /> Building D Fire Up to 100 gallons Gallons/Minute Pond#7 p y <br /> Pum area. <br /> Onsite retention. General secondary <br /> Diesel Fuel AST Up to 10 Towards low spot in containment is provided b the design of the <br /> Generator Tanks Up to 200 gallons Gallons/Minute area or building floor. p y g <br /> area. <br /> Biosol Mixing Tanks Up to 100 gallons <br /> Up to 10 Towards low spot in Located within building. Drains in the areas <br /> Gallons/Minute Biosol Mixing Room flow back to oil/water separators <br /> Leaking Pipe or Valve <br /> Tanks are double walled which meet the <br /> (2) Salvage/Used Oil Towards oil/water requirements of adequate sized secondary <br /> AST Up to Several Gradual containment per CFR 1 12.8(c)(2). Located <br /> Gallons separator within building. Drains in the areas flow <br /> (Double Walled) <br /> back to oil/water separators. <br /> Up to Several Gradual Towards low spot AST is located within a containment berm <br /> Diesel Fuel AST Gallons within containment <br /> Diesel Fuel AST Fire U to Several Gradual Towards low spot <br /> Up AST is located within a containment berm <br /> Pum Gallons within containment <br /> Diesel Fuel AST Towards Storm Water Onsite retention. General secondary <br /> Up to Several Gradual containment is provided by the design of the <br /> Building D Fire Gallons Pond#7 <br /> Parea. <br /> Pump _ <br /> Onsite retention. General secondary <br /> Diesel Fuel AST Up to Several Gradual Towards low spot in containment is provided by the design of the <br /> Generator Tanks Gallons area or building floor. <br /> area. <br /> Up to Several Towards low spot in Located within building. Drains in the areas <br /> Biosol MixingTanks Gradual — <br /> Gallons Biosol Mixing Room clow back to oil/water separators <br /> C Tank Truck Leak or Failure <br /> Tanks are double walled which meet the <br /> (2)Salvage/Used Oil Gradual to Towards oil/water requirements of adequate sized secondary <br /> AST Up to 1,000 gallonscontainment per CFR 112.8(c)(2). Located <br /> Instantaneous separator <br /> (Double Walled) within buildings. Drains in the areas flow <br /> back to oil/water separator. <br /> Diesel Fuel AST Up to 1,000 gallons <br /> Gradual to Towards low spot AST is located within a containment berm <br /> Instantaneous within containment <br /> 19 kla�2017Au-,+P t-241-o <_ <br />
The URL can be used to link to this page
Your browser does not support the video tag.