Laserfiche WebLink
This is a Class II Violation. <br />AUG 2 a `tulD <br />ENVIRONMENTAL <br />HEALTH DEPARTMENT <br />Owens' Response/Corrective Action for Items #609, 704, 706: <br />The facility intends to provide secondary containment for the 1,750 -gallon and <br />450 -gallon waste oil tanks. The facility is evaluating the following options for <br />correcting this item: retrofitting the existing tanks by placing a vessel inside the <br />existing tank to be a new primary (and the existing tank would be the secondary <br />containment), or replacing the tanks with double -walled tanks. <br />Item 710: CFR 112.8(c)(31(ivl Failed to maintain records of drainage from diked areas. <br />Records of drainage of uncontaminated rainwater from diked areas were not found on site. <br />Adequate records (or NPDES permit records) of drainage from diked areas shall be retained. <br />Immediately begin maintaining adequate records (or NPDES permit records) of drainage from <br />diked areas. Submit proof of correction to the EHD. <br />This is a minor violation. <br />Owens' Response/Corrective Action: • <br />There has been no drainage of rainwater from the diked areas on site; <br />accordingly, Owens has no drainage records. Owens will, however, create an <br />inspection record for use in the event we have a discharge. <br />Item 719: CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove <br />accumulations of.oil in diked areas. <br />Oily staining and standing oil were noted below the used oil tanks located in the vicinity of <br />the onsite oil/water separators. FUrthermare, the oil waterseparator,which was full of oily <br />liquid atthe time of inspection, is being used as a secondary containment for the 1,750 -gallon <br />used oil tank. Visible discharges which result in a loss of oil from a container, including but <br />not limited to seams, gaskets, piping, pumps, valves, rivets, and bolts, must be promptly <br />corrected. Immediately fix all leaks and clean all visible staining , and manage according to <br />the California Code of Regulations Title 22 hazardous waste regulations. Maintain all diked <br />areas free of all accumulations. Submit proof of correction to the EHD. <br />This is a Class I I violation. <br />Owens' Response/Corrective Action: <br />The facility intends to provide secondary containment for the 1,750 -gallon and <br />450 -gallon waste oil tanks. The facility is evaluating the following options for <br />correcting this item: retrofitting the existing tanks by placing a vessel inside the <br />f rl <br />