COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2800 - Aboveground Petroleum Storage Program
>
PR0516327
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 6:08:55 PM
Creation date
8/19/2021 8:45:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516327
PE
2832
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
01
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
571
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mobile or Portable Oil Storage Containers -112.8 (c)(11) 01 <br />The drums and totes at this facility are located within buildings or containment areas. A <br />release from one or more of these containers would be quickly cleaned up. A catastrophic <br />release from several of these containers would flow to the oil/water separator located in the <br />lower level of the facility. <br />Transfer Operations, Pumping, and Facility Processes -40 CFR Part 112.8(d) <br />Buried Piping -112.8 (d)(1) <br />There are no buried pipes at the facility that contain/handle oils. The following belowgrade <br />transfer conduits are in place at the facility, but do not meet the buried pipe definition since <br />they are for the wastewater treatment system: concrete lined, as well as brick and mortar <br />lined open trenches, that lead to the oil/water separator. <br />Pipelines Not In Service -112.8 (d)(2) <br />When piping is not in service or on standby service for an extended period (over 3 months), <br />the terminal connection at the transfer point will be capped or blank flanged and marked as to <br />their origin. <br />Pipeline Supports -112.8 (d)(3) <br />Oil pipe supports are designed to minimize abrasion and corrosion and allow for expansion <br />and contraction. <br />Pipeline Inspections -112.8 (d)(4) <br />Aboveground oil pipelines and valves are examined monthly to assess the general condition <br />of flange joints, expansion joints, catch pans, pipeline supports, and locking of valves. <br />Written records of these inspections are kept on file with this Plan (see Appendix C for <br />Inspection Forms). <br />Warning Signs -112.8 (d)(5) <br />Some of the ASTs are located indoors out of the harm of vehicles that may endanger the <br />integrity of these oil storage containers. Therefore, there are no warning signs posted in the <br />vicinity of the indoor ASTs. The outdoor ASTs are located within containment berms with <br />concrete block walls out of the path of vehicle traffic. In addition, the transformers are <br />located behind locked fences. Therefore, vehicular traffic should not jeopardize the outdoor <br />ASTs or the transformers and warning signs are not necessary. <br />35 �Pvlav 2017,4iig�-b <br />